DAXIN 2V 1000Ah AGM UPS Backup Battery | 2V Battery

The DAXIN 2V 1000Ah AGM UPS Backup Battery provides reliable standby power for UPS, telecommunications, emergency lighting, security networks and industrial systems. It features high-quality AGM separators, lead-calcium alloy plates, a sealed leak-resistant ABS enclosure, low self-discharge and an operating temperature range of −20°C to 50°C. Contact DAXIN for battery bank sizing and a project quotation.

Dapatkan Penawaran & Dukungan Teknis

Kirimkan permohonan Anda, jumlah pesanan, dan persyaratan teknisnya. Tim teknik kami akan menanggapi dengan konfigurasi yang sesuai.

Deskripsi

Aplikasi:

  1. Sistem catu daya tanpa gangguan (UPS)
  2. Sistem daya cadangan
  3. Penerangan darurat
  4. Peralatan listrik dan pembangkit listrik
  5. Sistem transportasi
  6. Sistem keamanan dan komunikasi jaringan

Fitur:

  1. Casing ABS anti bocor
  2. Tingkat pelepasan daya sendiri yang rendah dan konstruksi tahan api
  3. Mendukung pemasangan dalam berbagai orientasi
  4. Separator AGM berkualitas tinggi dan pelat paduan timbal-kalsium
  5. Rentang suhu pengoperasian yang luas: −20°C hingga 50°C
DAXIN 2V 1000Ah battery discharge, charging, temperature and cycle life curves
Performance characteristics of the DAXIN 2V 1000Ah battery, including discharge, float charging, temperature, self-discharge and cycle life.
DAXIN 2V AGM UPS battery series specifications, dimensions, capacity and weight
DAXIN 2V AGM battery series specifications, including model, capacity, dimensions, weight and packing information.

What Is the DAXIN 2V 1000Ah AGM UPS Backup Battery?

The DAXIN 2V 1000Ah AGM UPS Backup Battery is a high-capacity stationary battery designed for UPS systems, telecommunications, emergency power, security networks and other standby-power applications. Its 2V cell format supports series-connected battery banks engineered for the required UPS DC bus voltage and backup time.

The battery uses high-quality AGM separators and lead-calcium alloy plates and features a sealed, leak-resistant ABS enclosure with a low self-discharge rate. Final battery quantity, charging parameters and installation arrangement must be confirmed according to the load, required runtime, operating temperature and selected UPS.

Manfaat Utama

  • High-Capacity Standby Power: The 2V 1000Ah rating supports large UPS battery banks and stationary backup-power systems.
  • AGM Technology: High-quality AGM separators support efficient electrolyte retention and maintenance-free operation under specified conditions.
  • Tingkat Pengosongan Diri yang Rendah: Designed to retain stored energy during standby operation and storage.
  • Sealed ABS Enclosure: Leak-resistant construction supports equipment-room and stationary installations when installed according to the approved instructions.
  • Flexible Battery Bank Design: Batteries can be connected in series or parallel according to the required DC voltage, capacity and backup time.
  • Wide Operating Temperature Range: Specified operating range of −20°C to 50°C, subject to approved charging and application conditions.

Aplikasi Umum

  • Uninterruptible power supply systems
  • Sistem catu daya cadangan untuk telekomunikasi
  • Emergency lighting and emergency power
  • Sistem keamanan dan komunikasi jaringan
  • Pembangkit listrik dan gardu induk
  • Sistem kontrol industri dan sistem daya cadangan
  • Transportation infrastructure
  • Stationary energy-storage systems

Gambaran Umum Teknis

Nama ProdukDAXIN 2V 1000Ah AGM UPS Backup Battery
Tegangan Nominal2 V
Kapasitas Terdaftar1000 Ah
Separator TechnologyAGM separator
Plate MaterialLead-calcium alloy
EnclosureSealed, leak-resistant ABS enclosure
Suhu Operasional−20°C to 50°C, subject to approved operating conditions
Aplikasi UmumUPS, telecommunications, emergency power and stationary standby systems

Technical note: Final dimensions, weight, terminal arrangement, charging voltage, discharge performance and service-life expectations must be confirmed using the approved DAXIN model-specific datasheet.

Karakteristik Kinerja Baterai

The following technical reference shows the battery’s discharge characteristics, float-charging behavior, temperature effects on capacity and long-term float life, self-discharge characteristics, and cycle life at different depths of discharge.

DAXIN 2V 1000Ah battery discharge, charging, temperature and cycle life curves

Performance characteristics of the DAXIN 2V 1000Ah battery, including discharge, float charging, temperature, self-discharge and cycle life.

Actual capacity, runtime and service life depend on charging voltage, discharge current, depth of discharge, ambient temperature, storage duration, maintenance and installation conditions.

DAXIN 2V AGM Battery Series Specifications

The DAXIN 2V AGM battery series includes multiple capacity options for different UPS runtime and stationary backup-power requirements. The following table compares model capacity, dimensions, weight and packing information.

DAXIN 2V AGM UPS battery series specifications, dimensions, capacity and weight

DAXIN 2V AGM battery series specifications, including model, capacity, dimensions, weight and packing information.

How to Select the Correct Battery Bank

Battery quantity and configuration must be calculated according to the UPS DC bus voltage, connected load and required backup time. To receive an accurate proposal, provide:

  • UPS brand, model and rated capacity
  • Tegangan bus DC yang diperlukan
  • Beban aktual dalam kW atau kVA
  • Waktu pencadangan yang diperlukan
  • Arus pengisian yang tersedia
  • Suhu lingkungan dan ruang peralatan
  • Persyaratan kabinet baterai, rak, atau ruang pemasangan
  • Redundansi yang diwajibkan dan target masa pakai

Pertanyaan yang Sering Diajukan

What is the DAXIN 2V 1000Ah battery used for?

It is designed for stationary backup-power applications, including UPS battery banks, telecommunications, emergency power, security networks and industrial standby systems.

Berapa banyak baterai 2V yang dibutuhkan untuk sistem UPS?

The quantity depends on the UPS DC bus voltage. Multiple 2V batteries are normally connected in series to achieve the required battery-bank voltage. The final quantity must be confirmed against the approved UPS battery-voltage range.

Can the battery bank be configured for a specific runtime?

Yes. DAXIN can calculate a project-specific battery arrangement based on the actual load, required runtime, DC voltage, discharge conditions and installation environment.

What affects battery capacity and service life?

Battery performance is affected by ambient temperature, charging voltage, discharge current, depth of discharge, discharge frequency, storage conditions and maintenance practices.

Can the battery be installed in different orientations?

Installation orientation must follow the approved DAXIN installation instructions. Do not install or operate the battery in an unapproved orientation.

Are all DAXIN 2V battery models the same size?

No. Capacity, dimensions, weight and terminal arrangements vary by model. Refer to the approved model-specific datasheet before ordering.

Ajukan Permohonan Konfigurasi Bank Baterai

Send your UPS model, DC bus voltage, actual load, required backup time and site conditions to receive a tailored DAXIN battery bank configuration, technical proposal and quotation.

Ulasan

Belum ada ulasan.

Jadilah yang pertama memberikan ulasan “DAXIN 2V 1000Ah AGM UPS Backup Battery | 2V Battery”

Alamat email Anda tidak akan dipublikasikan. Ruas yang wajib ditandai *