What Is the DAXIN EX3C3 180kVA 3/3 Phase Online UPS?
The DAXIN EX3C3 180kVA is a high-capacity three-phase input and three-phase output online UPS designed to protect mission-critical electrical and electronic loads.
With online double-conversion topology, the UPS continuously supplies connected loads through the inverter, helping provide stable output during utility voltage fluctuations, frequency variations and power interruptions.
The EX3C3 180kVA reference configuration provides 180kVA/180kW rated capacity, 380/400/415VAC three-phase output, 0ms transfer time, greater than 96.5% efficiency and optional SNMP network management.
Typical applications include data centers, industrial facilities, telecom infrastructure, healthcare systems, transportation infrastructure and other facilities requiring high-capacity three-phase power protection.
O que verificar antes de fazer o pedido
- Measured load and expansion allowance
- Required redundancy architecture
- Battery autonomy and room conditions
- Bypass, protection coordination and remote monitoring
Solicitar uma configuração de projeto
Envie à DAXIN ENERGY a lista de cargas, a tensão no local, o tempo de operação necessário, o ambiente de instalação e os requisitos de comunicação e redundância. A configuração final está sujeita à proposta técnica aprovada.
Vídeo adicional sobre o produto UPS de alta frequência da DAXIN
Assista à demonstração do produto para conhecer o formato do no-break, a interface operacional e o posicionamento da aplicação. A configuração elétrica final está sujeita à proposta técnica aprovada.
EX3C3 180kVA Three-Phase Online UPS
The DAXIN ENERGY EX3C3 180kVA online UPS is engineered for large-scale critical power backup applications that require reliable three-phase power, high efficiency and stable system operation. Its double-conversion online topology helps isolate sensitive equipment from grid fluctuation, voltage instability, frequency variation, harmonic interference and unexpected power interruptions.
Principais recursos
High-Reliability Online Double-Conversion Design
- True online double-conversion topology delivers clean sine wave output for critical loads.
- Output frequency tracking, phase locking, voltage regulation and noise filtering reduce the impact of unstable grid power.
- O controle modular avançado com dois processadores aumenta a confiabilidade do sistema e a estabilidade operacional.
- Wide AC input voltage range helps reduce unnecessary battery discharge in poor power environments.
- A função de partida em corrente contínua permite que o no-break inicie diretamente com a bateria quando não houver energia da rede elétrica.
High Efficiency and Grid-Friendly Performance
- Advanced PFC technology keeps the input power factor close to 1.
- O projeto do filtro de harmônicas de entrada ajuda a reduzir a poluição por realimentação na rede elétrica pública.
- Input and output harmonic filters minimize harmonic interference caused by the UPS system.
- High-frequency filtering and synchronization technology improves compatibility with generator power.
Complete Protection Functions
- Proteção contra sobrecarga de saída.
- Proteção contra curto-circuito na saída.
- Proteção contra superaquecimento do inversor.
- Proteção contra aviso de baixa tensão da bateria.
- Proteção contra sobrecarga da bateria.
- Manual maintenance bypass switch supports easier maintenance without interrupting load power.
LCD Display and Intelligent Management
- O visor LCD exibe o status operacional do no-break, os parâmetros do sistema e as informações de alarme em tempo real.
- As interfaces de comunicação RS232/RS485 permitem o monitoramento local e a integração do sistema.
- O adaptador de rede SNMP opcional permite o monitoramento remoto do no-break e o gerenciamento centralizado da energia.
- Compatible with intelligent UPS monitoring software for clear visibility of operating data.
Módulo opcional de monitoramento inteligente da bateria
- Oferece suporte à detecção e ao monitoramento de uma única bateria.
- Oferece funções de alarme para sobretensão, subtensão e diferença de tensão.
- As informações sobre falhas na bateria podem ser exibidas na tela para ajudar os administradores a reagirem rapidamente.
Forte adaptabilidade ambiental
The circuit boards are installed in a fully enclosed structure and treated with conformal coating, improving reliability in harsh environments such as tunnels, plazas, industrial sites and infrastructure facilities.
Aplicações típicas
- Large data centers and server facilities
- Industrial automation and manufacturing plants
- Telecom core networks and communication facilities
- Hospitals and critical healthcare infrastructure
- Transportation, tunnel and traffic-control systems
- Utility and infrastructure facilities
- Commercial buildings and large office campuses
- Other mission-critical three-phase electrical loads
Especificações técnicas
| Modelo | EX3C3-180 kVA |
|---|---|
| Capacidade | 180kVA / 180kW |
| Topologia | UPS de dupla conversão online |
| Fase de entrada | Trifásico + neutro |
| Faixa de tensão de entrada | 110 VCA (F-N) ±31 TP3T com carga de 501 TP3T; 176 VCA (F-N) ±31 TP3T com carga de 1001 TP3T |
| Frequência de entrada | 50 / 60 Hz, seleção automática |
| Fator de potência de entrada | > 0,99 com carga de 100% |
| Tensão de saída | 380 / 400 / 415 VCA, trifásico |
| Regulação da tensão CA | +/-0.3% |
| Frequência de saída | 46-54 Hz ou 56-64 Hz no modo sincronizado; 50 Hz ±0,1 Hz ou 60 Hz ±0,1 Hz no modo de bateria |
| Fator de crista | 3:1 |
| THD de saída | <=1% com carga linear; <=2% com carga não linear |
| Tempo de transferência | 0 ms |
| Eficiência | > 96,51 TP3T no modo CA; > 96,51 TP3T no modo bateria |
| Quantidade de baterias | 32 a 40 unidades, ajustável |
| Corrente de carga | 3-54A +/-10%, pré-ajustado para 3A |
| Dimensões | 1.000 x 600 x 1.200 mm |
| Peso líquido | 265 kg |
| Temperatura de operação | 0 a 40 °C |
| Umidade relativa | < 95%, sem condensação |
| Ruído | < 75 dB a 1 m |
| Comunicação | RS232 / RS485 / USB, SNMP opcional |
FAQ:
What is the rated capacity of the EX3C3 180kVA UPS?
The EX3C3-180kVA reference configuration is rated at 180kVA / 180kW.
Is the EX3C3 180kVA a 3/3 phase UPS?
Yes. It is designed for three-phase input and three-phase output applications.
What is the transfer time?
The reference specification lists 0ms transfer time for continuous online power protection.
What output voltage does the 180kVA UPS support?
A configuração de referência suporta saída trifásica de 380/400/415 VCA.
Does the EX3C3 180kVA support remote monitoring?
Communication options include local interfaces and optional SNMP network management according to the selected configuration.
How should battery runtime be selected?
Battery runtime depends on connected load, battery quantity and capacity, battery condition, temperature and required backup duration. DAXIN ENERGY can review the load and runtime requirements for project configuration.
What Is a 3/3 Phase Online UPS?
A 3/3 phase online UPS uses three-phase AC power at the input and supplies three-phase AC power at the output. This architecture is commonly used for high-capacity critical loads in data centers, industrial facilities, telecom infrastructure, healthcare systems and other large electrical installations.
The DAXIN EX3C3 180kVA is designed for applications requiring high-capacity three-phase input and three-phase output power protection.