Deskripsi
What Is the DAXIN 3H3 160kVA 3/3 Phase Online UPS?
The DAXIN 3H3 160kVA is a low-frequency online UPS designed for high-capacity critical applications requiring three-phase input and three-phase output power protection.
Arsitektur 3/3 fasa ini dirancang untuk fasilitas di mana baik pasokan listrik masuk maupun beban kritis yang dilindungi beroperasi pada sistem tiga fasa.
The 3H3 Series uses online power-conversion architecture and supports display, alarm, protection, bypass, battery and communication functions according to the selected model and project configuration.
Typical applications include data centers, industrial facilities, power systems, transportation infrastructure, healthcare facilities and other large three-phase critical loads.
Manfaat Utama
- 160kVA High-Capacity Power Protection: Designed for large three-phase critical loads and infrastructure applications.
- Arsitektur 3/3 Fase: Three-phase input and three-phase output match high-capacity three-phase electrical systems.
- Desain UPS Frekuensi Rendah: Dirancang untuk aplikasi perlindungan daya di sektor industri dan infrastruktur yang menuntut.
- Perlindungan Listrik Online: Supports continuous power conditioning for sensitive and mission-critical loads.
- Transfer dari Jaringan Listrik ke Baterai dalam 0 ms: Maintains output during utility-to-battery transition according to the reference series specification.
- Sistem Baterai yang Dapat Dikustomisasi: Battery configuration and runtime can be engineered according to load and backup-time requirements.
- System Monitoring and Protection: Display, alarms, protection and communication functions support operation and maintenance.
- Konfigurasi Berbasis Proyek: Kemampuan paralel, redundansi, bypass, dan komunikasi harus dipastikan untuk konfigurasi yang dipilih.
Apa Arti 3/3 Fase pada UPS?
UPS tiga fase 3/3 menggunakan daya AC tiga fase pada input dan menyalurkan daya AC tiga fase pada output.
This architecture is commonly used for high-capacity critical loads in data centers, industrial facilities, power infrastructure, healthcare systems and transportation applications.
The DAXIN 3H3 160kVA uses this three-phase input and three-phase output architecture for large critical-power applications.
Tampilan Produk dan Referensi Teknis

Aplikasi Umum
- Large data centers and server facilities
- Industrial plants and manufacturing systems
- Power and utility infrastructure
- Telecom core facilities
- Hospitals and critical healthcare systems
- Transportation and tunnel infrastructure
- Commercial and public infrastructure
- Other high-capacity three-phase critical loads
How to Select a 160kVA Three-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.
Untuk UPS 3/3 fase, pastikan bahwa baik sumber daya listrik di lokasi maupun beban kritis yang dilindungi memerlukan daya tiga fase.
Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communications and installation conditions for project configuration.
Pertanyaan yang Sering Diajukan
Apakah produk ini dapat disesuaikan untuk proyek tertentu?
Ya. Konfigurasi kelistrikan, masa pakai baterai, sistem komunikasi, jalur bypass, tata letak kabinet, dan perlengkapan proyek dapat dievaluasi sesuai dengan persyaratan lokasi.
Apakah semua peringkat teknis berlaku untuk seluruh seri?
Tidak. Peringkat dan fungsi bervariasi tergantung pada model dan konfigurasinya. Gunakan lembar spesifikasi teknis khusus proyek sebagai acuan akhir.
Apakah DAXIN ENERGY dapat membantu dalam pemilihan sistem?
Ya. Sampaikan daftar beban, fase dan tegangan, waktu operasional yang dibutuhkan, target redundansi, persyaratan komunikasi, serta lingkungan pemasangan.
Ajukan Permohonan Konfigurasi Proyek
Kirimkan data beban, diagram satu garis, waktu cadangan yang dibutuhkan, dan kondisi lokasi untuk mendapatkan penawaran UPS atau baterai yang disesuaikan dengan kebutuhan Anda.
What is the rated capacity of the DAXIN 3H3 160kVA?
The reference model is rated at 160kVA / 128kW.
Apa arti dari "3/3 fase"?
It means the UPS uses three-phase input and supplies three-phase output.
Berapa lama waktu yang dibutuhkan untuk mengalihkan daya dari jaringan listrik ke baterai?
The supplied reference specification lists 0ms mains-to-battery transfer.
Berapa tegangan keluaran yang didukung oleh UPS ini?
Konfigurasi referensi ini mendukung keluaran tiga fasa 380/400/415 VAC.
Can battery runtime be customized?
Battery configuration and runtime should be selected according to the connected load, required backup duration and approved system configuration.
Does the UPS support parallel or redundant operation?
Kemampuan paralel dan redundansi bergantung pada konfigurasi yang dipilih dan harus diverifikasi berdasarkan spesifikasi teknis yang telah disetujui sebelum perancangan sistem.









Ulasan
Belum ada ulasan.