UPS Online Rak/Menara 40 kVA | DAXIN HR33

The DAXIN HR33 40KL is a high-frequency online UPS with flexible rack or tower installation for critical power applications. Featuring online double-conversion topology, digital control, LCD monitoring and configurable battery and communication options, it is designed for data centers, server rooms, telecom infrastructure and professional electronic equipment. Final electrical ratings and optional functions depend on the approved HR33 40KL configuration.

Dapatkan Penawaran & Dukungan Teknis

Kirimkan permohonan Anda, jumlah pesanan, dan persyaratan teknisnya. Tim teknik kami akan menanggapi dengan konfigurasi yang sesuai.

Deskripsi

What Is the DAXIN HR33 40KL Rack/Tower Online UPS?

The DAXIN HR33 40KL is a high-frequency online UPS designed to provide conditioned backup power for critical electrical and electronic equipment while supporting flexible rack or tower installation.

Its rack/tower convertible architecture allows the UPS to adapt to different equipment-room layouts, including rack-based IT environments and floor-standing installations.

The HR33 40KL uses online double-conversion operation and supports digital control, LCD monitoring and project-configurable battery, communication, bypass and other system options according to the selected configuration.

Typical applications include data centers, server rooms, telecom facilities, professional electronics and other critical loads requiring reliable online power protection.

What Is a Rack/Tower Convertible UPS?

A rack/tower convertible UPS is designed to support more than one installation orientation. It can be integrated into a compatible equipment rack or configured for tower-style installation, depending on the product design and project requirements.

This flexibility is useful for data centers, server rooms, telecom facilities and other technical environments where equipment layouts may vary between projects.

The DAXIN HR33 40KL uses this flexible installation concept to support different critical-power deployment requirements.

 

Manfaat Utama

    • Rack/Tower Convertible Design: Supports flexible installation in rack-based equipment rooms or tower configurations.
    • Online Double-Conversion Operation: Provides conditioned output power for connected critical loads.
    • High-Frequency UPS Architecture: Designed for professional critical-power applications with a compact installation approach.
    • Digital Control and LCD Monitoring: Supports convenient UPS status monitoring and system operation.
    • Configurable Battery Runtime: Battery configuration can be engineered according to connected load and required backup duration.
    • Communication Options: Monitoring and communication interfaces can be selected according to project requirements.
    • Konfigurasi Berbasis Proyek: EPO, bypass, communications, battery and other optional functions are confirmed according to the selected model and technical proposal.

Tampilan Produk dan Referensi Teknis

Product View for DAXIN HR33 40KL High-Frequency Rack/Tower Convertible UPS.

DAXIN HR33-10KL Online UPS Technical Specifications
Technical specifications for the DAXIN HR33-10KL online UPS.

Aplikasi Umum

  • Pusat data dan ruang server
  • Telecom and communication facilities
  • Network and IT infrastructure
  • Industrial control and automation equipment
  • Sistem keamanan dan pemantauan
  • Professional electronic equipment
  • Critical rack-mounted equipment
  • Floor-mounted critical power applications

How to Select the Right Rack/Tower Online UPS

Select the UPS according to the total connected load, required kVA and kW capacity, input and output phase, operating voltage, required backup time, battery configuration, installation orientation, bypass requirements and communication interfaces.

For rack installations, confirm rack dimensions, available installation space, ventilation and service clearances. For tower installations, confirm floor space, airflow and maintenance access.

Provide DAXIN ENERGY with the load list, site voltage, required runtime, rack or tower installation requirements, communication interfaces and installation environment for project configuration.Selection and Project Planning

Sebelum memesan, pastikan spesifikasi daya yang tepat, fase masukan/keluaran, tegangan, frekuensi, faktor daya, tegangan baterai, waktu operasional, fitur bypass, sistem komunikasi, dimensi, batas lingkungan, dan metode pemasangan sesuai dengan model yang dipilih serta gambar proyek.

Pertanyaan yang Sering Diajukan

Apakah produk ini dapat disesuaikan untuk proyek tertentu?

Ya. Konfigurasi kelistrikan, masa pakai baterai, sistem komunikasi, jalur bypass, tata letak kabinet, dan perlengkapan proyek dapat dievaluasi sesuai dengan persyaratan lokasi.

Apakah semua peringkat teknis berlaku untuk seluruh seri?

Tidak. Peringkat dan fungsi bervariasi tergantung pada model dan konfigurasinya. Gunakan lembar spesifikasi teknis khusus proyek sebagai acuan akhir.

Apakah DAXIN ENERGY dapat membantu dalam pemilihan sistem?

Ya. Sampaikan daftar beban, fase dan tegangan, waktu operasional yang dibutuhkan, target redundansi, persyaratan komunikasi, serta lingkungan pemasangan.

Ajukan Permohonan Konfigurasi Proyek

Kirimkan data beban, diagram satu garis, waktu cadangan yang dibutuhkan, dan kondisi lokasi untuk mendapatkan penawaran UPS atau baterai yang disesuaikan dengan kebutuhan Anda.

Can the HR33 40KL be installed in a rack or as a tower?

The HR33 40KL is described as supporting rack/tower installation flexibility. Final mounting accessories and installation requirements should be confirmed for the selected configuration.

Is the HR33 40KL an online double-conversion UPS?

Yes. The product is described as using online double-conversion operation for conditioned critical-load power protection.

Can battery runtime be customized?

Battery runtime can be engineered according to connected load, required backup duration and the approved battery configuration.

Apakah UPS ini mendukung pemantauan jarak jauh?

Communication and remote-monitoring options depend on the selected configuration and should be confirmed in the approved technical specification.

How should I select the correct UPS configuration?

Provide the load, input/output electrical requirements, backup time, rack or tower installation requirements, communications and site conditions for project selection.

Ulasan

Belum ada ulasan.

Jadilah yang pertama memberikan ulasan “40kVA Rack/Tower Online UPS | DAXIN HR33”

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *