Description
What Is the DAXIN RM33 180kVA Modular Online UPS?
The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.
Its modular cabinet architecture integrates power modules, centralized control, protection and service access within a scalable UPS platform, allowing installed capacity and redundancy to be configured according to project requirements.
The RM33 series supports 3 × 380/400/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.
Battery configuration, backup runtime, redundancy architecture, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.
DAXIN RM33-180kVA Key Specifications
| Paramètre | Caractéristiques techniques |
|---|---|
| Modèle | RM33-180kVA |
| UPS Type | Modular Online UPS |
| Phase | Three-Phase Input / Three-Phase Output |
| Cabinet Capacity | 180kW or 120kW configuration |
| Type de batterie | External Battery Pack |
| Battery Cabinet Capacity | 30 kVA / 30 kW |
| Optional Battery Cabinets | Up to 6 |
| Tension d'entrée | 3 × 380/400/415VAC (3PH+N) |
| Fréquence d'entrée | 50/60Hz Auto-Detect |
| Plage de fréquences d'entrée | 40–70Hz |
| Facteur de puissance d'entrée | ≥0.99 @ 100% Load |
| Input Current THDi | <2% @ 100% Load |
| Tension de sortie | 3 × 380/400/415VAC (3PH+N) |
| Static Voltage Stability | ≤±0.3% Typical Load |
| Dynamic Voltage Stability | ≤±3% Typical Load |
| Fréquence de sortie | 50/60 Hz |
| Gamme de fréquences | 46–54Hz or 56–64Hz |
| THD de sortie | ≤1% Linear / ≤2% Non-linear |
| Efficacité | Jusqu'à 96,51 TP3T |
| Dimensions | 1100 × 600 × 1475mm |
| Poids net | 195 / 223kg |
| Température de fonctionnement | 0 à 40 °C |
| Altitude | <1000m at Rated Power |
| Indice de protection | IP20 |
| Communication | RS-232 / USB |
| Gestion du réseau | SNMP (en option) |
Principaux avantages
- 180kVA Modular UPS Platform: Designed for scalable three-phase critical-power applications in data centers, telecom and industrial facilities.
- Scalable Modular Architecture: Power-module configuration can be planned according to current load, redundancy requirements and future expansion.
- Three-Phase Power Protection: Supports 3 × 380/400/415VAC three-phase input and output.
- Low Input Harmonic Distortion: Input current THDi below 2% at full load helps reduce upstream electrical impact.
- High Input Power Factor: Input power factor is at least 0.99 at 100% load.
- High Efficiency: System efficiency is specified at up to 96.5%.
- External Battery Configuration: Battery capacity and backup runtime can be engineered according to project requirements.
- Remote Monitoring: RS-232/USB communication is supported, with optional SNMP network management.
What Is a Modular UPS System?
A modular UPS system uses multiple power modules within a common UPS cabinet instead of relying on a single fixed-capacity power stage.
This architecture allows capacity, redundancy and maintenance strategy to be planned according to the critical load, required availability and future expansion.
The DAXIN RM33 series combines modular power architecture, centralized control, external battery configurations and network-management options for scalable critical-power applications.
How Should an 180kVA Modular UPS Be Sized?
An 180kVA modular UPS should be sized according to the actual critical load in kW and kVA, load power factor, required redundancy, expected future expansion and battery autonomy.
Modular system design should also consider the number and rating of installed power modules, bypass architecture, upstream and downstream protection, communication requirements and maintenance strategy.
DAXIN ENERGY can review the load list, single-line diagram, required backup time and redundancy target before confirming the final RM33 system configuration.
Présentations des produits et documentation technique

Applications typiques
- Centres de données et salles de serveurs
- Telecom core facilities and network infrastructure
- Industrial automation and manufacturing plants
- Financial and banking facilities
- Healthcare and medical infrastructure
- Transportation and public infrastructure
- Enterprise IT facilities
- Other scalable mission-critical power systems
Sélection et planification du projet
Avant de passer commande, vérifiez que la puissance nominale exacte, la phase d'entrée/sortie, la tension, la fréquence, le facteur de puissance, la tension de la batterie, l'autonomie, le contournement, les communications, les dimensions, les limites environnementales et la méthode d'installation correspondent bien au modèle sélectionné et aux plans du projet.
Foire aux questions
Ce produit peut-il être configuré pour un projet spécifique ?
Oui. La configuration électrique, l'autonomie de la batterie, les systèmes de communication, le contournement, la disposition des armoires et les accessoires du projet peuvent être examinés en fonction des exigences du site.
Les notes techniques sont-elles toutes communes à l'ensemble de la série ?
Non. Les caractéristiques techniques et les fonctions varient selon le modèle et la configuration. Veuillez vous référer à la fiche technique spécifique au projet comme référence définitive.
DAXIN ENERGY peut-elle vous aider à choisir un système ?
Oui. Veuillez nous fournir la liste des charges, la phase et la tension, la durée de fonctionnement requise, l'objectif de redondance, les exigences en matière de communication et l'environnement d'installation.
Demander une configuration de projet
Envoyez-nous les données de charge, le schéma unifilaire, le temps de secours requis et les conditions sur site afin de recevoir une proposition sur mesure concernant un onduleur ou une batterie.
What is the DAXIN RM33 180kVA?
The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power applications.
What input and output voltage does it support?
The reference specification lists 3 × 380/400/415VAC three-phase input and output.
What are the input power factor and THDi?
The RM33 reference specification lists an input power factor of at least 0.99 at full load and input current THDi below 2%.
What is the efficiency of the RM33 modular UPS?
The reference specification lists system efficiency up to 96.5%. Actual efficiency depends on load and system configuration.
Does the RM33 support remote monitoring?
Yes. RS-232/USB communication is supported, with optional SNMP network management.
Can the RM33-180kVA system be configured for redundancy?
Yes, modular architecture allows redundancy requirements to be considered during system design. Final module quantity, redundancy architecture and installed capacity should be confirmed in the approved technical proposal.









Avis
Il n’y a pas encore d’avis.