UPS online de alta frequência para montagem em rack, 1-10 kVA | DAXIN

The DAXIN H1KR is a compact high-frequency online UPS designed for rack deployment and protected power delivery to critical electronic loads.

Solicite um orçamento e suporte técnico

Envie sua solicitação, a quantidade e os requisitos técnicos. Nossa equipe de engenharia entrará em contato com uma configuração adequada.

Descrição

Este no-break é adequado para o seu projeto?

The DAXIN 1kVA rack-mount online UPS provides compact double-conversion protection for 19-inch rack equipment, network devices and small server installations.

Its rack format preserves floor space and places protected power close to the supported IT or communications equipment.

Aplicações típicas

  • Network racks and edge servers
  • Security and surveillance systems
  • Equipamentos de telecomunicações
  • Laboratory and control racks

O que verificar antes de fazer o pedido

  • Rack depth and available U space
  • Load in watts and power factor
  • Standard battery or extended runtime
  • Input plug, output sockets and monitoring interface

Perguntas frequentes

Como devo escolher a capacidade do no-break?

Comece pela carga contínua medida, pela demanda de partida ou de pico e pela expansão prevista. A DAXIN ENERGY pode analisar a lista de cargas e recomendar uma margem operacional prática.

Como é determinada a autonomia da bateria?

O tempo de funcionamento depende da carga, da tensão da bateria, da capacidade da bateria, da idade da bateria, da temperatura e da eficiência do inversor. Informe a duração necessária do tempo de reserva e a carga normal para que possamos fazer o cálculo do projeto.

Este no-break pode funcionar com um gerador ou com um sistema de monitoramento remoto?

A compatibilidade entre o gerador e o sistema de monitoramento depende do modelo e da configuração selecionados. Verifique a capacidade do gerador, a estabilidade de frequência e as interfaces RS-232, RS-485, USB, Modbus ou SNMP necessárias antes de fazer o pedido.

Solicitar uma configuração de projeto

Envie à DAXIN ENERGY a lista de cargas, a tensão no local, o tempo de operação necessário, o ambiente de instalação e os requisitos de comunicação e redundância. A configuração final está sujeita à proposta técnica aprovada.

Vídeo do produto UPS de alta frequência da DAXIN

Assista à demonstração do produto para conhecer o formato do no-break, a interface operacional e o posicionamento da aplicação. A configuração elétrica final está sujeita à proposta técnica aprovada.

Série H1KR(L)-H10KR(L) de UPS online de alta frequência para montagem em rack, ideal para aplicações industriais

Série H1KR(L)-H10KR(L) de UPS online de alta frequência para montagem em rack, ideal para aplicações industriais – DAXIN ENERGY.

What Is the DAXIN H1KR High-Frequency Rack-Mount UPS?

The DAXIN H1KR is a compact high-frequency online UPS designed for rack deployment and protected power delivery to critical electronic loads.

Product View for DAXIN H1KR High-Frequency Rack-Mount UPS.

Principais benefícios

  • A arquitetura de conversão de energia online oferece proteção contínua contra sobrecargas.
  • O formato de montagem em rack aproveita o espaço do gabinete de equipamentos de maneira eficiente.
  • As informações operacionais exibidas no LCD permitem a verificação do status local.
  • As opções de gerador, comunicação, derivação e bateria dependem do modelo selecionado.
  • O design compacto é adequado para implantações distribuídas com carga crítica.

Visões do produto e referência técnica

Product View for DAXIN H1KR High-Frequency Rack-Mount UPS.
Alternate Product View for DAXIN H1KR High-Frequency Rack-Mount UPS.
Rear or Side View for DAXIN H1KR High-Frequency Rack-Mount UPS.
ItemH1KR(L)H2KR(L)H3KR(L)H6KR(L)H10KR(L)
ModeloH1KR(L)H2KR(L)H3KR(L)H6KR(L)H10KR(L)
Capacidade1kVA/0.8kW2kVA/1.6kW3kVA/2.4kW6kVA/6kW10kVA/10kW
Entrada
Faixa de tensão

Min Transfer Voltage

Min Original Voltage

Max Original Voltage

180VAC/160VAC/140VAC/120VAC±5% (Ambient Temp<35℃)

(Load:100%‑80% /80%‑70% /70‑60% /60‑0%)

195VAC/175VAC/155VAC/135VAC±5% (Ambient Temp<35℃)

(Load:100%‑80% /80%‑70% /70‑60% /60‑0%)

300 VCA ±51 TP3T

290 VCA ±51 TP3T

180VAC/160VAC/140VAC/120VAC±5% (Ambient Temp<35℃)

(Load:100%‑80% /80%‑70% /70‑60% /60‑0%)

195VAC/175VAC/155VAC/135VAC±5% (Ambient Temp<35℃)

(Load:100%‑80% /80%‑70% /70‑60% /60‑0%)

300 VCA ±51 TP3T

290 VCA ±51 TP3T

180VAC/160VAC/140VAC/120VAC±5% (Ambient Temp<35℃)

(Load:100%‑80% /80%‑70% /70‑60% /60‑0%)

195VAC/175VAC/155VAC/135VAC±5% (Ambient Temp<35℃)

(Load:100%‑80% /80%‑70% /70‑60% /60‑0%)

300 VCA ±51 TP3T

290 VCA ±51 TP3T

110‑300VAC ±3% @60% load

176‑300VAC ±3% @100% load

Tensão mínima de transferência +10 V

300 VCA ±31 TP3T

Max transfer voltage‑10V

110‑300VAC ±3% @60% load

176‑300VAC ±3% @100% load

Tensão mínima de transferência +10 V

300 VCA ±31 TP3T

Max transfer voltage‑10V

Faixa de frequência40Hz‑70Hz40Hz‑70Hz40Hz‑70Hz46‑54Hz@50Hz system; 56‑64Hz@60Hz system46‑54Hz@50Hz system; 56‑64Hz@60Hz system
FaseSingle‑phase groundedSingle‑phase groundedSingle‑phase groundedSingle‑phase groundedSingle‑phase grounded
Fator de potência≥0.99 @220‑230VAC (input voltage)≥0.99 @220‑230VAC (input voltage)≥0.99 @220‑230VAC (input voltage)N/AN/A
Saída
Tensão de saída208/220/230/240 VCA208/220/230/240 VCA208/220/230/240 VCA208/220/230/240 VCA208/220/230/240 VCA
AC Voltage Range±1% (Battery Mode)±1% (Battery Mode)±1% (Battery Mode)±1% (Battery Mode)±1% (Battery Mode)
Frequency Range (Sync Range)47‑53Hz or 57‑63Hz47‑53Hz or 57‑63Hz47‑53Hz or 57‑63Hz46‑54Hz@50Hz system; 56‑64Hz@60Hz system46‑54Hz@50Hz system; 56‑64Hz@60Hz system
Faixa de frequência (modo de bateria)50Hz±0.25Hz or 60Hz±0.3Hz50Hz±0.25Hz or 60Hz±0.3Hz50Hz±0.25Hz or 60Hz±0.3Hz50Hz±0.1Hz or 60Hz±0.1Hz50Hz±0.1Hz or 60Hz±0.1Hz
OverloadAmbient temp<35℃:105‑110%:10min; UPS auto‑restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110‑130%:30s auto‑shutdown in battery mode; transfer to bypass with normal input.>130%:UPS auto‑shutdown in battery mode; transfer to bypass with normal input.>150%:Instant protectionAmbient temp<35℃:105‑110%:10min; UPS auto‑restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110‑130%:30s auto‑shutdown in battery mode; transfer to bypass with normal input.>130%:UPS auto‑shutdown in battery mode; transfer to bypass with normal input.>150%:Instant protectionAmbient temp<35℃:105‑110%:10min; UPS auto‑restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110‑130%:30s auto‑shutdown in battery mode; transfer to bypass with normal input.>130%:UPS auto‑shutdown in battery mode; transfer to bypass with normal input.>150%:Instant protection100‑110%:30min; 110‑130%:5min; >130%:10s100‑110%:30min; 110‑130%:5min; >130%:10s
Current Crest Factor3:13:13:13:13:1
THD≤3% THD (linear load); ≤6% THD (non‑linear load)≤3% THD (linear load); ≤6% THD (non‑linear load)≤3% THD (linear load); ≤6% THD (non‑linear load)≤1% @100% (linear load); ≤4% @100% (non‑linear load)≤1% @100% (linear load); ≤4% @100% (non‑linear load)
Tempo de transferência

Da rede elétrica para a bateria

Do inversor para o bypass

4 ms (condições padrão)

Onda senoidal pura

4 ms (condições padrão)

Onda senoidal pura

4 ms (condições padrão)

Onda senoidal pura

0 ms

N/A

0 ms

N/A

Forma de onda (Modo bateria)Onda senoidal puraOnda senoidal puraOnda senoidal puraN/AN/A
Eficiência
Modo AC88%89%90%>95% (Max)>95% (Max)
Modo de bateria83%85%88%>93% (Max)>93% (Max)
Battery — Standard Model
Modelo da bateria12V/7AH12V/7AH12V/7AH12V/7AH12V/9AH
Quantidade de baterias2461616
Corrente de carga1A1A1A1A±10% (Default)1A±10% (Default)
Battery — Long‑run Model
Modelo da bateriaSubject to supplierSubject to supplierSubject to supplierSubject to applicationSubject to application
Quantidade de baterias36816‑2016‑20
Corrente de carga1A/2A/4A/6A1A/2A/4A/6A1A/2A/4A/6A2A±10% (Default); Optional:1A/2A/4A/6A/8A2A±10% (Default); Optional:1A/2A/4A/6A/8A
Physical Performance — Standard Model
Dimensão: P × L × A (mm)310×438×88410×438×88630×438×88UPS:509×438×88 [2U]

Battery Pack:688×438×88 [2U]

UPS:509×438×88 [2U]

Battery Pack:688×438×88 [2U]

Peso líquido (kg)121929.3UPS:11; Battery Pack:48UPS:12.1; Battery Pack:53
Physical Performance — Long‑run Model
Dimensão: P × L × A (mm)310×438×88410×438×88410×438×88530×438×88 [2U]580×438×133 [3U]
Peso líquido (kg)91214.21112.1
Ambiente operacional
Umidade de operação20‑90% RH @0‑40℃ (Non‑condensing)20‑90% RH @0‑40℃ (Non‑condensing)20‑90% RH @0‑40℃ (Non‑condensing)<95% & non‑condensing<95% & non‑condensing
Ruído<50dB@1 Meter<50dB@1 Meter<50dB@1 Meter<55dB@1 Meter<58dB@1 Meter
Temperatura de operaçãoN/AN/AN/A0‑40℃ (Battery life shortens above 25℃)0‑40℃ (Battery life shortens above 25℃)
Max Operating AltitudeN/AN/AN/A<1000m**<1000m**
Controle e Gestão
Intelligent RS‑232/USBSupport Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MACSupport Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MACSupport Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MACSupport Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MACSupport Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC
SNMP opcionalPower management via SNMP manager and web browserPower management via SNMP manager and web browserPower management via SNMP manager and web browserPower management via SNMP manager and web browserPower management via SNMP manager and web browser

Footer Note:
As especificações estão sujeitas a alterações sem aviso prévio.

Technical Reference for DAXIN H1KR High-Frequency Rack-Mount UPS.

Aplicações típicas

Gabinetes de servidores, salas de rede, sistemas de telecomunicações, equipamentos de segurança, setor financeiro, educação e cargas de TI distribuídas.

Seleção e Planejamento do Projeto

Antes de fazer o pedido, verifique se a potência nominal exata, a fase de entrada/saída, a tensão, a frequência, o fator de potência, a tensão da bateria, o tempo de operação, o bypass, os recursos de comunicação, as dimensões, os limites ambientais e o método de instalação correspondem ao modelo selecionado e aos desenhos do projeto.

Perguntas frequentes

Esse produto pode ser configurado para um projeto específico?

Sim. A configuração elétrica, a autonomia da bateria, os sistemas de comunicação, o desvio, a disposição dos gabinetes e os acessórios do projeto podem ser analisados em função dos requisitos do local.

Todas as classificações técnicas são válidas para toda a série?

Não. As especificações e funções variam de acordo com o modelo e a configuração. Utilize a ficha técnica específica do projeto como referência definitiva.

A DAXIN ENERGY pode oferecer suporte na seleção de sistemas?

Sim. Forneça a lista de cargas, a fase e a tensão, o tempo de operação necessário, a meta de redundância, os requisitos de comunicação e o ambiente de instalação.

Solicitar uma configuração de projeto

Envie os dados de carga, o esquema unifilar, o tempo de backup necessário e as condições do local para receber uma proposta personalizada de UPS ou bateria.

DAXIN ENERGY UPS Power Solution Provider for Data Centers and Industrial Applications
UPS Power Solution Provider – DAXIN ENERGY

Avaliações

Não há avaliações ainda.

Seja o primeiro a avaliar “High-Frequency Rack-Mount Online UPS 1-10kVA | DAXIN”

O seu endereço de e-mail não será publicado. Campos obrigatórios são marcados com *