Descrição
Este no-break é adequado para o seu projeto?
The DAXIN 1kVA rack-mount online UPS provides compact double-conversion protection for 19-inch rack equipment, network devices and small server installations.
Its rack format preserves floor space and places protected power close to the supported IT or communications equipment.
Aplicações típicas
- Network racks and edge servers
- Security and surveillance systems
- Equipamentos de telecomunicações
- Laboratory and control racks
O que verificar antes de fazer o pedido
- Rack depth and available U space
- Load in watts and power factor
- Standard battery or extended runtime
- Input plug, output sockets and monitoring interface
Perguntas frequentes
Como devo escolher a capacidade do no-break?
Comece pela carga contínua medida, pela demanda de partida ou de pico e pela expansão prevista. A DAXIN ENERGY pode analisar a lista de cargas e recomendar uma margem operacional prática.
Como é determinada a autonomia da bateria?
O tempo de funcionamento depende da carga, da tensão da bateria, da capacidade da bateria, da idade da bateria, da temperatura e da eficiência do inversor. Informe a duração necessária do tempo de reserva e a carga normal para que possamos fazer o cálculo do projeto.
Este no-break pode funcionar com um gerador ou com um sistema de monitoramento remoto?
A compatibilidade entre o gerador e o sistema de monitoramento depende do modelo e da configuração selecionados. Verifique a capacidade do gerador, a estabilidade de frequência e as interfaces RS-232, RS-485, USB, Modbus ou SNMP necessárias antes de fazer o pedido.
Solicitar uma configuração de projeto
Envie à DAXIN ENERGY a lista de cargas, a tensão no local, o tempo de operação necessário, o ambiente de instalação e os requisitos de comunicação e redundância. A configuração final está sujeita à proposta técnica aprovada.
Vídeo do produto UPS de alta frequência da DAXIN
Assista à demonstração do produto para conhecer o formato do no-break, a interface operacional e o posicionamento da aplicação. A configuração elétrica final está sujeita à proposta técnica aprovada.
Série H1KR(L)-H10KR(L) de UPS online de alta frequência para montagem em rack, ideal para aplicações industriais
What Is the DAXIN H1KR High-Frequency Rack-Mount UPS?
The DAXIN H1KR is a compact high-frequency online UPS designed for rack deployment and protected power delivery to critical electronic loads.
Principais benefícios
- A arquitetura de conversão de energia online oferece proteção contínua contra sobrecargas.
- O formato de montagem em rack aproveita o espaço do gabinete de equipamentos de maneira eficiente.
- As informações operacionais exibidas no LCD permitem a verificação do status local.
- As opções de gerador, comunicação, derivação e bateria dependem do modelo selecionado.
- O design compacto é adequado para implantações distribuídas com carga crítica.
Visões do produto e referência técnica
| Item | H1KR(L) | H2KR(L) | H3KR(L) | H6KR(L) | H10KR(L) |
|---|---|---|---|---|---|
| Modelo | H1KR(L) | H2KR(L) | H3KR(L) | H6KR(L) | H10KR(L) |
| Capacidade | 1kVA/0.8kW | 2kVA/1.6kW | 3kVA/2.4kW | 6kVA/6kW | 10kVA/10kW |
| Entrada | |||||
| Faixa de tensão Min Transfer Voltage Min Original Voltage Max Original Voltage | 180VAC/160VAC/140VAC/120VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 195VAC/175VAC/155VAC/135VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 300 VCA ±51 TP3T 290 VCA ±51 TP3T | 180VAC/160VAC/140VAC/120VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 195VAC/175VAC/155VAC/135VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 300 VCA ±51 TP3T 290 VCA ±51 TP3T | 180VAC/160VAC/140VAC/120VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 195VAC/175VAC/155VAC/135VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 300 VCA ±51 TP3T 290 VCA ±51 TP3T | 110‑300VAC ±3% @60% load 176‑300VAC ±3% @100% load Tensão mínima de transferência +10 V 300 VCA ±31 TP3T Max transfer voltage‑10V | 110‑300VAC ±3% @60% load 176‑300VAC ±3% @100% load Tensão mínima de transferência +10 V 300 VCA ±31 TP3T Max transfer voltage‑10V |
| Faixa de frequência | 40Hz‑70Hz | 40Hz‑70Hz | 40Hz‑70Hz | 46‑54Hz@50Hz system; 56‑64Hz@60Hz system | 46‑54Hz@50Hz system; 56‑64Hz@60Hz system |
| Fase | Single‑phase grounded | Single‑phase grounded | Single‑phase grounded | Single‑phase grounded | Single‑phase grounded |
| Fator de potência | ≥0.99 @220‑230VAC (input voltage) | ≥0.99 @220‑230VAC (input voltage) | ≥0.99 @220‑230VAC (input voltage) | N/A | N/A |
| Saída | |||||
| Tensão de saída | 208/220/230/240 VCA | 208/220/230/240 VCA | 208/220/230/240 VCA | 208/220/230/240 VCA | 208/220/230/240 VCA |
| AC Voltage Range | ±1% (Battery Mode) | ±1% (Battery Mode) | ±1% (Battery Mode) | ±1% (Battery Mode) | ±1% (Battery Mode) |
| Frequency Range (Sync Range) | 47‑53Hz or 57‑63Hz | 47‑53Hz or 57‑63Hz | 47‑53Hz or 57‑63Hz | 46‑54Hz@50Hz system; 56‑64Hz@60Hz system | 46‑54Hz@50Hz system; 56‑64Hz@60Hz system |
| Faixa de frequência (modo de bateria) | 50Hz±0.25Hz or 60Hz±0.3Hz | 50Hz±0.25Hz or 60Hz±0.3Hz | 50Hz±0.25Hz or 60Hz±0.3Hz | 50Hz±0.1Hz or 60Hz±0.1Hz | 50Hz±0.1Hz or 60Hz±0.1Hz |
| Overload | Ambient temp<35℃:105‑110%:10min; UPS auto‑restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110‑130%:30s auto‑shutdown in battery mode; transfer to bypass with normal input.>130%:UPS auto‑shutdown in battery mode; transfer to bypass with normal input.>150%:Instant protection | Ambient temp<35℃:105‑110%:10min; UPS auto‑restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110‑130%:30s auto‑shutdown in battery mode; transfer to bypass with normal input.>130%:UPS auto‑shutdown in battery mode; transfer to bypass with normal input.>150%:Instant protection | Ambient temp<35℃:105‑110%:10min; UPS auto‑restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110‑130%:30s auto‑shutdown in battery mode; transfer to bypass with normal input.>130%:UPS auto‑shutdown in battery mode; transfer to bypass with normal input.>150%:Instant protection | 100‑110%:30min; 110‑130%:5min; >130%:10s | 100‑110%:30min; 110‑130%:5min; >130%:10s |
| Current Crest Factor | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 |
| THD | ≤3% THD (linear load); ≤6% THD (non‑linear load) | ≤3% THD (linear load); ≤6% THD (non‑linear load) | ≤3% THD (linear load); ≤6% THD (non‑linear load) | ≤1% @100% (linear load); ≤4% @100% (non‑linear load) | ≤1% @100% (linear load); ≤4% @100% (non‑linear load) |
| Tempo de transferência Da rede elétrica para a bateria Do inversor para o bypass | 4 ms (condições padrão) Onda senoidal pura | 4 ms (condições padrão) Onda senoidal pura | 4 ms (condições padrão) Onda senoidal pura | 0 ms N/A | 0 ms N/A |
| Forma de onda (Modo bateria) | Onda senoidal pura | Onda senoidal pura | Onda senoidal pura | N/A | N/A |
| Eficiência | |||||
| Modo AC | 88% | 89% | 90% | >95% (Max) | >95% (Max) |
| Modo de bateria | 83% | 85% | 88% | >93% (Max) | >93% (Max) |
| Battery — Standard Model | |||||
| Modelo da bateria | 12V/7AH | 12V/7AH | 12V/7AH | 12V/7AH | 12V/9AH |
| Quantidade de baterias | 2 | 4 | 6 | 16 | 16 |
| Corrente de carga | 1A | 1A | 1A | 1A±10% (Default) | 1A±10% (Default) |
| Battery — Long‑run Model | |||||
| Modelo da bateria | Subject to supplier | Subject to supplier | Subject to supplier | Subject to application | Subject to application |
| Quantidade de baterias | 3 | 6 | 8 | 16‑20 | 16‑20 |
| Corrente de carga | 1A/2A/4A/6A | 1A/2A/4A/6A | 1A/2A/4A/6A | 2A±10% (Default); Optional:1A/2A/4A/6A/8A | 2A±10% (Default); Optional:1A/2A/4A/6A/8A |
| Physical Performance — Standard Model | |||||
| Dimensão: P × L × A (mm) | 310×438×88 | 410×438×88 | 630×438×88 | UPS:509×438×88 [2U] Battery Pack:688×438×88 [2U] | UPS:509×438×88 [2U] Battery Pack:688×438×88 [2U] |
| Peso líquido (kg) | 12 | 19 | 29.3 | UPS:11; Battery Pack:48 | UPS:12.1; Battery Pack:53 |
| Physical Performance — Long‑run Model | |||||
| Dimensão: P × L × A (mm) | 310×438×88 | 410×438×88 | 410×438×88 | 530×438×88 [2U] | 580×438×133 [3U] |
| Peso líquido (kg) | 9 | 12 | 14.2 | 11 | 12.1 |
| Ambiente operacional | |||||
| Umidade de operação | 20‑90% RH @0‑40℃ (Non‑condensing) | 20‑90% RH @0‑40℃ (Non‑condensing) | 20‑90% RH @0‑40℃ (Non‑condensing) | <95% & non‑condensing | <95% & non‑condensing |
| Ruído | <50dB@1 Meter | <50dB@1 Meter | <50dB@1 Meter | <55dB@1 Meter | <58dB@1 Meter |
| Temperatura de operação | N/A | N/A | N/A | 0‑40℃ (Battery life shortens above 25℃) | 0‑40℃ (Battery life shortens above 25℃) |
| Max Operating Altitude | N/A | N/A | N/A | <1000m** | <1000m** |
| Controle e Gestão | |||||
| Intelligent RS‑232/USB | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC |
| SNMP opcional | Power management via SNMP manager and web browser | Power management via SNMP manager and web browser | Power management via SNMP manager and web browser | Power management via SNMP manager and web browser | Power management via SNMP manager and web browser |
Footer Note:
As especificações estão sujeitas a alterações sem aviso prévio.
Aplicações típicas
Gabinetes de servidores, salas de rede, sistemas de telecomunicações, equipamentos de segurança, setor financeiro, educação e cargas de TI distribuídas.
Seleção e Planejamento do Projeto
Antes de fazer o pedido, verifique se a potência nominal exata, a fase de entrada/saída, a tensão, a frequência, o fator de potência, a tensão da bateria, o tempo de operação, o bypass, os recursos de comunicação, as dimensões, os limites ambientais e o método de instalação correspondem ao modelo selecionado e aos desenhos do projeto.
Perguntas frequentes
Esse produto pode ser configurado para um projeto específico?
Sim. A configuração elétrica, a autonomia da bateria, os sistemas de comunicação, o desvio, a disposição dos gabinetes e os acessórios do projeto podem ser analisados em função dos requisitos do local.
Todas as classificações técnicas são válidas para toda a série?
Não. As especificações e funções variam de acordo com o modelo e a configuração. Utilize a ficha técnica específica do projeto como referência definitiva.
A DAXIN ENERGY pode oferecer suporte na seleção de sistemas?
Sim. Forneça a lista de cargas, a fase e a tensão, o tempo de operação necessário, a meta de redundância, os requisitos de comunicação e o ambiente de instalação.
Solicitar uma configuração de projeto
Envie os dados de carga, o esquema unifilar, o tempo de backup necessário e as condições do local para receber uma proposta personalizada de UPS ou bateria.










Avaliações