Description
What Is the DAXIN 3H3 160kVA 3/3 Phase Online UPS?
The DAXIN 3H3 160kVA is a low-frequency online UPS designed for high-capacity critical applications requiring three-phase input and three-phase output power protection.
Son architecture triphasée 3/3 est destinée aux installations dans lesquelles tant l'alimentation électrique entrante que les charges critiques protégées fonctionnent en courant triphasé.
The 3H3 Series uses online power-conversion architecture and supports display, alarm, protection, bypass, battery and communication functions according to the selected model and project configuration.
Typical applications include data centers, industrial facilities, power systems, transportation infrastructure, healthcare facilities and other large three-phase critical loads.
Principaux avantages
- 160kVA High-Capacity Power Protection: Designed for large three-phase critical loads and infrastructure applications.
- Architecture triphasée : Three-phase input and three-phase output match high-capacity three-phase electrical systems.
- Conception d'un onduleur à basse fréquence : Conçu pour les applications exigeantes de protection de l'alimentation électrique dans les secteurs de l'industrie et des infrastructures.
- Protection de l'alimentation électrique en ligne : Supports continuous power conditioning for sensitive and mission-critical loads.
- Transfert du réseau électrique à la batterie en 0 ms : Maintains output during utility-to-battery transition according to the reference series specification.
- Système de batterie configurable : Battery configuration and runtime can be engineered according to load and backup-time requirements.
- System Monitoring and Protection: Display, alarms, protection and communication functions support operation and maintenance.
- Configuration par projet : Il convient de vérifier les capacités de fonctionnement en parallèle, de redondance, de contournement et de communication pour la configuration choisie.
Que signifie « 3/3 phases » dans un onduleur ?
Un onduleur triphasé 3/3 utilise une alimentation triphasée en courant alternatif en entrée et fournit une alimentation triphasée en courant alternatif en sortie.
This architecture is commonly used for high-capacity critical loads in data centers, industrial facilities, power infrastructure, healthcare systems and transportation applications.
The DAXIN 3H3 160kVA uses this three-phase input and three-phase output architecture for large critical-power applications.
Présentations des produits et documentation technique

Applications typiques
- Large data centers and server facilities
- Industrial plants and manufacturing systems
- Power and utility infrastructure
- Telecom core facilities
- Hospitals and critical healthcare systems
- Transportation and tunnel infrastructure
- Commercial and public infrastructure
- Other high-capacity three-phase critical loads
How to Select a 160kVA Three-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.
Pour un onduleur triphasé 3/3, vérifiez que l'alimentation électrique du site et les charges critiques à protéger nécessitent toutes deux une alimentation triphasée.
Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communications and installation conditions for project configuration.
Foire aux questions
Ce produit peut-il être configuré pour un projet spécifique ?
Oui. La configuration électrique, l'autonomie de la batterie, les systèmes de communication, le contournement, la disposition des armoires et les accessoires du projet peuvent être examinés en fonction des exigences du site.
Les notes techniques sont-elles toutes communes à l'ensemble de la série ?
Non. Les caractéristiques techniques et les fonctions varient selon le modèle et la configuration. Veuillez vous référer à la fiche technique spécifique au projet comme référence définitive.
DAXIN ENERGY peut-elle vous aider à choisir un système ?
Oui. Veuillez nous fournir la liste des charges, la phase et la tension, la durée de fonctionnement requise, l'objectif de redondance, les exigences en matière de communication et l'environnement d'installation.
Demander une configuration de projet
Envoyez-nous les données de charge, le schéma unifilaire, le temps de secours requis et les conditions sur site afin de recevoir une proposition sur mesure concernant un onduleur ou une batterie.
What is the rated capacity of the DAXIN 3H3 160kVA?
The reference model is rated at 160kVA / 128kW.
Que signifie « 3/3 phases » ?
It means the UPS uses three-phase input and supplies three-phase output.
Quel est le temps de basculement du réseau électrique vers la batterie ?
La fiche technique fournie indique un temps de transfert du réseau vers la batterie de 0 ms.
Quelle tension de sortie l'onduleur prend-il en charge ?
La configuration de référence prend en charge une sortie triphasée de 380/400/415 V CA.
Can battery runtime be customized?
Battery configuration and runtime should be selected according to the connected load, required backup duration and approved system configuration.
Does the UPS support parallel or redundant operation?
Les capacités de fonctionnement en parallèle et de redondance dépendent de la configuration choisie et doivent être vérifiées au regard du cahier des charges technique approuvé avant la conception du système.









Avis
Il n’y a pas encore d’avis.