Mô tả
What Is the DAXIN 3H3 120kVA 3/3 Phase Online UPS?
The DAXIN 3H3 120kVA is a 120kVA/96kW low-frequency online UPS designed for high-capacity critical applications requiring three-phase input and three-phase output power protection.
Its 3/3 phase architecture is intended for facilities where both the incoming electrical supply and protected critical loads operate on three-phase power.
The reference configuration supports 380/400/415VAC three-phase input and output, 0ms mains-to-battery transfer and greater than 90% efficiency.
Battery configuration, bypass, communications, redundancy requirements and other project parameters should be confirmed according to the connected load, required backup time and approved DAXIN technical proposal.
Những lợi ích chính
- 120kVA / 96kW Capacity: Designed for high-capacity critical three-phase loads in industrial and infrastructure applications.
- 3/3 Phase Architecture: Three-phase input and three-phase output support large three-phase electrical systems.
- Low-Frequency UPS Design: Intended for demanding industrial and infrastructure critical-power applications.
- Online Power Protection: Provides continuous conditioned power for sensitive and mission-critical loads.
- Chuyển đổi từ nguồn điện lưới sang pin trong 0 ms: Maintains output during utility-to-battery transition according to the reference specification.
- Configurable Battery System: Battery configuration and runtime can be engineered according to load and backup-time requirements.
- Monitoring and Protection: Display, alarm, protection and communication functions support system operation and maintenance.
- Project-Based Configuration: Parallel, redundancy, bypass and communication capabilities must be confirmed for the selected configuration.
What Does 3/3 Phase Mean in a UPS?
A 3/3 phase UPS uses three-phase AC power at the input and supplies three-phase AC power at the output.
This architecture is commonly used for high-capacity critical loads in data centers, industrial facilities, power infrastructure, healthcare systems and transportation applications.
The DAXIN 3H3 120kVA uses this three-phase input and three-phase output configuration for large critical-power applications.
DAXIN 3H3 120kVA Key Specifications
| Tham số | 3H3-120kVA |
|---|---|
| Công suất định mức | 120kVA / 96kW |
| Giai đoạn | Đầu vào ba pha / Đầu ra ba pha |
| Điện áp đầu vào | 3×380 / 400 / 415VAC |
| Dải điện áp đầu vào | 285–475VAC |
| Tần số đầu vào | 46–54Hz @ 50Hz; 56–64Hz @ 60Hz |
| Điện áp đầu ra | 380 / 400 / 415VAC |
| Battery-Mode Frequency | 50/60Hz ±0.1Hz |
| Độ méo hài tổng (THD) đầu ra | <3% Linear / <5% Non-linear |
| Mains-to-Battery Transfer | 0 ms |
| Hiệu quả | >90% |
| Loại pin | Sealed Lead-Acid, Maintenance-Free |
| Số lượng pin | 29 / 30 / 31 / 32 pcs, 12V Series |
| Kích thước | 975 × 554 × 1286 mm |
| Trọng lượng tịnh | 573 kg |
| Nhiệt độ hoạt động | 0–55°C |
| Độ ẩm tương đối | <95%, Non-Condensing |
| Độ cao hoạt động | <1.000 m |
| Giao tiếp | RS-232 / USB |
| SNMP | Optional |
Thông tin về sản phẩm và tài liệu tham khảo kỹ thuật

Các ứng dụng điển hình
- Các trung tâm dữ liệu và cơ sở máy chủ quy mô lớn
- Industrial plants and manufacturing systems
- Power and utility infrastructure
- Telecom core facilities
- Hospitals and critical healthcare systems
- Transportation and tunnel infrastructure
- Commercial and public infrastructure
- Other high-capacity three-phase critical loads
How to Select a 120kVA Three-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.
For a 3/3 phase UPS, confirm that both the site electrical supply and protected critical loads require three-phase power.
Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communications and installation conditions for project configuration.
Các câu hỏi thường gặp
Sản phẩm này có thể được tùy chỉnh cho một dự án cụ thể không?
Đúng vậy. Có thể rà soát các yếu tố như cấu hình điện, thời lượng hoạt động của pin, hệ thống truyền thông, chế độ bypass, cách bố trí tủ và các phụ kiện của dự án để đảm bảo phù hợp với các yêu cầu tại hiện trường.
Tất cả các chỉ số kỹ thuật có được áp dụng chung cho toàn bộ loạt phim không?
Không. Các thông số kỹ thuật và chức năng có thể khác nhau tùy theo từng mẫu và cấu hình. Vui lòng tham khảo bảng thông số kỹ thuật dành riêng cho dự án làm tài liệu tham khảo chính thức.
DAXIN ENERGY có thể hỗ trợ việc lựa chọn hệ thống không?
Vâng. Vui lòng cung cấp danh sách tải, pha và điện áp, thời gian hoạt động yêu cầu, mục tiêu dự phòng, các yêu cầu về truyền thông và môi trường lắp đặt.
Yêu cầu cấu hình dự án
Vui lòng gửi dữ liệu tải, sơ đồ mạch đơn, thời gian dự phòng cần thiết và điều kiện tại hiện trường để nhận được đề xuất về bộ lưu điện (UPS) hoặc ắc-quy phù hợp với nhu cầu của quý khách.
What is the rated capacity of the DAXIN 3H3 120kVA?
The reference model is rated at 120kVA / 96kW.
What does 3/3 phase mean?
It means the UPS uses three-phase input and provides three-phase output.
What is the mains-to-battery transfer time?
The reference specification lists 0ms mains-to-battery transfer.
What output voltage does the UPS support?
Cấu hình tham chiếu hỗ trợ đầu ra ba pha 380/400/415 VAC.
Can the battery runtime be customized?
Battery configuration and runtime should be selected according to connected load, required backup duration and the approved system configuration.
Does the 120kVA UPS support parallel redundancy?
Parallel and redundancy capabilities depend on the selected configuration and must be confirmed against the approved technical specification before system design.