Deskripsi
Typical Applications:
- Sistem Catu Daya Tanpa Gangguan (UPS)
- Tenaga cadangan untuk telekomunikasi dan jaringan
- Sistem tenaga darurat dan cadangan
- Sistem keamanan dan komunikasi
- Penerangan darurat
- Sistem transportasi
- Portable and industrial backup-power applications
Fitur:
- Durable ABS construction with leak-proof design
- Low self-discharge rate and flame-retardant properties
- Supports flexible installation in multiple orientations
- Separator AGM berkualitas tinggi dan pelat paduan timbal-kalsium
- Wide operating temperature range: -20°C to 50°C


What Is the DAXIN 6-GFM-250 12V 250Ah AGM VRLA Battery?
The DAXIN 6-GFM-250 is a 12V 250Ah AGM VRLA battery designed for UPS systems, telecom equipment, emergency power, security systems and other standby-power applications.
It uses AGM separators and lead-calcium alloy plates in a sealed ABS enclosure, providing low self-discharge and practical maintenance-free operation for backup-power installations.
Jumlah baterai, konfigurasi seri/paralel, pengaturan pengisian daya, dan kapasitas yang dibutuhkan harus dipilih sesuai dengan tegangan bus DC UPS, beban yang terhubung, dan waktu cadangan yang dibutuhkan.
What Is a 12V 250Ah AGM VRLA Battery?
A 12V 250Ah AGM VRLA battery is a sealed lead-acid battery with a nominal voltage of 12 volts and a rated capacity of 250 amp-hours.
AGM stands for Absorbent Glass Mat, while VRLA means Valve-Regulated Lead-Acid. This battery technology is widely used in UPS, telecom and standby-power systems because it provides sealed construction and low-maintenance operation.
How Long Can a 12V 250Ah Battery Power a UPS?
UPS backup time cannot be determined from the 12V 250Ah rating alone. Actual runtime depends on the connected load, number of batteries, series/parallel configuration, UPS DC bus voltage, inverter efficiency, discharge rate, battery condition and operating temperature.
For accurate battery sizing, provide DAXIN ENERGY with the UPS model, critical load in kW, DC battery voltage and required backup time.
Cara Memilih Baterai UPS
Pilihlah sistem baterai sesuai dengan tegangan bus DC UPS, beban yang terhubung, lama waktu cadangan yang dibutuhkan, laju pengosongan yang diperbolehkan, arus pengisian, ruang pemasangan, suhu pengoperasian, dan kondisi pengoperasian yang diperkirakan.
For multi-battery systems, the required number of 12V batteries and the series/parallel arrangement must match the UPS battery voltage and runtime requirements.
Berikan informasi mengenai model UPS, beban dalam kW, waktu cadangan yang dibutuhkan, dan lingkungan pemasangan kepada DAXIN ENERGY untuk perhitungan kapasitas sistem baterai.
Fitur Utama
- 12V 250Ah Capacity: Dirancang untuk aplikasi UPS dan daya siaga yang membutuhkan cadangan baterai berkapasitas tinggi.
- Teknologi AGM VRLA: Menggunakan pemisah AGM berkualitas tinggi dan pelat paduan timbal-kalsium.
- Sealed ABS Construction: Leak-resistant enclosure supports practical installation in backup-power systems.
- Tingkat Pengosongan Diri yang Rendah: Membantu menjaga kapasitas baterai yang tersedia selama penyimpanan dalam mode siaga.
- Flexible Installation: Supports multiple installation orientations where permitted by the approved battery installation requirements.
- Wide Operating Temperature Range: Designed for operation across -20°C to 50°C according to the supplied product information.
Spesifikasi Utama
| Parameter | DAXIN 6-GFM-250 |
|---|---|
| Jenis Baterai | Baterai AGM VRLA |
| Tegangan Nominal | 12 V |
| Kapasitas Terdaftar | 250Ah |
| Perkiraan Berat | 64.8kg ±3% |
| Tarif per 20 Jam | 253.2Ah @ 10.5V |
| Tarif per 10 Jam | 250Ah @ 10.5V |
| Tarif per 5 Jam | 217.3Ah @ 10.5V |
| Tarif per 1 Jam | 137.5Ah @ 9.6V |
| Panjang | 522mm |
| Lebar | 268mm |
| Tinggi | 220mm |
| Tinggi Total | 225mm |
| Maximum Discharge Current | 3000A (5s) |
| Resistansi Internal | 2.3mΩ at 25°C, fully charged |
| Kapasitas pada 25°C | 100% |
| Kapasitas pada 0°C | 85% |
| Kapasitas pada suhu -15°C | 65% |
| Self-Discharge / Remaining Capacity after 1 Month | 98% |
| After 3 Months | 94% |
| After 6 Months | 85% |
| After 12 Months | 74% |
Pemilihan dan Perencanaan Proyek
Sebelum memesan, pastikan spesifikasi daya yang tepat, fase masukan/keluaran, tegangan, frekuensi, faktor daya, tegangan baterai, waktu operasional, fitur bypass, sistem komunikasi, dimensi, batas lingkungan, dan metode pemasangan sesuai dengan model yang dipilih serta gambar proyek.
Pertanyaan yang Sering Diajukan
Apakah produk ini dapat disesuaikan untuk proyek tertentu?
Ya. Konfigurasi kelistrikan, masa pakai baterai, sistem komunikasi, jalur bypass, tata letak kabinet, dan perlengkapan proyek dapat dievaluasi sesuai dengan persyaratan lokasi.
Apakah semua peringkat teknis berlaku untuk seluruh seri?
Tidak. Peringkat dan fungsi bervariasi tergantung pada model dan konfigurasinya. Gunakan lembar spesifikasi teknis khusus proyek sebagai acuan akhir.
Apakah DAXIN ENERGY dapat membantu dalam pemilihan sistem?
Ya. Sampaikan daftar beban, fase dan tegangan, waktu operasional yang dibutuhkan, target redundansi, persyaratan komunikasi, serta lingkungan pemasangan.
Ajukan Permohonan Konfigurasi Proyek
Kirimkan data beban, diagram satu garis, waktu cadangan yang dibutuhkan, dan kondisi lokasi untuk mendapatkan penawaran UPS atau baterai yang disesuaikan dengan kebutuhan Anda.
What is the DAXIN 6-GFM-250 battery?
The DAXIN 6-GFM-250 is a 12V 250Ah AGM VRLA battery designed for UPS, telecom, emergency and standby-power applications.
Is the 6-GFM-250 an AGM VRLA battery?
Yes. The supplied product information specifies AGM separators and lead-calcium alloy plates in a sealed battery construction.
What is the rated capacity?
The DAXIN 6-GFM-250 is rated at 12V and 250Ah.
What are the battery dimensions?
The supplied specification lists dimensions of 522 × 268 × 220mm, with a total height of 225mm.
How many 12V 250Ah batteries does my UPS need?
The required quantity depends on the UPS DC bus voltage, load, battery configuration and required backup time. Provide the UPS model and runtime requirement for system sizing.
Can DAXIN ENERGY calculate UPS battery runtime?
Yes. Provide the UPS model, connected load in kW, DC battery voltage and required backup time for battery-system selection.