Beschreibung
What Is the DAXIN 3H3 80kVA 3/3 Phase Online UPS?
The DAXIN 3H3 80kVA is an 80kVA/64kW low-frequency online UPS designed for critical applications requiring three-phase input and three-phase output power protection.
Its 3/3 phase architecture is intended for facilities where both the incoming electrical supply and protected critical loads operate on three-phase power.
The reference configuration supports 380/400/415VAC three-phase input and output, 0ms mains-to-battery transfer and greater than 90% efficiency.
Battery configuration, bypass, communications, redundancy requirements and other project parameters should be confirmed according to the connected load, required backup time and approved DAXIN technical proposal.
Wichtigste Vorteile
- 80kVA / 64kW Capacity: Designed for high-capacity critical three-phase loads in industrial and infrastructure applications.
- 3/3 Phase Architecture: Three-phase input and three-phase output support large three-phase electrical systems.
- Low-Frequency UPS Design: Intended for demanding industrial and infrastructure critical-power applications.
- Online Power Protection: Provides conditioned power for sensitive and mission-critical loads.
- 0 ms Umschaltung von Netzstrom auf Batterie: Maintains output during utility-to-battery transition according to the reference specification.
- Configurable Battery System: Battery configuration and runtime can be engineered according to load and backup-time requirements.
- Monitoring and Protection: Display, alarm, protection and communication functions support system operation and maintenance.
- Project-Based Configuration: Parallel, redundancy, bypass and communication capabilities must be confirmed for the selected configuration.
What Does 3/3 Phase Mean in a UPS?
A 3/3 phase UPS uses three-phase AC power at the input and supplies three-phase AC power at the output.
This configuration is commonly used for medium- and high-capacity critical loads in data centers, industrial facilities, telecom infrastructure, healthcare systems and other facilities operating three-phase electrical equipment.
The DAXIN 3H3 80kVA uses this three-phase input and three-phase output architecture for critical-power applications requiring 80kVA-class UPS capacity.
What Loads Can an 80kVA UPS Support?
The DAXIN 3H3 80kVA reference model is rated at 80kVA / 64kW. The actual equipment that can be supported depends on the combined active power, power factor, startup or peak demand and required operating margin of the connected loads.
UPS sizing should be based on measured or calculated load data rather than equipment quantity alone. Future expansion and required battery runtime should also be considered during system design.
Key Specifications
DAXIN 3H3 80kVA Key Specifications
| Parameter | 3H3-80kVA |
|---|---|
| Nennkapazität | 80kVA / 64kW |
| Phase | Three-Phase Input / Three-Phase Output |
| Eingangsspannung | 3×380 / 400 / 415VAC |
| Eingangsspannungsbereich | 285–475VAC |
| Eingangsfrequenz | 46–54Hz @ 50Hz; 56–64Hz @ 60Hz |
| Ausgangsspannung | 380 / 400 / 415VAC |
| Battery-Mode Frequency | 50/60Hz ±0.1Hz |
| Ausgangs-THD | <3% Linear / <5% Non-linear |
| Mains-to-Battery Transfer | 0 ms |
| Effizienz | >90% |
| Batterietyp | Sealed Lead-Acid, Maintenance-Free |
| Anzahl der Batterien | 29 / 30 / 31 / 32 pcs, 12V Series |
| Abmessungen | 975 × 554 × 1286 mm* |
| Nettogewicht | 400 kg |
| Betriebstemperatur | 0–55°C |
| Relative Luftfeuchtigkeit | <95%, Non-Condensing |
| Betriebshöhe | <1000 m |
| Kommunikation | RS-232 / USB |
| SNMP | Optional |
Produktansichten und technische Informationen

Typische Anwendungsbereiche
- Data centers and server facilities
- Industrial plants and manufacturing systems
- Power and utility infrastructure
- Telecom core facilities
- Hospitals and critical healthcare systems
- Transportation and tunnel infrastructure
- Commercial and public infrastructure
- Other high-capacity three-phase critical loads
How to Select an 80kVA Three-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, startup or peak demand, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.
For a 3/3 phase UPS, confirm that both the site electrical supply and protected critical loads require three-phase power.
Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communication interfaces and installation conditions for project configuration.
Auswahl und Projektplanung
Bitte überprüfen Sie vor der Bestellung die genauen Angaben zu Nennleistung, Eingangs-/Ausgangsphase, Spannung, Frequenz, Leistungsfaktor, Batteriespannung, Laufzeit, Bypass, Kommunikationsschnittstellen, Abmessungen, Umgebungsbedingungen und Installationsart anhand des ausgewählten Modells und der Projektzeichnungen.
Häufig gestellte Fragen
Kann dieses Produkt für ein bestimmtes Projekt angepasst werden?
Ja. Die elektrische Konfiguration, die Batterielaufzeit, die Kommunikationsfunktionen, der Bypass, die Gehäuseanordnung und das Projektzubehör können anhand der Anforderungen vor Ort überprüft werden.
Gelten alle technischen Bewertungen für die gesamte Serie?
Nein. Die Nennleistungen und Funktionen variieren je nach Modell und Konfiguration. Als maßgebliche Grundlage dient das projektspezifische technische Datenblatt.
Kann DAXIN ENERGY bei der Systemauswahl helfen?
Ja. Bitte geben Sie die Lastliste, die Phase und die Spannung, die erforderliche Laufzeit, das Redundanzziel, die Kommunikationsanforderungen und die Installationsumgebung an.
Projektkonfiguration anfordern
Senden Sie uns die Lastdaten, das Einliniendiagramm, die erforderliche Backup-Zeit und die Standortbedingungen, um ein maßgeschneidertes Angebot für eine USV oder Batterielösung zu erhalten.
What is the rated capacity of the DAXIN 3H3 80kVA?
The reference model is rated at 80kVA / 64kW.
What does 3/3 phase mean?
It means the UPS uses three-phase input and provides three-phase output.
What is the mains-to-battery transfer time?
The reference specification lists 0ms mains-to-battery transfer.
What output voltage does the UPS support?
The reference configuration supports 380/400/415VAC three-phase output.
How should an 80kVA UPS be sized?
UPS sizing should consider actual load in kW and kVA, power factor, peak demand, future expansion, required operating margin and backup-time requirements.
Can the 80kVA UPS support parallel redundancy?
Parallel and redundancy capabilities depend on the selected configuration and must be confirmed against the approved technical specification before system design.