Onduleur en ligne de 10 kVA, modèle rack/tour | DAXIN HR33

The DAXIN HR33 10KL is a high-frequency online UPS with flexible rack or tower installation for critical power applications. Featuring online double-conversion topology, digital control, LCD monitoring and configurable battery and communication options, it is designed for data centers, server rooms, telecom infrastructure, professional electronics and other critical loads. Final electrical ratings and optional functions are subject to the approved HR33 10KL technical configuration.

Obtenir un devis et une assistance technique

Envoyez-nous votre demande, les quantités souhaitées et vos spécifications techniques. Notre équipe d'ingénieurs vous proposera une configuration adaptée.

Description

What Is the DAXIN HR33 10KL Rack/Tower Online UPS?

The DAXIN HR33 10KL is a high-frequency online UPS designed to provide conditioned backup power for critical electrical and electronic equipment while supporting flexible rack or tower installation.

Its rack/tower convertible architecture allows the UPS to adapt to different equipment-room layouts, including rack-based IT environments and floor-standing installations.

The HR33 10KL uses online double-conversion operation and supports digital control, LCD monitoring and project-configurable battery, communication, bypass and other system options according to the selected configuration.

Typical applications include data centers, server rooms, telecom facilities, network infrastructure, professional electronics and other critical loads requiring reliable online power protection.

Principaux avantages

    • Rack/Tower Convertible Design: Supports flexible installation in rack-based equipment rooms or tower configurations.
    • Online Double-Conversion Operation: Provides conditioned output power for connected critical loads.
    • High-Frequency UPS Architecture: Designed for professional critical-power applications with flexible deployment requirements.
    • Digital Control and LCD Monitoring: Supports convenient UPS status monitoring and system operation.
    • Configurable Battery Runtime: Battery configuration can be selected according to connected load and required backup duration.
    • Communication Options: Monitoring and communication interfaces can be configured according to project requirements.
    • Configuration par projet : ECO, EPO, bypass, communications, parallel operation and other optional functions must be confirmed according to the selected configuration and approved technical specification.

What Is a Rack/Tower Convertible UPS?

A rack/tower convertible UPS is designed to support flexible installation in different equipment-room environments. Depending on the compatible mounting configuration, the UPS can be integrated into an equipment rack or deployed in a tower-style arrangement.

This flexibility is useful for server rooms, data centers, telecom facilities and professional IT environments where available space and equipment layouts may vary.

The DAXIN HR33 10KL applies this flexible installation concept to support different critical-power deployment requirements.

Why Use an Online Double-Conversion UPS?

An online double-conversion UPS continuously supplies connected loads through the inverter, providing conditioned output power for sensitive and critical equipment.

This architecture is commonly used in applications where power continuity and output quality are important, including servers, network equipment, telecom systems and other professional electronic loads.

The appropriate UPS capacity, battery runtime and system configuration should be selected according to the actual connected load and project requirements.

Présentations des produits et documentation technique

Fiche produit de l'onduleur DAXIN HR33 10KL haute fréquence, convertible en version rack ou tour.

DAXIN HR33-10KL Online UPS Technical Specifications
Technical specifications for the DAXIN HR33-10KL online UPS.

Applications typiques

  • Centres de données et salles de serveurs
  • Telecom and communication facilities
  • Network switches, servers and IT infrastructure
  • Équipements de contrôle et d'automatisation industriels
  • Systèmes de sécurité et de surveillance
  • Professional electronic equipment
  • Critical rack-mounted equipment
  • Floor-mounted critical power applications

How to Select the Right 10kVA Rack/Tower UPS

Select the UPS according to the actual connected load in kW and kVA, input and output phase, operating voltage, required backup time, battery configuration, installation orientation, bypass requirements and communication interfaces.

For rack installations, confirm rack dimensions, available installation space, ventilation and service clearances. For tower installations, confirm floor space, airflow and maintenance access.

Provide DAXIN ENERGY with the load list, site voltage, required runtime, rack or tower installation requirements, communication interfaces and installation environment to determine the appropriate UPS and battery configuration.

Sélection et planification du projet

Avant de passer commande, vérifiez que la puissance nominale exacte, la phase d'entrée/sortie, la tension, la fréquence, le facteur de puissance, la tension de la batterie, l'autonomie, le contournement, les communications, les dimensions, les limites environnementales et la méthode d'installation correspondent bien au modèle sélectionné et aux plans du projet.

Foire aux questions

Ce produit peut-il être configuré pour un projet spécifique ?

Oui. La configuration électrique, l'autonomie de la batterie, les systèmes de communication, le contournement, la disposition des armoires et les accessoires du projet peuvent être examinés en fonction des exigences du site.

Les notes techniques sont-elles toutes communes à l'ensemble de la série ?

Non. Les caractéristiques techniques et les fonctions varient selon le modèle et la configuration. Veuillez vous référer à la fiche technique spécifique au projet comme référence définitive.

DAXIN ENERGY peut-elle vous aider à choisir un système ?

Oui. Veuillez nous fournir la liste des charges, la phase et la tension, la durée de fonctionnement requise, l'objectif de redondance, les exigences en matière de communication et l'environnement d'installation.

Demander une configuration de projet

Envoyez-nous les données de charge, le schéma unifilaire, le temps de secours requis et les conditions sur site afin de recevoir une proposition sur mesure concernant un onduleur ou une batterie.

Can the HR33 10KL be installed in a rack or tower configuration?

The HR33 10KL is designed for flexible rack or tower installation according to the compatible mounting configuration and project requirements.

Is the HR33 10KL an online double-conversion UPS?

Yes. The product uses online double-conversion operation for conditioned critical-load power protection.

Est-il possible de personnaliser l'autonomie de la batterie ?

Battery runtime depends on connected load, battery configuration and required backup duration. Long-runtime configurations can be reviewed according to project requirements.

Does the HR33 10KL support remote monitoring?

Communication and remote-monitoring options should be selected according to the HR33 10KL configuration and confirmed in the approved technical specification.

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “10kVA Rack/Tower Online UPS | DAXIN HR33”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *