The DAXIN 11-H Series is a 1-10kVA high-frequency single-phase online UPS family designed for continuous power protection of telecom, IT, healthcare, industrial control and other critical equipment. Featuring true online double-conversion, 0ms mains-to-battery transfer, up to 0.9 output power factor, ECO mode, generator compatibility and configurable long-run battery options, the series is available in 1kVA, 2kVA, 3kVA, 6kVA and 10kVA capacities. Optional SNMP monitoring and isolation transformer configurations are available according to project requirements.

Get a Quote & Technical Support

Send your application, quantity and technical requirements. Our engineering team will respond with a suitable configuration.

Description

Is This UPS Right for Your Project?

The DAXIN 11-H Series covers 1-10kVA online UPS requirements for customers who need continuous double-conversion protection, external battery options and flexible communications.

The series allows a project to select capacity and runtime around the actual load instead of oversizing every installation to one fixed model.

Typical Applications

  • Server and network rooms
  • Telecom and industrial control systems
  • Medical and laboratory equipment
  • Security and transportation infrastructure

What to Confirm Before Ordering

  • Load capacity and future expansion
  • Standard or long-runtime battery configuration
  • Lead-acid or compatible lithium battery design
  • RS-232, USB, SNMP and external battery requirements

Frequently Asked Questions

How should I choose the UPS capacity?

Start with the measured continuous load, startup or peak demand and expected expansion. DAXIN ENERGY can review the load list and recommend a practical operating margin.

How is battery runtime determined?

Runtime depends on load, battery voltage, battery capacity, battery age, temperature and inverter efficiency. Share the required backup duration and normal load for a project calculation.

Can this UPS work with a generator or remote monitoring system?

Generator and monitoring compatibility depends on the selected model and configuration. Confirm generator capacity, frequency stability and the required RS-232, RS-485, USB, Modbus or SNMP interface before ordering.

Request a Project Configuration

Send DAXIN ENERGY the load list, site voltage, required runtime, installation environment, communications and redundancy requirements. The final configuration is subject to the approved technical proposal.

DAXIN High-Frequency UPS Product Video

Watch the product demonstration to review the UPS format, operating interface and application positioning. Final electrical configuration is subject to the approved technical proposal.

High-Frequency Single-Phase Online UPS Series (1-10kVA) With ECO Mode And Generator Compatibility

High-Frequency Single-Phase Online UPS Series (1-10kVA) With ECO Mode And Generator Compatibility – DAXIN ENERGY.

What Is the DAXIN 11-H Series 1-10kVA Online UPS?

The DAXIN 11-H Series is a high-frequency single-phase online UPS family available in 1kVA, 2kVA, 3kVA, 6kVA and 10kVA capacities. It is designed to provide continuous power protection for telecom, IT, healthcare, industrial control, financial and other critical electronic equipment.

Using true online double-conversion technology, the UPS continuously supplies connected loads through the inverter, providing 0ms mains-to-battery transfer during utility power interruptions.

The series supports wide input-voltage operation, input power factor correction, pure sine-wave output, ECO mode, generator compatibility and intelligent battery charging. Communication options include RS-232 and USB, with optional SNMP network management for remote UPS monitoring.

Standard and long-run configurations are available according to model and backup-time requirements. Optional features such as an isolation transformer and maintenance bypass can be reviewed according to the selected configuration and project requirements.

11-H Series Models

ModelRated CapacityTopologyPhase
11-H1kVA1000VA / 900WOnline Double-ConversionSingle Phase
11-H2kVA2000VA / 1800WOnline Double-ConversionSingle Phase
11-H3kVA3000VA / 2700WOnline Double-ConversionSingle Phase
11-H6kVA6000VA / 5400WOnline Double-ConversionSingle Phase
11-H10kVA10000VA / 9000WOnline Double-ConversionSingle Phase

Key Features

  • True Online Double-Conversion: Provides continuous conditioned power for critical connected loads.
  • 1-10kVA Capacity Range: Available in 1kVA, 2kVA, 3kVA, 6kVA and 10kVA models.
  • 0ms Mains-to-Battery Transfer: Online topology maintains inverter-supplied output during utility interruptions.
  • Single-Phase Configuration: Designed for single-phase input and output applications.
  • High Input Power Factor: Input power factor up to ≥0.99 under specified operating conditions.
  • 0.9 Output Power Factor: Provides up to 900W active power per 1kVA of rated capacity across the listed models.
  • Pure Sine-Wave Output: Designed for sensitive electronic and critical equipment.
  • Wide Input Operating Range: Supports operation under varying utility conditions according to model and load.
  • Generator Compatibility: Suitable for integration with compatible standby generator systems.
  • ECO Mode: Provides an alternative high-efficiency operating mode where appropriate.
  • Flexible Battery Configuration: Standard and long-run battery options are available according to model and runtime requirements.
  • Remote UPS Monitoring: RS-232 and USB communication with optional SNMP network management.
  • Optional Isolation Transformer: Available for project configurations requiring additional electrical isolation.

Typical Applications

  • Telecom base stations, communication and network equipment
  • Servers, workstations and IT infrastructure
  • Healthcare and laboratory equipment
  • Industrial automation and control systems
  • Banking and financial systems
  • Government and public-sector IT infrastructure
  • Education and research facilities
  • Transportation and traffic-control systems
  • Security and surveillance equipment
  • Utility monitoring and power-control systems

Why Use an Online Double-Conversion UPS?

An online double-conversion UPS continuously powers connected loads through the inverter rather than waiting for a utility failure before switching to battery operation.

This architecture provides 0ms mains-to-battery transfer and helps isolate critical equipment from certain utility-power disturbances. It is commonly selected for applications where power continuity and output quality are important, including telecom, IT, healthcare, industrial control and other critical infrastructure.

How to Select the Right 11-H Series UPS

Selecting the correct UPS capacity requires more than matching the nominal kVA rating. Consider the total active load in watts, equipment power factor, startup or surge requirements, required backup time, input-voltage conditions, communication requirements and future load expansion.

For long-runtime applications, battery capacity should be selected according to the actual connected load and required backup duration.

Provide DAXIN ENERGY with your equipment list, total load, input and output voltage, required backup time, communication requirements and installation conditions to determine the appropriate UPS and battery configuration.


11-H Series (Long-run Model)

1. Power Range: 1kVA – 10kVA
Working Mode: Single-phase input/output, online double-conversion.
Applications: Widely used in government, finance, telecommunications, education, transportation, meteorology, broadcasting, taxation, healthcare, energy, power, and various other industries.

Product Features:

  • True Online Double-Conversion: Ensures continuous, clean power.

  • Microprocessor Control: Optimized for maximum reliability.

  • Input Power Factor Correction: Improves energy efficiency and reduces harmonics.

  • High Output Power Factor: Output PF up to 0.9.

  • Wide Input Voltage Range: Handles unstable grids (90V – 300V).

  • Efficient Frequency Converter Mode: Adaptable for specialized equipment.

  • Generator Compatible: Works seamlessly with backup generator systems.

  • Enhanced Monitoring: Optional SNMP card for perfect monitoring via network, or integrated with USB/RS232.

  • User-friendly LCD Display: Comprehensive monitoring and easy control of UPS status.

  • ECO Mode: Provides high-efficiency energy-saving operation.

  • Emergency Power Off (EPO): Instant shutdown for safety.

  • Advanced DSP Technology: Integrated into the series; built-in maintenance bypass switch (optional).

  • Smart Battery Charger: Designed to extend battery life and optimize performance.

  • Isolation Transformer: Optional built-in isolation for enhanced protection.

2. Technical Specifications :

Category (类别)Parameter (参数项目)11-H1kVA11-H2kVA11-H3kVA11-H6kVA11-H10kVA
CapacityRated Capacity1000VA/900W2000VA/1800W3000VA/2700W6000VA/5400W10000VA/9000W
InputVoltage Range110-300VAC (Based on load percentage)110-300VAC110-300VAC110-300VAC110-300VAC
Frequency Range40Hz – 70Hz40Hz – 70Hz40Hz – 70Hz40Hz – 70Hz40Hz – 70Hz
Power Factor≥ 0.99 @ Nominal Voltage (100% load)≥ 0.99≥ 0.99≥ 0.99≥ 0.99
OutputOutput Voltage208/220/230/240VAC208/220/230/240VAC208/220/230/240VAC208/220/230/240VAC208/220/230/240VAC
Voltage Regulation± 1%± 1%± 1%± 1%± 1%
Frequency (Synchronized)47-53Hz or 57-63Hz47-53Hz or 57-63Hz47-53Hz or 57-63Hz46-54Hz or 56-64Hz46-54Hz or 56-64Hz
Frequency (Battery Mode)50/60Hz ± 0.1Hz50/60Hz ± 0.1Hz50/60Hz ± 0.1Hz50/60Hz ± 0.1Hz50/60Hz ± 0.1Hz
Crest Factor3:13:13:13:13:1
Harmonic Distortion (THD)≤ 3% (Linear Load); ≤ 6% (Non-linear Load)≤ 3% / ≤ 6%≤ 3% / ≤ 6%≤ 3% / ≤ 9%≤ 3% / ≤ 9%
Transfer Time0 ms (Inverter to Bypass: 4ms typical)0 ms0 ms0 ms0 ms
WaveformPure Sine WavePure Sine WavePure Sine WavePure Sine WavePure Sine Wave
EfficiencyMains Mode88%89%90%92%93%
Battery Mode83%87%88%90%91%
BatteryStandard Model (S)12V/7Ah (or 9Ah)12V/7Ah12V/7Ah12V/7Ah12V/7Ah
Quantity2461216
Charging Current1.0 A1.0 A1.0 A1.0A ± 10% (Default)1.0A ± 10% (Default)
Long-run Model (L)External (Depends on capacity)ExternalExternalExternalExternal
Quantity3681616
Charging Current1A / 2A / 4A / 6A (Adjustable)1A-6A1A-6A1A-6A1A-6A
PhysicalStandard (S) Dim (DxWxH)282 x 145 x 220 mm397 x 145 x 220 mm421 x 190 x 318 mm369 x 190 x 688 mm442 x 190 x 688 mm
Standard (S) Net Weight9.8 kg17 kg26.2 kg51 kg55 kg
Long-run (L) Dim (DxWxH)282 x 145 x 220 mm397 x 145 x 220 mm397 x 145 x 220 mm369 x 190 x 318 mm442 x 190 x 318 mm
Long-run (L) Net Weight4.4 kg6.8 kg7.4 kg12 kg15 kg
EnvironmentHumidity20-90% RH @ 0-40°C (Non-condensing)< 95% RH (Non-condensing)
Noise Level< 50dB @ 1 meter< 50dB @ 1m< 50dB @ 1m< 55dB @ 1m< 58dB @ 1m
ManagementInterfaceSupports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, and MAC
Optional SNMPPower management supports SNMP and Web browser monitoring

Technical Notes

  • For 1-3kVA models, output capacity is derated to 80% in CVCF mode or when the output voltage is configured to 208VAC.
  • For 6kVA and 10kVA models, output capacity is derated to 60% in CVCF mode and to 90% when the output voltage is configured to 208VAC.
  • Standard models do not support redundant parallel operation.
  • Available output-voltage settings and battery configurations depend on the selected model and version.
  • Specifications and optional functions are subject to the approved technical data sheet and project configuration.

    FAQ:

    What capacities are available in the DAXIN 11-H Series?

    The DAXIN 11-H Series is available in 1kVA, 2kVA, 3kVA, 6kVA and 10kVA capacities, with rated active power from 900W to 9000W.

    Is the 11-H Series a true online UPS?

    Yes. The 11-H Series uses online double-conversion topology to provide continuous inverter-supplied power to connected critical loads.

    What is the transfer time during a power failure?

    The specified mains-to-battery transfer time is 0ms because the connected load is continuously supplied through the online inverter architecture.

    Can the 11-H Series work with a generator?

    Yes. The series supports operation with compatible generator systems. Generator capacity, voltage and frequency characteristics should be considered during system design.

    Can I use external batteries for longer backup time?

    Long-run configurations support external battery systems. Battery capacity should be selected according to UPS model, connected load, DC bus requirements and required backup time.

    Does the UPS support remote monitoring?

    Yes. RS-232 and USB communication are supported, with optional SNMP network management for remote monitoring according to the selected configuration.

Industrial Grade Online UPS (1-10kVA) for Telecom, Medical & Government - 11-H Series technical detail 1 by DAXIN ENERGY


Reviews

There are no reviews yet.

Be the first to review “1-10kVA High-Frequency Online UPS | DAXIN 11-H Series”

Your email address will not be published. Required fields are marked *