80kVA Low-Frequency Online UPS | DAXIN 3H3

The DAXIN 3H3 80kVA is an 80kVA/64kW low-frequency 3/3 phase online UPS designed for high-capacity critical power applications requiring three-phase input and three-phase output. Featuring online power protection, 0ms mains-to-battery transfer and project-configurable battery, bypass and monitoring options, it is suitable for data centers, industrial facilities, power infrastructure, transportation, healthcare and other critical three-phase loads.

Get a Quote & Technical Support

Send your application, quantity and technical requirements. Our engineering team will respond with a suitable configuration.

Description

What Is the DAXIN 3H3 80kVA 3/3 Phase Online UPS?

The DAXIN 3H3 80kVA is an 80kVA/64kW low-frequency online UPS designed for critical applications requiring three-phase input and three-phase output power protection.

Its 3/3 phase architecture is intended for facilities where both the incoming electrical supply and protected critical loads operate on three-phase power.

The reference configuration supports 380/400/415VAC three-phase input and output, 0ms mains-to-battery transfer and greater than 90% efficiency.

Battery configuration, bypass, communications, redundancy requirements and other project parameters should be confirmed according to the connected load, required backup time and approved DAXIN technical proposal.

Key Benefits

  • 80kVA / 64kW Capacity: Designed for high-capacity critical three-phase loads in industrial and infrastructure applications.
  • 3/3 Phase Architecture: Three-phase input and three-phase output support large three-phase electrical systems.
  • Low-Frequency UPS Design: Intended for demanding industrial and infrastructure critical-power applications.
  • Online Power Protection: Provides conditioned power for sensitive and mission-critical loads.
  • 0ms Mains-to-Battery Transfer: Maintains output during utility-to-battery transition according to the reference specification.
  • Configurable Battery System: Battery configuration and runtime can be engineered according to load and backup-time requirements.
  • Monitoring and Protection: Display, alarm, protection and communication functions support system operation and maintenance.
  • Project-Based Configuration: Parallel, redundancy, bypass and communication capabilities must be confirmed for the selected configuration.

What Does 3/3 Phase Mean in a UPS?

A 3/3 phase UPS uses three-phase AC power at the input and supplies three-phase AC power at the output.

This configuration is commonly used for medium- and high-capacity critical loads in data centers, industrial facilities, telecom infrastructure, healthcare systems and other facilities operating three-phase electrical equipment.

The DAXIN 3H3 80kVA uses this three-phase input and three-phase output architecture for critical-power applications requiring 80kVA-class UPS capacity.

What Loads Can an 80kVA UPS Support?

The DAXIN 3H3 80kVA reference model is rated at 80kVA / 64kW. The actual equipment that can be supported depends on the combined active power, power factor, startup or peak demand and required operating margin of the connected loads.

UPS sizing should be based on measured or calculated load data rather than equipment quantity alone. Future expansion and required battery runtime should also be considered during system design.

Key Specifications
DAXIN 3H3 80kVA Key Specifications

Parameter3H3-80kVA
Rated Capacity80kVA / 64kW
PhaseThree-Phase Input / Three-Phase Output
Input Voltage3×380 / 400 / 415VAC
Input Voltage Range285–475VAC
Input Frequency46–54Hz @ 50Hz; 56–64Hz @ 60Hz
Output Voltage380 / 400 / 415VAC
Battery-Mode Frequency50/60Hz ±0.1Hz
Output THD<3% Linear / <5% Non-linear
Mains-to-Battery Transfer0ms
Efficiency>90%
Battery TypeSealed Lead-Acid, Maintenance-Free
Battery Quantity29 / 30 / 31 / 32 pcs, 12V Series
Dimensions975 × 554 × 1286 mm*
Net Weight400 kg
Operating Temperature0–55°C
Relative Humidity<95%, Non-Condensing
Operating Altitude<1000m
CommunicationRS-232 / USB
SNMPOptional

Product Views and Technical Reference

DAXIN 3H3-60kVA 3/3 Phase Online UPS Technical Specifications
Technical specifications for the DAXIN 3H3-60kVA 3/3 phase online UPS.
Control Panel and Front Detail for DAXIN 3H3 80kVA Low-Frequency 3/3 Phase UPS.

Typical Applications

  • Data centers and server facilities
  • Industrial plants and manufacturing systems
  • Power and utility infrastructure
  • Telecom core facilities
  • Hospitals and critical healthcare systems
  • Transportation and tunnel infrastructure
  • Commercial and public infrastructure
  • Other high-capacity three-phase critical loads

How to Select an 80kVA Three-Phase UPS

Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, startup or peak demand, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.

For a 3/3 phase UPS, confirm that both the site electrical supply and protected critical loads require three-phase power.

Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communication interfaces and installation conditions for project configuration.

Selection and Project Planning

Confirm the exact power rating, input/output phase, voltage, frequency, power factor, battery voltage, runtime, bypass, communications, dimensions, environmental limits and installation method against the selected model and project drawings before ordering.

Frequently Asked Questions

Can this product be configured for a specific project?

Yes. Electrical configuration, battery runtime, communications, bypass, cabinet arrangement and project accessories can be reviewed against the site requirements.

Are all technical ratings shared across the full series?

No. Ratings and functions vary by model and configuration. Use the project-specific technical sheet as the final reference.

Can DAXIN ENERGY support system selection?

Yes. Provide the load list, phase and voltage, required runtime, redundancy target, communication requirements and installation environment.

Request a Project Configuration

Send the load data, single-line diagram, required backup time and site conditions to receive a tailored UPS or battery proposal.

What is the rated capacity of the DAXIN 3H3 80kVA?

The reference model is rated at 80kVA / 64kW.

What does 3/3 phase mean?

It means the UPS uses three-phase input and provides three-phase output.

What is the mains-to-battery transfer time?

The reference specification lists 0ms mains-to-battery transfer.

What output voltage does the UPS support?

The reference configuration supports 380/400/415VAC three-phase output.

How should an 80kVA UPS be sized?

UPS sizing should consider actual load in kW and kVA, power factor, peak demand, future expansion, required operating margin and backup-time requirements.

Can the 80kVA UPS support parallel redundancy?

Parallel and redundancy capabilities depend on the selected configuration and must be confirmed against the approved technical specification before system design.