คำอธิบาย
DAXIN 10kVA Low-Frequency Online UPS Video
Watch the DAXIN 10kVA low-frequency online UPS in operation. Contact our engineering team for specifications, backup time calculation, battery configuration, pricing, and OEM/ODM support.
What Is the DAXIN 1/1 10K(L) 10kVA Online UPS?
The DAXIN 1/1 10K(L) is a 10kVA/8kW online UPS designed for critical applications requiring single-phase input and single-phase output power protection.
Its 1/1 phase architecture matches facilities where both the incoming utility supply and protected critical loads operate on single-phase power.
The reference configuration provides 208/220/230VAC output, ±1% voltage regulation, 0ms mains-to-battery transfer, 88% AC-mode efficiency and 92% battery-mode efficiency.
The UPS supports configurable 16/18-battery operation, RS-232/USB communication and optional SNMP network management. Battery configuration, runtime and project options should be selected according to the connected load and required backup duration.
ประโยชน์หลัก
- 10kVA / 8kW Capacity: Designed for critical single-phase loads requiring up to 8kW rated active power.
- 1/1 Phase Architecture: Single-phase input and single-phase output match common single-phase critical-power applications.
- Online Power Protection: Provides continuous power conditioning for sensitive electrical and electronic loads.
- เวลาการส่งข้อมูล 0 ms: Maintains output during mains-to-battery transition according to the reference specification.
- Stable Output: Supports 208/220/230VAC output with ±1% voltage regulation.
- Configurable Battery System: Supports 16/18-battery configurations with charging options according to project requirements.
- Communication and Monitoring: RS-232/USB communication with optional SNMP network management.
- การตั้งค่าตามโครงการ: Battery runtime and other system requirements can be reviewed according to the connected load and site conditions.
DAXIN 1/1 10K(L) Key Specifications
| พารามิเตอร์ | 1/1 10K(L) |
|---|---|
| ความจุที่กำหนด | 10kVA / 8kW |
| เฟส | Single Phase Input / Single Phase Output |
| แรงดันไฟฟ้าขาออก | 208 / 220 / 230VAC |
| Voltage Regulation | ±1% |
| ความถี่ในโหมดใช้แบตเตอรี่ | 50 Hz ±0.1 Hz หรือ 60 Hz ±0.1 Hz |
| ค่าครีสต์ | 3:1 Max |
| THD ของสัญญาณออก | ≤3% Linear / ≤5% Non-linear |
| การเปลี่ยนจากระบบไฟฟ้าหลักไปยังแบตเตอรี่ | 0 มิลลิวินาที |
| การเปลี่ยนจากอินเวอร์เตอร์ไปยังระบบบายพาส | 0 มิลลิวินาที |
| ประสิทธิภาพการทำงานในโหมด AC | 88% |
| ประสิทธิภาพของโหมดแบตเตอรี่ | 92% |
| จำนวนแบตเตอรี่ | 16 / 18 pcs |
| Maximum Charging Current | 8A |
| ขนาด | 562 × 250 × 830 mm |
| น้ำหนักสุทธิ | 86 kg |
| อุณหภูมิการทำงาน | 0–50°C |
| ความชื้นสัมพัทธ์ | <95%, Non-Condensing |
| ความสูงในการปฏิบัติการ | <1000m |
| เสียงรบกวน | <58dB @ 1m |
| การสื่อสาร | RS-232 / USB |
| SNMP | ไม่บังคับ |
What Does 1/1 Phase Mean in a UPS?
A 1/1 phase UPS uses single-phase AC power at the input and supplies single-phase AC power at the output.
This configuration is commonly used for critical single-phase loads in server rooms, telecom systems, medical equipment, security systems, financial infrastructure and industrial control applications.
The DAXIN 1/1 10K(L) uses this architecture for applications where both the facility supply and protected equipment require single-phase power.
ข้อมูลผลิตภัณฑ์และข้อมูลทางเทคนิค

การใช้งานทั่วไป
- Server rooms and IT equipment
- Telecom and communication systems
- Industrial control and automation equipment
- Medical and diagnostic equipment
- Banking and financial systems
- ระบบความปลอดภัยและระบบเฝ้าระวัง
- Transportation and infrastructure equipment
- Other critical single-phase electrical loads
How to Select the Right 10kVA Single-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, required backup time, battery configuration, startup or peak load, communication requirements and installation environment.
For the DAXIN 1/1 10K(L), confirm that the site provides the required single-phase input supply and that the protected equipment requires single-phase output.
Provide DAXIN ENERGY with the load list, site voltage, required runtime, battery requirements, communication interfaces and installation conditions to determine the appropriate UPS configuration.
คำถามที่มักถูกถาม
ผลิตภัณฑ์นี้สามารถปรับแต่งให้เหมาะสมกับโครงการเฉพาะได้หรือไม่?
ใช่ครับ การจัดระบบไฟฟ้า เวลาทำงานของแบตเตอรี่ ระบบการสื่อสาร ระบบบายพาส การจัดวางตู้ และอุปกรณ์เสริมของโครงการ สามารถตรวจสอบให้สอดคล้องกับข้อกำหนดของสถานที่ติดตั้งได้.
คะแนนทางเทคนิคทั้งหมดถูกใช้ร่วมกันในทั้งซีรีส์หรือไม่?
ไม่ครับ การจัดอันดับและฟังก์ชันอาจแตกต่างกันไปตามรุ่นและรูปแบบการตั้งค่า โปรดใช้เอกสารทางเทคนิคเฉพาะโครงการเป็นข้อมูลอ้างอิงสุดท้าย.
DAXIN ENERGY สามารถช่วยในการเลือกระบบได้หรือไม่?
ใช่ครับ โปรดให้ข้อมูลเกี่ยวกับรายการโหลด, เฟสและแรงดันไฟฟ้า, เวลาการทำงานที่ต้องการ, เป้าหมายความสำรอง, ข้อกำหนดด้านการสื่อสาร และสภาพแวดล้อมการติดตั้ง.
ขอข้อมูลการตั้งค่าโครงการ
ส่งข้อมูลโหลด แผนผังวงจรแบบเส้นเดียว เวลาสำรองที่จำเป็น และสภาพสถานที่ เพื่อรับข้อเสนอที่ปรับให้เหมาะสมกับความต้องการของคุณสำหรับ UPS หรือแบตเตอรี่.
What is the rated capacity of the DAXIN 1/1 10K(L)?
The reference model is rated at 10kVA / 8kW.
What does 1/1 phase mean?
It means the UPS uses single-phase input and provides single-phase output.
What is the transfer time during a power failure?
The supplied reference specification lists 0ms mains-to-battery transfer.
What output voltage does the UPS support?
The reference configuration supports 208/220/230VAC output with ±1% regulation.
สามารถปรับระยะเวลาการใช้งานของแบตเตอรี่ได้หรือไม่?
Yes. Battery runtime depends on connected load, battery configuration, battery condition and required backup duration.
Does the UPS support remote monitoring?
The reference configuration supports RS-232/USB communication, with optional SNMP network management.









รีวิว