Descripción
What Is the DAXIN RM33 180kVA Modular Online UPS?
The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.
Its modular cabinet architecture integrates power modules, centralized control, protection and service access within a scalable UPS platform, allowing installed capacity and redundancy to be configured according to project requirements.
The RM33 series supports 3 × 380/400/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.
Battery configuration, backup runtime, redundancy architecture, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.
DAXIN RM33-180kVA Key Specifications
| Parámetro | Especificaciones |
|---|---|
| Modelo | RM33-180kVA |
| UPS Type | Modular Online UPS |
| Fase | Three-Phase Input / Three-Phase Output |
| Cabinet Capacity | 180kW or 120kW configuration |
| Tipo de batería | External Battery Pack |
| Battery Cabinet Capacity | 30 kVA / 30 kW |
| Optional Battery Cabinets | Up to 6 |
| Tensión de entrada | 3 × 380/400/415VAC (3PH+N) |
| Frecuencia de entrada | 50/60Hz Auto-Detect |
| Rango de frecuencias de entrada | 40–70Hz |
| Factor de potencia de entrada | ≥0.99 @ 100% Load |
| Input Current THDi | <2% @ 100% Load |
| Tensión de salida | 3 × 380/400/415VAC (3PH+N) |
| Static Voltage Stability | ≤±0.3% Typical Load |
| Dynamic Voltage Stability | ≤±3% Typical Load |
| Frecuencia de salida | 50/60Hz |
| Rango de frecuencias | 46–54Hz or 56–64Hz |
| Distorsión armónica total (THD) de salida | ≤1% Linear / ≤2% Non-linear |
| Eficiencia | Up to 96.5% |
| Dimensiones | 1100 × 600 × 1475mm |
| Peso neto | 195 / 223kg |
| Temperatura de funcionamiento | 0–40°C |
| Altitud | <1000m at Rated Power |
| Índice de protección | IP20 |
| Comunicación | RS-232 / USB |
| Network Management | SNMP opcional |
Ventajas principales
- 180kVA Modular UPS Platform: Designed for scalable three-phase critical-power applications in data centers, telecom and industrial facilities.
- Scalable Modular Architecture: Power-module configuration can be planned according to current load, redundancy requirements and future expansion.
- Three-Phase Power Protection: Supports 3 × 380/400/415VAC three-phase input and output.
- Low Input Harmonic Distortion: Input current THDi below 2% at full load helps reduce upstream electrical impact.
- High Input Power Factor: Input power factor is at least 0.99 at 100% load.
- High Efficiency: System efficiency is specified at up to 96.5%.
- External Battery Configuration: Battery capacity and backup runtime can be engineered according to project requirements.
- Remote Monitoring: RS-232/USB communication is supported, with optional SNMP network management.
What Is a Modular UPS System?
A modular UPS system uses multiple power modules within a common UPS cabinet instead of relying on a single fixed-capacity power stage.
This architecture allows capacity, redundancy and maintenance strategy to be planned according to the critical load, required availability and future expansion.
The DAXIN RM33 series combines modular power architecture, centralized control, external battery configurations and network-management options for scalable critical-power applications.
How Should an 180kVA Modular UPS Be Sized?
An 180kVA modular UPS should be sized according to the actual critical load in kW and kVA, load power factor, required redundancy, expected future expansion and battery autonomy.
Modular system design should also consider the number and rating of installed power modules, bypass architecture, upstream and downstream protection, communication requirements and maintenance strategy.
DAXIN ENERGY can review the load list, single-line diagram, required backup time and redundancy target before confirming the final RM33 system configuration.
Descripciones de productos y referencia técnica

Aplicaciones típicas
- Centros de datos y salas de servidores
- Telecom core facilities and network infrastructure
- Industrial automation and manufacturing plants
- Financial and banking facilities
- Healthcare and medical infrastructure
- Transportation and public infrastructure
- Enterprise IT facilities
- Other scalable mission-critical power systems
Selección y planificación del proyecto
Antes de realizar el pedido, compruebe que la potencia nominal exacta, la fase de entrada/salida, la tensión, la frecuencia, el factor de potencia, la tensión de la batería, el tiempo de autonomía, el modo de derivación, las comunicaciones, las dimensiones, los límites ambientales y el método de instalación se ajusten al modelo seleccionado y a los planos del proyecto.
Preguntas frecuentes
¿Se puede configurar este producto para un proyecto concreto?
Sí. La configuración eléctrica, la autonomía de la batería, las comunicaciones, el sistema de derivación, la disposición de los armarios y los accesorios del proyecto pueden revisarse en función de los requisitos de la instalación.
¿Se aplican todas las clasificaciones técnicas a toda la serie?
No. Las características técnicas y las funciones varían según el modelo y la configuración. Utilice la ficha técnica específica del proyecto como referencia definitiva.
¿Puede DAXIN ENERGY ayudar en la selección del sistema?
Sí. Facilite la lista de cargas, la fase y la tensión, el tiempo de funcionamiento requerido, el objetivo de redundancia, los requisitos de comunicación y el entorno de instalación.
Solicitar una configuración de proyecto
Envíenos los datos de carga, el esquema unifilar, el tiempo de autonomía necesario y las condiciones del emplazamiento para recibir una propuesta personalizada de SAI o baterías.
What is the DAXIN RM33 180kVA?
The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power applications.
What input and output voltage does it support?
The reference specification lists 3 × 380/400/415VAC three-phase input and output.
What are the input power factor and THDi?
The RM33 reference specification lists an input power factor of at least 0.99 at full load and input current THDi below 2%.
What is the efficiency of the RM33 modular UPS?
The reference specification lists system efficiency up to 96.5%. Actual efficiency depends on load and system configuration.
Does the RM33 support remote monitoring?
Yes. RS-232/USB communication is supported, with optional SNMP network management.
Can the RM33-180kVA system be configured for redundancy?
Yes, modular architecture allows redundancy requirements to be considered during system design. Final module quantity, redundancy architecture and installed capacity should be confirmed in the approved technical proposal.









Valoraciones
No hay valoraciones aún.