Açıklama
DAXIN 10kVA Low-Frequency Online UPS Video
Watch the DAXIN 10kVA low-frequency online UPS in operation. Contact our engineering team for specifications, backup time calculation, battery configuration, pricing, and OEM/ODM support.
What Is the DAXIN 1/1 10K(L) 10kVA Online UPS?
The DAXIN 1/1 10K(L) is a 10kVA/8kW online UPS designed for critical applications requiring single-phase input and single-phase output power protection.
Its 1/1 phase architecture matches facilities where both the incoming utility supply and protected critical loads operate on single-phase power.
The reference configuration provides 208/220/230VAC output, ±1% voltage regulation, 0ms mains-to-battery transfer, 88% AC-mode efficiency and 92% battery-mode efficiency.
The UPS supports configurable 16/18-battery operation, RS-232/USB communication and optional SNMP network management. Battery configuration, runtime and project options should be selected according to the connected load and required backup duration.
Başlıca Avantajlar
- 10 kVA / 8 kW Kapasite: Designed for critical single-phase loads requiring up to 8kW rated active power.
- 1/1 Phase Architecture: Single-phase input and single-phase output match common single-phase critical-power applications.
- Çevrimiçi Güç Koruması: Provides continuous power conditioning for sensitive electrical and electronic loads.
- 0ms Transfer Time: Maintains output during mains-to-battery transition according to the reference specification.
- Stable Output: Supports 208/220/230VAC output with ±1% voltage regulation.
- Yapılandırılabilir Pil Sistemi: Supports 16/18-battery configurations with charging options according to project requirements.
- Communication and Monitoring: RS-232/USB communication with optional SNMP network management.
- Proje Tabanlı Yapılandırma: Battery runtime and other system requirements can be reviewed according to the connected load and site conditions.
DAXIN 1/1 10K(L) Key Specifications
| Parametre | 1/1 10K(L) |
|---|---|
| Nominal Kapasite | 10kVA / 8kW |
| Aşama | Single Phase Input / Single Phase Output |
| Çıkış Gerilimi | 208 / 220 / 230VAC |
| Gerilim Düzenlemesi | ±1% |
| Battery-Mode Frequency | 50Hz ±0.1Hz or 60Hz ±0.1Hz |
| Tepe Faktörü | 3:1 Max |
| Çıkış THD'si | ≤3% Linear / ≤5% Non-linear |
| Mains-to-Battery Transfer | 0 ms |
| Inverter-to-Bypass Transfer | 0 ms |
| AC Modunda Verimlilik | 88% |
| Pil Modunda Verimlilik | 92% |
| Pil Adedi | 16 / 18 pcs |
| Maximum Charging Current | 8A |
| Boyutlar | 562 × 250 × 830 mm |
| Net Ağırlık | 86 kg |
| Çalışma Sıcaklığı | 0–50°C |
| Bağıl Nem | <95%, Non-Condensing |
| Çalışma İrtifası | <1000m |
| Gürültü | <58 dB @ 1 m |
| İletişim | RS-232 / USB |
| SNMP | Optional |
What Does 1/1 Phase Mean in a UPS?
A 1/1 phase UPS uses single-phase AC power at the input and supplies single-phase AC power at the output.
This configuration is commonly used for critical single-phase loads in server rooms, telecom systems, medical equipment, security systems, financial infrastructure and industrial control applications.
The DAXIN 1/1 10K(L) uses this architecture for applications where both the facility supply and protected equipment require single-phase power.
Ürün Görünümleri ve Teknik Referans

Tipik Uygulamalar
- Server rooms and IT equipment
- Telecom and communication systems
- Endüstriyel kontrol ve otomasyon ekipmanları
- Medical and diagnostic equipment
- Bankacılık ve finans sistemleri
- Güvenlik ve gözetim sistemleri
- Transportation and infrastructure equipment
- Other critical single-phase electrical loads
How to Select the Right 10kVA Single-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, required backup time, battery configuration, startup or peak load, communication requirements and installation environment.
For the DAXIN 1/1 10K(L), confirm that the site provides the required single-phase input supply and that the protected equipment requires single-phase output.
Provide DAXIN ENERGY with the load list, site voltage, required runtime, battery requirements, communication interfaces and installation conditions to determine the appropriate UPS configuration.
Sık Sorulan Sorular
Bu ürün belirli bir projeye göre özelleştirilebilir mi?
Evet. Elektrik konfigürasyonu, pil çalışma süresi, iletişim, baypas, kabin düzeni ve proje aksesuarları, tesisin gereksinimlerine göre gözden geçirilebilir.
Tüm teknik derecelendirmeler serinin tamamında ortak mıdır?
Hayır. Teknik özellikler ve işlevler modele ve yapılandırmaya göre değişiklik gösterir. Nihai referans olarak projeye özgü teknik veri sayfasını kullanın.
DAXIN ENERGY, sistem seçiminde destek sağlayabilir mi?
Evet. Yük listesini, faz ve gerilimi, gerekli çalışma süresini, yedeklilik hedefini, iletişim gereksinimlerini ve kurulum ortamını belirtin.
Proje Yapılandırması Talep Et
Özel olarak hazırlanmış bir UPS veya akü teklifi almak için yük verilerini, tek hat şemasını, gerekli yedekleme süresini ve saha koşullarını bize gönderin.
What is the rated capacity of the DAXIN 1/1 10K(L)?
Referans modelin nominal gücü 10 kVA / 8 kW’tır.
What does 1/1 phase mean?
It means the UPS uses single-phase input and provides single-phase output.
Elektrik kesintisi sırasında aktarım süresi ne kadardır?
The supplied reference specification lists 0ms mains-to-battery transfer.
UPS hangi çıkış gerilimini destekliyor?
The reference configuration supports 208/220/230VAC output with ±1% regulation.
Pil ömrü özelleştirilebilir mi?
Yes. Battery runtime depends on connected load, battery configuration, battery condition and required backup duration.
UPS, uzaktan izleme özelliğini destekliyor mu?
The reference configuration supports RS-232/USB communication, with optional SNMP network management.









Yorumlar