80 kVA Düşük Frekanslı Çevrimiçi UPS | DAXIN 3H3

The DAXIN 3H3 80kVA is an 80kVA/64kW low-frequency 3/3 phase online UPS designed for high-capacity critical power applications requiring three-phase input and three-phase output. Featuring online power protection, 0ms mains-to-battery transfer and project-configurable battery, bypass and monitoring options, it is suitable for data centers, industrial facilities, power infrastructure, transportation, healthcare and other critical three-phase loads.

Fiyat Teklifi Alın ve Teknik Destek Alın

Başvurunuzu, talep ettiğiniz miktarı ve teknik gereksinimlerinizi bize iletin. Mühendislik ekibimiz size uygun bir konfigürasyon önerisiyle yanıt verecektir.

Açıklama

What Is the DAXIN 3H3 80kVA 3/3 Phase Online UPS?

The DAXIN 3H3 80kVA is an 80kVA/64kW low-frequency online UPS designed for critical applications requiring three-phase input and three-phase output power protection.

3/3 fazlı mimarisi, hem gelen elektrik beslemesi hem de korunan kritik yüklerin üç fazlı güçle çalıştığı tesisler için tasarlanmıştır.

Referans konfigürasyon, 380/400/415 VAC üç fazlı giriş ve çıkışı, 0 ms şebeke-akü geçiş süresini ve 90%’den yüksek verimliliği desteklemektedir.

Pil konfigürasyonu, baypas, iletişim, yedeklilik gereksinimleri ve diğer proje parametreleri, bağlı yük, gerekli yedekleme süresi ve onaylanmış DAXIN teknik teklifine göre teyit edilmelidir.

Başlıca Avantajlar

  • 80kVA / 64kW Capacity: Designed for high-capacity critical three-phase loads in industrial and infrastructure applications.
  • 3/3 Fazlı Mimari: Three-phase input and three-phase output support large three-phase electrical systems.
  • Düşük Frekanslı UPS Tasarımı: Intended for demanding industrial and infrastructure critical-power applications.
  • Çevrimiçi Güç Koruması: Hassas ve görev açısından kritik yükler için stabilize edilmiş güç sağlar.
  • 0 ms Şebeke-Pil Geçişi: Referans teknik şartnamesine göre, şebeke-pil geçişi sırasında güç çıkışını korur.
  • Yapılandırılabilir Pil Sistemi: Battery configuration and runtime can be engineered according to load and backup-time requirements.
  • İzleme ve Koruma: Ekran, alarm, koruma ve iletişim işlevleri, sistemin çalıştırılması ve bakımını destekler.
  • Proje Tabanlı Yapılandırma: Seçilen yapılandırma için paralel, yedeklilik, baypas ve iletişim özelliklerinin doğrulanması gerekir.

Bir UPS’te “3/3 faz” ne anlama gelir?

3/3 fazlı bir UPS, girişte üç fazlı alternatif akım kullanır ve çıkışta üç fazlı alternatif akım sağlar.

This configuration is commonly used for medium- and high-capacity critical loads in data centers, industrial facilities, telecom infrastructure, healthcare systems and other facilities operating three-phase electrical equipment.

The DAXIN 3H3 80kVA uses this three-phase input and three-phase output architecture for critical-power applications requiring 80kVA-class UPS capacity.

What Loads Can an 80kVA UPS Support?

The DAXIN 3H3 80kVA reference model is rated at 80kVA / 64kW. The actual equipment that can be supported depends on the combined active power, power factor, startup or peak demand and required operating margin of the connected loads.

UPS sizing should be based on measured or calculated load data rather than equipment quantity alone. Future expansion and required battery runtime should also be considered during system design.

Key Specifications
DAXIN 3H3 80kVA Key Specifications

Parametre3H3-80kVA
Nominal Kapasite80kVA / 64kW
AşamaÜç Fazlı Giriş / Üç Fazlı Çıkış
Giriş Gerilimi3×380 / 400 / 415VAC
Input Voltage Range285–475VAC
Giriş Frekansı46–54Hz @ 50Hz; 56–64Hz @ 60Hz
Çıkış Gerilimi380 / 400 / 415VAC
Battery-Mode Frequency50/60Hz ±0.1Hz
Çıkış THD'si<3% Linear / <5% Non-linear
Mains-to-Battery Transfer0 ms
Verimlilik>90%
Pil TürüSealed Lead-Acid, Maintenance-Free
Pil Adedi29 / 30 / 31 / 32 pcs, 12V Series
Boyutlar975 × 554 × 1286 mm*
Net Ağırlık400 kg
Çalışma Sıcaklığı0–55°C
Bağıl Nem<95%, Non-Condensing
Çalışma İrtifası<1000m
İletişimRS-232 / USB
SNMPOptional

Ürün Görünümleri ve Teknik Referans

DAXIN 3H3-60kVA 3/3 Fazlı Çevrimiçi UPS Teknik Özellikleri
Technical specifications for the DAXIN 3H3-60kVA 3/3 phase online UPS.
Control Panel and Front Detail for DAXIN 3H3 80kVA Low-Frequency 3/3 Phase UPS.

Tipik Uygulamalar

  • Data centers and server facilities
  • Industrial plants and manufacturing systems
  • Power and utility infrastructure
  • Telekom çekirdek tesisleri
  • Hospitals and critical healthcare systems
  • Transportation and tunnel infrastructure
  • Ticari ve kamu altyapısı
  • Other high-capacity three-phase critical loads

How to Select an 80kVA Three-Phase UPS

UPS’i, kW ve kVA cinsinden gerçek bağlı yük, giriş ve çıkış gerilimi, güç faktörü, başlangıç veya tepe yük talebi, gerekli yedekleme süresi, akü konfigürasyonu, baypas gereksinimleri, yedeklilik mimarisi, iletişim arayüzleri ve kurulum ortamına göre seçin.

3/3 fazlı bir UPS için, hem tesisin elektrik beslemesinin hem de korunacak kritik yüklerin üç fazlı güç gerektirdiğinden emin olun.

Proje yapılandırması için DAXIN ENERGY’ye yük listesini, tek hat şemasını, tesis gerilimini, gerekli çalışma süresini, yedeklilik gereksinimlerini, iletişim arayüzlerini ve kurulum koşullarını sağlayın.

Seçim ve Proje Planlaması

Sipariş vermeden önce, seçilen modele ve proje çizimlerine göre tam güç değerini, giriş/çıkış fazını, gerilimi, frekansı, güç faktörünü, akü gerilimini, çalışma süresini, baypas özelliğini, iletişim özelliklerini, boyutları, çevresel sınırları ve kurulum yöntemini teyit ediniz.

Sık Sorulan Sorular

Bu ürün belirli bir projeye göre özelleştirilebilir mi?

Evet. Elektrik konfigürasyonu, pil çalışma süresi, iletişim, baypas, kabin düzeni ve proje aksesuarları, tesisin gereksinimlerine göre gözden geçirilebilir.

Tüm teknik derecelendirmeler serinin tamamında ortak mıdır?

Hayır. Teknik özellikler ve işlevler modele ve yapılandırmaya göre değişiklik gösterir. Nihai referans olarak projeye özgü teknik veri sayfasını kullanın.

DAXIN ENERGY, sistem seçiminde destek sağlayabilir mi?

Evet. Yük listesini, faz ve gerilimi, gerekli çalışma süresini, yedeklilik hedefini, iletişim gereksinimlerini ve kurulum ortamını belirtin.

Proje Yapılandırması Talep Et

Özel olarak hazırlanmış bir UPS veya akü teklifi almak için yük verilerini, tek hat şemasını, gerekli yedekleme süresini ve saha koşullarını bize gönderin.

What is the rated capacity of the DAXIN 3H3 80kVA?

The reference model is rated at 80kVA / 64kW.

3/3 faz ne anlama gelir?

Bu, UPS’in üç fazlı giriş kullandığı ve üç fazlı çıkış sağladığı anlamına gelir.

Şebeke akımından aküye geçiş süresi ne kadardır?

Referans teknik özelliklerinde, şebekeden aküye geçiş süresinin 0 ms olduğu belirtilmiştir.

UPS hangi çıkış gerilimini destekliyor?

Referans konfigürasyon, 380/400/415 VAC üç fazlı çıkışı desteklemektedir.

How should an 80kVA UPS be sized?

UPS sizing should consider actual load in kW and kVA, power factor, peak demand, future expansion, required operating margin and backup-time requirements.

Can the 80kVA UPS support parallel redundancy?

Parallel and redundancy capabilities depend on the selected configuration and must be confirmed against the approved technical specification before system design.

Yorumlar

Henüz herhangi bir yorum yok.

“80kVA Low-Frequency Online UPS | DAXIN 3H3” için ilk yorum yazan siz olun”

E-posta adresiniz yayınlanmayacak. Gerekli alanlar * ile işaretlenmişlerdir