Deskripsi
What Is the DAXIN HR33 10KL Rack/Tower Online UPS?
The DAXIN HR33 10KL is a high-frequency online UPS designed to provide conditioned backup power for critical electrical and electronic equipment while supporting flexible rack or tower installation.
Its rack/tower convertible architecture allows the UPS to adapt to different equipment-room layouts, including rack-based IT environments and floor-standing installations.
The HR33 10KL uses online double-conversion operation and supports digital control, LCD monitoring and project-configurable battery, communication, bypass and other system options according to the selected configuration.
Typical applications include data centers, server rooms, telecom facilities, network infrastructure, professional electronics and other critical loads requiring reliable online power protection.
Manfaat Utama
- Rack/Tower Convertible Design: Supports flexible installation in rack-based equipment rooms or tower configurations.
- Online Double-Conversion Operation: Provides conditioned output power for connected critical loads.
- High-Frequency UPS Architecture: Designed for professional critical-power applications with flexible deployment requirements.
- Digital Control and LCD Monitoring: Supports convenient UPS status monitoring and system operation.
- Configurable Battery Runtime: Battery configuration can be selected according to connected load and required backup duration.
- Communication Options: Monitoring and communication interfaces can be configured according to project requirements.
- Konfigurasi Berbasis Proyek: ECO, EPO, bypass, communications, parallel operation and other optional functions must be confirmed according to the selected configuration and approved technical specification.
What Is a Rack/Tower Convertible UPS?
A rack/tower convertible UPS is designed to support flexible installation in different equipment-room environments. Depending on the compatible mounting configuration, the UPS can be integrated into an equipment rack or deployed in a tower-style arrangement.
This flexibility is useful for server rooms, data centers, telecom facilities and professional IT environments where available space and equipment layouts may vary.
The DAXIN HR33 10KL applies this flexible installation concept to support different critical-power deployment requirements.
Mengapa Menggunakan UPS Konversi Ganda Online?
An online double-conversion UPS continuously supplies connected loads through the inverter, providing conditioned output power for sensitive and critical equipment.
This architecture is commonly used in applications where power continuity and output quality are important, including servers, network equipment, telecom systems and other professional electronic loads.
The appropriate UPS capacity, battery runtime and system configuration should be selected according to the actual connected load and project requirements.
Tampilan Produk dan Referensi Teknis

Aplikasi Umum
- Pusat data dan ruang server
- Telecom and communication facilities
- Network switches, servers and IT infrastructure
- Industrial control and automation equipment
- Sistem keamanan dan pemantauan
- Professional electronic equipment
- Critical rack-mounted equipment
- Floor-mounted critical power applications
How to Select the Right 10kVA Rack/Tower UPS
Select the UPS according to the actual connected load in kW and kVA, input and output phase, operating voltage, required backup time, battery configuration, installation orientation, bypass requirements and communication interfaces.
For rack installations, confirm rack dimensions, available installation space, ventilation and service clearances. For tower installations, confirm floor space, airflow and maintenance access.
Provide DAXIN ENERGY with the load list, site voltage, required runtime, rack or tower installation requirements, communication interfaces and installation environment to determine the appropriate UPS and battery configuration.
Pemilihan dan Perencanaan Proyek
Sebelum memesan, pastikan spesifikasi daya yang tepat, fase masukan/keluaran, tegangan, frekuensi, faktor daya, tegangan baterai, waktu operasional, fitur bypass, sistem komunikasi, dimensi, batas lingkungan, dan metode pemasangan sesuai dengan model yang dipilih serta gambar proyek.
Pertanyaan yang Sering Diajukan
Apakah produk ini dapat disesuaikan untuk proyek tertentu?
Ya. Konfigurasi kelistrikan, masa pakai baterai, sistem komunikasi, jalur bypass, tata letak kabinet, dan perlengkapan proyek dapat dievaluasi sesuai dengan persyaratan lokasi.
Apakah semua peringkat teknis berlaku untuk seluruh seri?
Tidak. Peringkat dan fungsi bervariasi tergantung pada model dan konfigurasinya. Gunakan lembar spesifikasi teknis khusus proyek sebagai acuan akhir.
Apakah DAXIN ENERGY dapat membantu dalam pemilihan sistem?
Ya. Sampaikan daftar beban, fase dan tegangan, waktu operasional yang dibutuhkan, target redundansi, persyaratan komunikasi, serta lingkungan pemasangan.
Ajukan Permohonan Konfigurasi Proyek
Kirimkan data beban, diagram satu garis, waktu cadangan yang dibutuhkan, dan kondisi lokasi untuk mendapatkan penawaran UPS atau baterai yang disesuaikan dengan kebutuhan Anda.
Can the HR33 10KL be installed in a rack or tower configuration?
The HR33 10KL is designed for flexible rack or tower installation according to the compatible mounting configuration and project requirements.
Is the HR33 10KL an online double-conversion UPS?
Yes. The product uses online double-conversion operation for conditioned critical-load power protection.
Can the battery runtime be customized?
Battery runtime depends on connected load, battery configuration and required backup duration. Long-runtime configurations can be reviewed according to project requirements.
Does the HR33 10KL support remote monitoring?
Communication and remote-monitoring options should be selected according to the HR33 10KL configuration and confirmed in the approved technical specification.