Описание
Is This UPS Right for Your Project?
ИБП DAXIN мощностью 1 кВА с онлайн-режимом работы, предназначенный для монтажа в стойку, обеспечивает компактную защиту с двойным преобразованием для 19-дюймового стоечного оборудования, сетевых устройств и небольших серверных установок.
Its rack format preserves floor space and places protected power close to the supported IT or communications equipment.
Типичные области применения
- Network racks and edge servers
- Security and surveillance systems
- Telecom equipment
- Laboratory and control racks
Что необходимо уточнить перед оформлением заказа
- Rack depth and available U space
- Load in watts and power factor
- Standard battery or extended runtime
- Input plug, output sockets and monitoring interface
Часто задаваемые вопросы
How should I choose the UPS capacity?
Start with the measured continuous load, startup or peak demand and expected expansion. DAXIN ENERGY can review the load list and recommend a practical operating margin.
How is battery runtime determined?
Runtime depends on load, battery voltage, battery capacity, battery age, temperature and inverter efficiency. Share the required backup duration and normal load for a project calculation.
Can this UPS work with a generator or remote monitoring system?
Generator and monitoring compatibility depends on the selected model and configuration. Confirm generator capacity, frequency stability and the required RS-232, RS-485, USB, Modbus or SNMP interface before ordering.
Запросить конфигурацию проекта
Send DAXIN ENERGY the load list, site voltage, required runtime, installation environment, communications and redundancy requirements. The final configuration is subject to the approved technical proposal.
DAXIN High-Frequency UPS Product Video
Watch the product demonstration to review the UPS format, operating interface and application positioning. Final electrical configuration is subject to the approved technical proposal.
H1KR(L)-H10KR(L) Series High-Frequency Rackmount Online UPS Best For Industrial Applications
What Is the DAXIN H1KR High-Frequency Rack-Mount UPS?
The DAXIN H1KR is a compact high-frequency online UPS designed for rack deployment and protected power delivery to critical electronic loads.
Основные преимущества
- Архитектура преобразования электроэнергии в режиме онлайн обеспечивает непрерывную защиту нагрузки.
- Формат для монтажа в стойку позволяет эффективно использовать пространство в шкафу для оборудования.
- Информация на ЖК-дисплее позволяет отслеживать текущее состояние оборудования.
- Наличие генератора, средств связи, байпаса и аккумуляторных батарей зависит от выбранной модели.
- Компактная конструкция подходит для распределенных систем, работающих в условиях критической нагрузки.
Обзор продукции и техническая справка
| Пункт | H1KR(L) | H2KR(L) | H3KR(L) | H6KR(L) | H10KR(L) |
|---|---|---|---|---|---|
| Модель | H1KR(L) | H2KR(L) | H3KR(L) | H6KR(L) | H10KR(L) |
| Вместимость | 1kVA/0.8kW | 2kVA/1.6kW | 3kVA/2.4kW | 6kVA/6kW | 10kVA/10kW |
| Ввод | |||||
| Диапазон напряжения Min Transfer Voltage Min Original Voltage Max Original Voltage | 180VAC/160VAC/140VAC/120VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 195VAC/175VAC/155VAC/135VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 300VAC ±5% 290VAC ±5% | 180VAC/160VAC/140VAC/120VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 195VAC/175VAC/155VAC/135VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 300VAC ±5% 290VAC ±5% | 180VAC/160VAC/140VAC/120VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 195VAC/175VAC/155VAC/135VAC±5% (Ambient Temp<35℃) (Load:100%‑80% /80%‑70% /70‑60% /60‑0%) 300VAC ±5% 290VAC ±5% | 110‑300VAC ±3% @60% load 176‑300VAC ±3% @100% load Минимальное напряжение передачи +10 В 300VAC ±3% Max transfer voltage‑10V | 110‑300VAC ±3% @60% load 176‑300VAC ±3% @100% load Минимальное напряжение передачи +10 В 300VAC ±3% Max transfer voltage‑10V |
| Диапазон частот | 40Hz‑70Hz | 40Hz‑70Hz | 40Hz‑70Hz | 46‑54Hz@50Hz system; 56‑64Hz@60Hz system | 46‑54Hz@50Hz system; 56‑64Hz@60Hz system |
| Фаза | Single‑phase grounded | Single‑phase grounded | Single‑phase grounded | Single‑phase grounded | Single‑phase grounded |
| Коэффициент мощности | ≥0.99 @220‑230VAC (input voltage) | ≥0.99 @220‑230VAC (input voltage) | ≥0.99 @220‑230VAC (input voltage) | Н/Д | Н/Д |
| Вывод | |||||
| Выходное напряжение | 208/220/230/240 В переменного тока | 208/220/230/240 В переменного тока | 208/220/230/240 В переменного тока | 208/220/230/240 В переменного тока | 208/220/230/240 В переменного тока |
| AC Voltage Range | ±1% (Battery Mode) | ±1% (Battery Mode) | ±1% (Battery Mode) | ±1% (Battery Mode) | ±1% (Battery Mode) |
| Frequency Range (Sync Range) | 47‑53Hz or 57‑63Hz | 47‑53Hz or 57‑63Hz | 47‑53Hz or 57‑63Hz | 46‑54Hz@50Hz system; 56‑64Hz@60Hz system | 46‑54Hz@50Hz system; 56‑64Hz@60Hz system |
| Диапазон частот (режим работы от аккумулятора) | 50Hz±0.25Hz or 60Hz±0.3Hz | 50Hz±0.25Hz or 60Hz±0.3Hz | 50Hz±0.25Hz or 60Hz±0.3Hz | 50Hz±0.1Hz or 60Hz±0.1Hz | 50Hz±0.1Hz or 60Hz±0.1Hz |
| Overload | Ambient temp<35℃:105‑110%:10min; UPS auto‑restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110‑130%:30s auto‑shutdown in battery mode; transfer to bypass with normal input.>130%:UPS auto‑shutdown in battery mode; transfer to bypass with normal input.>150%:Instant protection | Ambient temp<35℃:105‑110%:10min; UPS auto‑restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110‑130%:30s auto‑shutdown in battery mode; transfer to bypass with normal input.>130%:UPS auto‑shutdown in battery mode; transfer to bypass with normal input.>150%:Instant protection | Ambient temp<35℃:105‑110%:10min; UPS auto‑restarts 10s after shutdown in battery mode; transfer to bypass with normal input. 110‑130%:30s auto‑shutdown in battery mode; transfer to bypass with normal input.>130%:UPS auto‑shutdown in battery mode; transfer to bypass with normal input.>150%:Instant protection | 100‑110%:30min; 110‑130%:5min; >130%:10s | 100‑110%:30min; 110‑130%:5min; >130%:10s |
| Current Crest Factor | 3:1 | 3:1 | 3:1 | 3:1 | 3:1 |
| THD | ≤3% THD (linear load); ≤6% THD (non‑linear load) | ≤3% THD (linear load); ≤6% THD (non‑linear load) | ≤3% THD (linear load); ≤6% THD (non‑linear load) | ≤1% @100% (linear load); ≤4% @100% (non‑linear load) | ≤1% @100% (linear load); ≤4% @100% (non‑linear load) |
| Время перевода От сети на аккумулятор Переключение с инвертора на байпас | 4ms (standard condition) Pure sine wave | 4ms (standard condition) Pure sine wave | 4ms (standard condition) Pure sine wave | 0 мс Н/Д | 0 мс Н/Д |
| Характеристика сигнала (режим работы от аккумулятора) | Pure sine wave | Pure sine wave | Pure sine wave | Н/Д | Н/Д |
| Эффективность | |||||
| Режим кондиционирования | 88% | 89% | 90% | >95% (Max) | >95% (Max) |
| Режим работы от аккумулятора | 83% | 85% | 88% | >93% (Max) | >93% (Max) |
| Battery — Standard Model | |||||
| Модель аккумулятора | 12V/7AH | 12V/7AH | 12V/7AH | 12V/7AH | 12V/9AH |
| Количество батарей | 2 | 4 | 6 | 16 | 16 |
| Зарядный ток | 1A | 1A | 1A | 1A±10% (Default) | 1A±10% (Default) |
| Battery — Long‑run Model | |||||
| Модель аккумулятора | Subject to supplier | Subject to supplier | Subject to supplier | Subject to application | Subject to application |
| Количество батарей | 3 | 6 | 8 | 16‑20 | 16‑20 |
| Зарядный ток | 1А/2А/4А/6А | 1А/2А/4А/6А | 1А/2А/4А/6А | 2A±10% (Default); Optional:1A/2A/4A/6A/8A | 2A±10% (Default); Optional:1A/2A/4A/6A/8A |
| Physical Performance — Standard Model | |||||
| Dimension: D×W×H (mm) | 310×438×88 | 410×438×88 | 630×438×88 | UPS:509×438×88 [2U] Battery Pack:688×438×88 [2U] | UPS:509×438×88 [2U] Battery Pack:688×438×88 [2U] |
| Вес нетто (кг) | 12 | 19 | 29.3 | UPS:11; Battery Pack:48 | UPS:12.1; Battery Pack:53 |
| Physical Performance — Long‑run Model | |||||
| Dimension: D×W×H (mm) | 310×438×88 | 410×438×88 | 410×438×88 | 530×438×88 [2U] | 580×438×133 [3U] |
| Вес нетто (кг) | 9 | 12 | 14.2 | 11 | 12.1 |
| Условия эксплуатации | |||||
| Рабочая влажность | 20‑90% RH @0‑40℃ (Non‑condensing) | 20‑90% RH @0‑40℃ (Non‑condensing) | 20‑90% RH @0‑40℃ (Non‑condensing) | <95% & non‑condensing | <95% & non‑condensing |
| Шум | <50dB@1 Meter | <50dB@1 Meter | <50dB@1 Meter | <55dB@1 Meter | <58dB@1 Meter |
| Рабочая температура | Н/Д | Н/Д | Н/Д | 0‑40℃ (Battery life shortens above 25℃) | 0‑40℃ (Battery life shortens above 25℃) |
| Max Operating Altitude | Н/Д | Н/Д | Н/Д | <1000m** | <1000m** |
| Контроль и управление | |||||
| Intelligent RS‑232/USB | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | Support Windows®2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC |
| Дополнительная поддержка SNMP | Power management via SNMP manager and web browser | Power management via SNMP manager and web browser | Power management via SNMP manager and web browser | Power management via SNMP manager and web browser | Power management via SNMP manager and web browser |
Footer Note:
Технические характеристики могут быть изменены без предварительного уведомления.
Типичные области применения
Серверные шкафы, сетевые помещения, телекоммуникационные системы, оборудование для обеспечения безопасности, финансовый сектор, сфера образования и распределенные ИТ-нагрузки.
Подбор и планирование проекта
Перед оформлением заказа необходимо свериться с выбранной моделью и проектной документацией, чтобы уточнить точные номинальные параметры мощности, фазу входа/выхода, напряжение, частоту, коэффициент мощности, напряжение аккумулятора, время автономной работы, режим байпаса, возможности связи, габаритные размеры, предельные условия эксплуатации и способ монтажа.
Часто задаваемые вопросы
Можно ли настроить этот продукт под конкретный проект?
Да. Электрическую схему, время автономной работы от аккумулятора, средства связи, обходной контур, расположение шкафов и дополнительное оборудование для проекта можно согласовать с учетом требований объекта.
Все ли технические рейтинги одинаковы для всей серии?
Нет. Технические характеристики и функции зависят от модели и конфигурации. В качестве окончательного справочного материала используйте техническое описание, относящееся к конкретному проекту.
Может ли компания DAXIN ENERGY оказать поддержку в выборе системы?
Да. Предоставьте перечень нагрузок, фазы и напряжение, требуемое время автономной работы, целевые показатели резервирования, требования к связи и условия установки.
Запросить конфигурацию проекта
Отправьте данные о нагрузке, однолинейную схему, требуемое время автономной работы и условия эксплуатации, чтобы получить индивидуальное предложение по ИБП или аккумуляторной батарее.