11-H3kVA Standard Online Double-Conversion UPS – 3000VA/2700W Power Protection

The 11-H3kVA Standard Model is a high-performance 3kVA online double-conversion UPS featuring DSP technology, a 0.9 output power factor, and a wide input voltage range (90V-300V). Ideal for government, telecom, and medical applications. Includes smart battery management and optional SNMP monitoring.

Description

11-H3kVA (Standard Model)

I. Power Range: 3kVA

Working Mode: Single-phase input / Single-phase output, Online Double-Conversion.
Applications: Widely used across various sectors including government, finance, telecommunications, education, transportation, meteorology, broadcasting, taxation, healthcare, energy, and power industries.

Product Features:

  • True Online Double-Conversion: Provides continuous, high-quality power by isolating the load from utility irregularities.

  • Microprocessor Control: Ensures high reliability and precise operation through advanced digital management.

  • Input Power Factor Correction: Optimizes energy usage and reduces harmonic distortion on the grid.

  • High Output Power Factor: Output Power Factor reaches up to 0.9, providing more real power for connected loads.

  • Wide Input Voltage Range (90V – 300V): Capable of operating in unstable power environments without switching to battery mode.

  • Efficient Frequency Converter Mode: Supports conversion between 50Hz and 60Hz to meet specialized equipment needs.

  • Generator Compatible: Works seamlessly with backup generator systems.

  • Enhanced Monitoring Options: Optional SNMP card allows for standalone monitoring or integrated management via USB and RS232 ports.

  • User-Friendly LCD Display: Offers simple operation and comprehensive, real-time monitoring of UPS status.

  • ECO Mode: Provides high-efficiency energy-saving operation to reduce electricity costs.

  • Emergency Power Off (EPO): Allows for immediate shutdown in the event of an emergency.

  • DSP Technology: Built on advanced Digital Signal Processing technology; optional maintenance bypass switch available.

  • Smart Battery Charger Design: Optimizes battery performance and significantly extends battery lifespan.

  • Isolation Transformer: Optional built-in isolation transformer for enhanced electrical protection.

II. Technical Notes:

Item 11-H1kVA 11-H2kVA 11-H3kVA 11-H6kVA 11-H10kVA
Model 11-H1kVA 11-H2kVA 11-H3kVA 11-H6kVA 11-H10kVA
Capacity 1000VA/900W 2000VA/1800W 3000VA/2700W 6000VA/5400W 10000VA/9000W
### Input
Phase Single-phase grounded Single-phase grounded Single-phase grounded Single-phase grounded Single-phase grounded
Minimum Transfer Voltage colspan=”3″ 160VAC/140VAC/120VAC/110VAC ±5% (Ambient temp <35℃; Load Ratio: 100%-80%-80%-70%-70%-70%-60%-60%-0) colspan=”2″ 50% Load: 110VAC ±3%;

100% Load: 176VAC ±3%

Minimum Restore Voltage colspan=”3″ 195VAC/175VAC/155VAC/135VAC ±5% (Ambient temp <35℃; Load Ratio: 100%-80%-80%-70%-70%-60%-60%-0) colspan=”2″ Minimum transfer voltage +10V
Maximum Transfer Voltage colspan=”3″ 300VAC ±5% colspan=”2″ 300VAC ±3%
Maximum Restore Voltage colspan=”3″ 290VAC ±5% colspan=”2″ Maximum transfer voltage -10V
Frequency Range colspan=”3″ 40Hz ~ 70Hz colspan=”2″ 46Hz~54Hz (@50Hz System);

56Hz~64Hz (@60Hz System)

Input Power Factor colspan=”3″ ≥0.99 @ 220-230-240VAC colspan=”2″ N/A
### Output
Output Voltage colspan=”3″ 208/220/230/240VAC ±1% colspan=”2″ 208/220/230/240VAC ±1%
Frequency Range (Synchronization) colspan=”3″ 47-53Hz or 57-63Hz colspan=”2″ 46-54Hz or 56-64Hz
Frequency Range (Battery Mode) colspan=”3″ 50±0.25Hz or 60±0.3Hz colspan=”2″ 50±0.1Hz or 60±0.1Hz
Crest Factor colspan=”5″ 3:1
Total Harmonic Distortion (THD) colspan=”3″ ≤3% THD (Linear Load); ≤6% THD (Non-linear Load) colspan=”2″ ≤3% THD (Linear Load); ≤5% THD (Non-linear Load)
Overload Capacity colspan=”3″ Temp<35℃:

105%-110%: Auto-restart after 10s fault, recover output within 1s when input normalizes

110%-130%: Auto-shutdown after 3 mins, recover after 3s when input normalizes

>150%: Instant UPS shutdown

colspan=”2″ 100%~110%: 30 Minutes

110%~130%: 5 Minutes

>130%: 10 Seconds

Transfer Time (Mains to Battery) colspan=”3″ 0ms colspan=”2″ 0ms
Transfer Time (Inverter to Bypass) colspan=”3″ 4ms (Standard Condition) colspan=”2″ 0ms
Waveform (Battery Mode) colspan=”3″ Pure Sine Wave colspan=”2″ N/A
### Efficiency
Mains Mode 88% 89% 90% 92% 93%
Battery Mode 83% 87% 88% 90% 91%
### Battery
Standard Unit (S)
Battery Type colspan=”3″ 12V/7Ah colspan=”2″ 12V/7Ah
Battery Quantity 2 4 6 12 16
Charging Current colspan=”3″ 1.0A colspan=”2″ Preset: 1.0A ±10%, Max: 1A/2A
Long-run Unit (L)
Battery Type colspan=”5″ 12V/AH (Customized per buyer request)
Battery Quantity 3 3 8 colspan=”2″ Model-dependent
Charging Current colspan=”3″ 1A/2A/4A/6A colspan=”2″ 1A/2A/4A/6A (Adjustable);

6A only applicable for 16-cell battery pack

### Physical Specifications
Standard Unit
Dimension (D×W×H, mm) 282×145×220 397×145×220 421×190×318 369×190×688 442×190×688
Net Weight (kg) 9.8 17 26.2 51 55
Long-run Unit
Dimension (D×W×H, mm) 282×145×220 397×145×220 421×190×318 369×190×318 442×190×318
Net Weight (kg) 4.4 6.8 7.4 12 15
### Operating Environment
Operating Humidity colspan=”3″ 20-90% RH, 0-40℃ (Non-condensing) colspan=”2″ <95% RH, Non-condensing
Noise colspan=”3″ <50dB @ 1 Meter <55dB @ 1 Meter <58dB @ 1 Meter
Operating Temperature colspan=”3″ N/A colspan=”2″ 0 ~ 40℃ (Battery lifespan shortened above 25℃ ambient temp)
### Control & Management
Intelligent RS-232/USB colspan=”5″ Compatible with Windows 2000/2003/XP/Vista/2008, Windows7/8, Linux & MAC
Optional SNMP Card colspan=”5″ Supports SNMP network management & remote monitoring

 

  • Derating Rules for 1-3kVA Models: Output power will be derated to 80% of capacity when the UPS is set to CVCF (Constant Voltage Constant Frequency) mode or when the output voltage is configured to 208VAC.

  • Derating Rules for 6/10kVA Models: Output power will be derated to 60% in CVCF mode and to 90% when the output voltage is set to 208VAC.

  • Parallel Redundancy: The standard models listed above currently do not support parallel redundancy.

  • Voltage Support: Output voltage settings of 200/208/220/230/240VAC are only applicable to Long-run (L) models.

  • For 1-3kVA UPS: The output power is derated to 80% when operating in CVCF (Constant Voltage Constant Frequency) mode or when the output voltage is set to 208VAC.

  • For 6/10kVA UPS: The output power is derated to 60% in CVCF mode and to 90% when the output voltage is set to 208VAC.

  • The standard models mentioned above currently do not support parallel redundancy.

  • The voltage settings of 200/208/220/230/240VAC are only applicable to long-run models.

Reviews

There are no reviews yet.

Be the first to review “11-H3kVA Standard Online Double-Conversion UPS – 3000VA/2700W Power Protection”

Your email address will not be published. Required fields are marked *