11-H2kVA (1-10kVA) Online Double-Conversion UPS – Long-run Model

“The 11-H2kVA Series is a high-performance, 1-10kVA long-run online UPS featuring true double-conversion technology and DSP control. With a 0.9 output power factor, wide input voltage range (90V-300V), and smart battery management, it’s the ideal power protection solution for telecommunications, healthcare, and industrial applications. Optional SNMP and isolation transformer available.”

Get a Quote & Technical Support

Send your application, quantity and technical requirements. Our engineering team will respond with a suitable configuration.

Description

1-H Series (Long-run Model)

1. Power Range: 1kVA – 10kVA
Working Mode: Single-phase input/output, online double-conversion.
Applications: Widely used in government, finance, telecommunications, education, transportation, meteorology, broadcasting, taxation, healthcare, energy, power, and various other industries.

Product Features:

  • True Online Double-Conversion: Ensures continuous, clean power.

  • Microprocessor Control: Optimized for maximum reliability.

  • Input Power Factor Correction: Improves energy efficiency and reduces harmonics.

  • High Output Power Factor: Output PF up to 0.9.

  • Wide Input Voltage Range: Handles unstable grids (90V – 300V).

  • Efficient Frequency Converter Mode: Adaptable for specialized equipment.

  • Generator Compatible: Works seamlessly with backup generator systems.

  • Enhanced Monitoring: Optional SNMP card for perfect monitoring via network, or integrated with USB/RS232.

  • User-friendly LCD Display: Comprehensive monitoring and easy control of UPS status.

  • ECO Mode: Provides high-efficiency energy-saving operation.

  • Emergency Power Off (EPO): Instant shutdown for safety.

  • Advanced DSP Technology: Integrated into the series; built-in maintenance bypass switch (optional).

  • Smart Battery Charger: Designed to extend battery life and optimize performance.

  • Isolation Transformer: Optional built-in isolation for enhanced protection.

2. Technical Notes:

Category Parameter 11-H1kVA11-H2kVA11-H3kVA11-H6kVA11-H10kVA
CapacityRated Capacity1000VA/900W2000VA/1800W3000VA/2700W6000VA/5400W10000VA/9000W
InputVoltage Range110-300VAC (Based on load percentage)110-300VAC110-300VAC110-300VAC110-300VAC
Frequency Range40Hz – 70Hz40Hz – 70Hz40Hz – 70Hz40Hz – 70Hz40Hz – 70Hz
Power Factor≥ 0.99 @ Nominal Voltage (100% load)≥ 0.99≥ 0.99≥ 0.99≥ 0.99
OutputOutput Voltage208/220/230/240VAC208/220/230/240VAC208/220/230/240VAC208/220/230/240VAC208/220/230/240VAC
Voltage Regulation± 1%± 1%± 1%± 1%± 1%
Frequency (Synchronized)47-53Hz or 57-63Hz47-53Hz or 57-63Hz47-53Hz or 57-63Hz46-54Hz or 56-64Hz46-54Hz or 56-64Hz
Frequency (Battery Mode)50/60Hz ± 0.1Hz50/60Hz ± 0.1Hz50/60Hz ± 0.1Hz50/60Hz ± 0.1Hz50/60Hz ± 0.1Hz
Crest Factor3:13:13:13:13:1
Harmonic Distortion (THD)≤ 3% (Linear Load); ≤ 6% (Non-linear Load)≤ 3% / ≤ 6%≤ 3% / ≤ 6%≤ 3% / ≤ 9%≤ 3% / ≤ 9%
Transfer Time0 ms (Inverter to Bypass: 4ms typical)0 ms0 ms0 ms0 ms
WaveformPure Sine WavePure Sine WavePure Sine WavePure Sine WavePure Sine Wave
EfficiencyMains Mode88%89%90%92%93%
Battery Mode83%87%88%90%91%
BatteryStandard Model (S)12V/7Ah (or 9Ah)12V/7Ah12V/7Ah12V/7Ah12V/7Ah
Quantity2461216
Charging Current1.0 A1.0 A1.0 A1.0A ± 10% (Default)1.0A ± 10% (Default)
Long-run Model (L)External (Depends on capacity)ExternalExternalExternalExternal
Quantity3681616
Charging Current1A / 2A / 4A / 6A (Adjustable)1A-6A1A-6A1A-6A1A-6A
PhysicalStandard (S) Dim (DxWxH)282 x 145 x 220 mm397 x 145 x 220 mm421 x 190 x 318 mm369 x 190 x 688 mm442 x 190 x 688 mm
Standard (S) Net Weight9.8 kg17 kg26.2 kg51 kg55 kg
Long-run (L) Dim (DxWxH)282 x 145 x 220 mm397 x 145 x 220 mm397 x 145 x 220 mm369 x 190 x 318 mm442 x 190 x 318 mm
Long-run (L) Net Weight4.4 kg6.8 kg7.4 kg12 kg15 kg
EnvironmentHumidity20-90% RH @ 0-40°C (Non-condensing)< 95% RH (Non-condensing)
Noise Level< 50dB @ 1 meter< 50dB @ 1m< 50dB @ 1m< 55dB @ 1m< 58dB @ 1m
ManagementInterfaceSupports Windows 2000/2003/XP/Vista/2008, Windows 7/8, Linux, and MAC
Optional SNMPPower management supports SNMP and Web browser monitoring

  • Output power derating: Output power is derated to 80% in frequency conversion mode; when the output voltage is set to 208VAC, the power is also derated (1-3kVA to 80%, 6-10kVA to 90%).

  • Specifications Change: Specifications are subject to change without prior notice.

    • Derating (1-3kVA): Output power derates to 80% in CVCF mode or at 208VAC output.

    • Derating (6/10kVA): Output power derates to 60% in CVCF mode and to 90% at 208VAC output.

    • Parallel Redundancy: Not supported for the above standard models.

    • Voltage Support: 200/208/220/230/240VAC is available for long-run models only.

11-H2kVA (1-10kVA) Online Double-Conversion UPS - Long-run Model technical detail 1 by DAXIN ENERGY