The DAXIN 1/1 10K(L) is a 10kVA/8kW low-frequency online UPS designed for single-phase input and single-phase output critical power applications. Featuring 0ms transfer to battery operation, 208/220/230VAC output, configurable 16/18-battery operation, RS-232/USB communication and optional SNMP monitoring, it is suitable for control systems, telecom, healthcare, finance, transportation, security and other critical single-phase loads.

Angebot anfordern & technischer Support

Senden Sie uns Ihre Anfrage mit Angaben zur Menge und den technischen Anforderungen. Unser Ingenieurteam wird Ihnen daraufhin eine passende Konfiguration vorschlagen.

Beschreibung

DAXIN 10kVA Low-Frequency Online UPS Video

Watch the DAXIN 10kVA low-frequency online UPS in operation. Contact our engineering team for specifications, backup time calculation, battery configuration, pricing, and OEM/ODM support.

What Is the DAXIN 1/1 10K(L) 10kVA Online UPS?

The DAXIN 1/1 10K(L) is a 10kVA/8kW online UPS designed for critical applications requiring single-phase input and single-phase output power protection.

Its 1/1 phase architecture matches facilities where both the incoming utility supply and protected critical loads operate on single-phase power.

The reference configuration provides 208/220/230VAC output, ±1% voltage regulation, 0ms mains-to-battery transfer, 88% AC-mode efficiency and 92% battery-mode efficiency.

The UPS supports configurable 16/18-battery operation, RS-232/USB communication and optional SNMP network management. Battery configuration, runtime and project options should be selected according to the connected load and required backup duration.

Wichtigste Vorteile

    • 10kVA / 8kW Capacity: Designed for critical single-phase loads requiring up to 8kW rated active power.
    • 1/1 Phase Architecture: Single-phase input and single-phase output match common single-phase critical-power applications.
    • Online Power Protection: Provides continuous power conditioning for sensitive electrical and electronic loads.
    • 0ms Transfer Time: Maintains output during mains-to-battery transition according to the reference specification.
    • Stable Output: Supports 208/220/230VAC output with ±1% voltage regulation.
    • Configurable Battery System: Supports 16/18-battery configurations with charging options according to project requirements.
    • Communication and Monitoring: RS-232/USB communication with optional SNMP network management.
    • Project-Based Configuration: Battery runtime and other system requirements can be reviewed according to the connected load and site conditions.

DAXIN 1/1 10K(L) Key Specifications

Parameter1/1 10K(L)
Nennkapazität10kVA / 8kW
PhaseSingle Phase Input / Single Phase Output
Ausgangsspannung208 / 220 / 230VAC
Spannungsregelung±1%
Battery-Mode Frequency50 Hz ±0,1 Hz oder 60 Hz ±0,1 Hz
Scheitelfaktor3:1 Max
Ausgangs-THD≤3% Linear / ≤5% Non-linear
Mains-to-Battery Transfer0 ms
Inverter-to-Bypass Transfer0 ms
AC Mode Efficiency88%
Battery Mode Efficiency92%
Anzahl der Batterien16 / 18 pcs
Maximaler Ladestrom8A
Abmessungen562 × 250 × 830 mm
Nettogewicht86 kg
Betriebstemperatur0–50°C
Relative Luftfeuchtigkeit<95%, Non-Condensing
Betriebshöhe<1000 m
Lärm<58 dB in 1 m Entfernung
KommunikationRS-232 / USB
SNMPOptional

What Does 1/1 Phase Mean in a UPS?

A 1/1 phase UPS uses single-phase AC power at the input and supplies single-phase AC power at the output.

This configuration is commonly used for critical single-phase loads in server rooms, telecom systems, medical equipment, security systems, financial infrastructure and industrial control applications.

The DAXIN 1/1 10K(L) uses this architecture for applications where both the facility supply and protected equipment require single-phase power.

Produktansichten und technische Informationen

Product View for DAXIN 1/1 10K(L) Low-Frequency 1/1 Phase UPS.

DAXIN 6kVA and 10kVA Single-Phase Online UPS Technical Specifications
Technical specifications for DAXIN 6kVA and 10kVA single-phase online UPS models.

Typische Anwendungsbereiche

  • Server rooms and IT equipment
  • Telecom and communication systems
  • Industrial control and automation equipment
  • Medical and diagnostic equipment
  • Bank- und Finanzsysteme
  • Security and surveillance systems
  • Transportation and infrastructure equipment
  • Other critical single-phase electrical loads

How to Select the Right 10kVA Single-Phase UPS

Select the UPS according to the actual connected load in kW and kVA, input and output voltage, required backup time, battery configuration, startup or peak load, communication requirements and installation environment.

For the DAXIN 1/1 10K(L), confirm that the site provides the required single-phase input supply and that the protected equipment requires single-phase output.

Provide DAXIN ENERGY with the load list, site voltage, required runtime, battery requirements, communication interfaces and installation conditions to determine the appropriate UPS configuration.

Häufig gestellte Fragen

Kann dieses Produkt für ein bestimmtes Projekt angepasst werden?

Ja. Die elektrische Konfiguration, die Batterielaufzeit, die Kommunikationsfunktionen, der Bypass, die Gehäuseanordnung und das Projektzubehör können anhand der Anforderungen vor Ort überprüft werden.

Gelten alle technischen Bewertungen für die gesamte Serie?

Nein. Die Nennleistungen und Funktionen variieren je nach Modell und Konfiguration. Als maßgebliche Grundlage dient das projektspezifische technische Datenblatt.

Kann DAXIN ENERGY bei der Systemauswahl helfen?

Ja. Bitte geben Sie die Lastliste, die Phase und die Spannung, die erforderliche Laufzeit, das Redundanzziel, die Kommunikationsanforderungen und die Installationsumgebung an.

Projektkonfiguration anfordern

Senden Sie uns die Lastdaten, das Einliniendiagramm, die erforderliche Backup-Zeit und die Standortbedingungen, um ein maßgeschneidertes Angebot für eine USV oder Batterielösung zu erhalten.

What is the rated capacity of the DAXIN 1/1 10K(L)?

The reference model is rated at 10kVA / 8kW.

What does 1/1 phase mean?

It means the UPS uses single-phase input and provides single-phase output.

Wie lange dauert die Umschaltung bei einem Stromausfall?

The supplied reference specification lists 0ms mains-to-battery transfer.

What output voltage does the UPS support?

The reference configuration supports 208/220/230VAC output with ±1% regulation.

Can the battery runtime be customized?

Yes. Battery runtime depends on connected load, battery configuration, battery condition and required backup duration.

Unterstützt die USV eine Fernüberwachung?

The reference configuration supports RS-232/USB communication, with optional SNMP network management.