Descrição
What Is the DAXIN 3H3 160kVA 3/3 Phase Online UPS?
The DAXIN 3H3 160kVA is a low-frequency online UPS designed for high-capacity critical applications requiring three-phase input and three-phase output power protection.
Sua arquitetura trifásica 3/3 destina-se a instalações nas quais tanto o fornecimento de energia elétrica de entrada quanto as cargas críticas protegidas operam com energia trifásica.
The 3H3 Series uses online power-conversion architecture and supports display, alarm, protection, bypass, battery and communication functions according to the selected model and project configuration.
Typical applications include data centers, industrial facilities, power systems, transportation infrastructure, healthcare facilities and other large three-phase critical loads.
Principais benefícios
- 160kVA High-Capacity Power Protection: Designed for large three-phase critical loads and infrastructure applications.
- Arquitetura trifásica: Three-phase input and three-phase output match high-capacity three-phase electrical systems.
- Projeto de UPS de baixa frequência: Destinado a aplicações exigentes de proteção de energia nos setores industrial e de infraestrutura.
- Proteção de energia online: Supports continuous power conditioning for sensitive and mission-critical loads.
- Transferência da rede elétrica para a bateria em 0 ms: Maintains output during utility-to-battery transition according to the reference series specification.
- Sistema de bateria configurável: Battery configuration and runtime can be engineered according to load and backup-time requirements.
- System Monitoring and Protection: Display, alarms, protection and communication functions support operation and maintenance.
- Configuração baseada em projeto: É necessário verificar se a configuração selecionada possui recursos de paralelismo, redundância, desvio e comunicação.
O que significa “3/3 fases” em um no-break?
Um no-break trifásico 3/3 utiliza energia CA trifásica na entrada e fornece energia CA trifásica na saída.
This architecture is commonly used for high-capacity critical loads in data centers, industrial facilities, power infrastructure, healthcare systems and transportation applications.
The DAXIN 3H3 160kVA uses this three-phase input and three-phase output architecture for large critical-power applications.
Visões do produto e referência técnica

Aplicações típicas
- Large data centers and server facilities
- Industrial plants and manufacturing systems
- Power and utility infrastructure
- Telecom core facilities
- Hospitals and critical healthcare systems
- Transportation and tunnel infrastructure
- Commercial and public infrastructure
- Other high-capacity three-phase critical loads
How to Select a 160kVA Three-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.
No caso de um no-break trifásico (3/3), verifique se tanto a rede elétrica do local quanto as cargas críticas protegidas exigem alimentação trifásica.
Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communications and installation conditions for project configuration.
Perguntas frequentes
Esse produto pode ser configurado para um projeto específico?
Sim. A configuração elétrica, a autonomia da bateria, os sistemas de comunicação, o desvio, a disposição dos gabinetes e os acessórios do projeto podem ser analisados em função dos requisitos do local.
Todas as classificações técnicas são válidas para toda a série?
Não. As especificações e funções variam de acordo com o modelo e a configuração. Utilize a ficha técnica específica do projeto como referência definitiva.
A DAXIN ENERGY pode oferecer suporte na seleção de sistemas?
Sim. Forneça a lista de cargas, a fase e a tensão, o tempo de operação necessário, a meta de redundância, os requisitos de comunicação e o ambiente de instalação.
Solicitar uma configuração de projeto
Envie os dados de carga, o esquema unifilar, o tempo de backup necessário e as condições do local para receber uma proposta personalizada de UPS ou bateria.
What is the rated capacity of the DAXIN 3H3 160kVA?
The reference model is rated at 160kVA / 128kW.
O que significa “3/3 fases”?
It means the UPS uses three-phase input and supplies three-phase output.
Qual é o tempo de transição da rede elétrica para a bateria?
The supplied reference specification lists 0ms mains-to-battery transfer.
Qual é a tensão de saída compatível com o no-break?
A configuração de referência suporta saída trifásica de 380/400/415 VCA.
É possível personalizar a autonomia da bateria?
Battery configuration and runtime should be selected according to the connected load, required backup duration and approved system configuration.
Does the UPS support parallel or redundant operation?
Os recursos de paralelismo e redundância dependem da configuração selecionada e devem ser verificados em relação às especificações técnicas aprovadas antes do projeto do sistema.









Avaliações