What Is the DAXIN HR33-60KL 60kVA Three Phase Online UPS?
The DAXIN HR33-60KL is a 60kVA/60kW three-phase high-frequency online UPS designed to provide continuous power protection for data centers, telecom facilities, server rooms and other mission-critical electrical loads. It combines online power conversion, high input power factor, low output harmonic distortion and configurable battery support for demanding critical-power applications.
Manfaat Utama
- 60kVA/60kW power capacity for demanding critical-load applications.
- Three-phase input and three-phase output architecture supports data center, telecom and industrial power systems.
- Online power-conversion architecture provides continuous conditioned power for critical equipment.
- Input power factor of ≥0.99 at 100% load supports efficient upstream power utilization.
- AC-mode efficiency up to 95.5% according to the technical specification reference.
- RS-232/USB communications and optional SNMP support local and network-based power management.
- Configurable battery and charging options support project-specific backup-time requirements.
Technical Highlights
DAXIN HR33-60KL Technical Highlights
| Parameter | HR33-60KL |
|---|---|
| Kapasitas Terdaftar | 60 kVA / 60 kW |
| Phase Configuration | Three Phase + Neutral |
| Tegangan Keluaran | 360/380/400/415VAC (Ph-Ph); 208/220/230/240VAC (Ph-N) |
| Pengaturan Tegangan AC | ±1% |
| Faktor Daya Masukan | ≥0,99 pada beban 100% |
| Faktor Puncak | 3:1 (Max.) |
| Efisiensi Mode AC | 95.5% |
| Efisiensi Mode Baterai | 94.5% |
| Dimensi | 797 × 438 × 176 mm (4U) |
| Berat Bersih | 45 kg |
| Tingkat Perlindungan | IP20 |
| Komunikasi | RS-232 / USB |
| Optional Management | SNMP / Web Management |
Tampilan Produk dan Referensi Teknis
Aplikasi Umum
The DAXIN HR33-60KL 60kVA three-phase online UPS is designed for critical-power applications including data centers, telecom facilities, server rooms, network infrastructure, industrial control systems and other mission-critical electrical loads requiring reliable and continuous power protection.
Pemilihan dan Perencanaan Proyek
Before selecting the DAXIN HR33-60KL, confirm the total critical load, input/output voltage, three-phase system requirements, required backup runtime, battery configuration, bypass arrangement, communication interface, redundancy requirements and installation environment. DAXIN ENERGY can review the project load data and electrical requirements to support UPS and battery system selection.
Pertanyaan yang Sering Diajukan
Apakah produk ini dapat disesuaikan untuk proyek tertentu?
Ya. Konfigurasi kelistrikan, masa pakai baterai, sistem komunikasi, jalur bypass, tata letak kabinet, dan perlengkapan proyek dapat dievaluasi sesuai dengan persyaratan lokasi.
Apakah semua peringkat teknis berlaku untuk seluruh seri?
Tidak. Peringkat dan fungsi bervariasi tergantung pada model dan konfigurasinya. Gunakan lembar spesifikasi teknis khusus proyek sebagai acuan akhir.
Apakah DAXIN ENERGY dapat membantu dalam pemilihan sistem?
Ya. Sampaikan daftar beban, fase dan tegangan, waktu operasional yang dibutuhkan, target redundansi, persyaratan komunikasi, serta lingkungan pemasangan.
Ajukan Permohonan Konfigurasi Proyek
Kirimkan data beban, diagram satu garis, waktu cadangan yang dibutuhkan, dan kondisi lokasi untuk mendapatkan penawaran UPS atau baterai yang disesuaikan dengan kebutuhan Anda.
What is the power capacity of the DAXIN HR33-60KL?
The DAXIN HR33-60KL is rated at 60kVA/60kW and is designed for three-phase critical-power applications.
Is the HR33-60KL a three-phase UPS?
Yes. The HR33-60KL uses a three-phase system architecture and is designed for demanding data center, telecom, server-room and other critical-power applications.
What applications are suitable for a 60kVA online UPS?
A 60kVA online UPS can support appropriately sized critical loads in data centers, telecom facilities, server rooms, network infrastructure, industrial control systems and other applications requiring continuous protected power. Final UPS sizing should be based on the actual load, redundancy target and required backup runtime.
Does the HR33-60KL support network monitoring?
The technical specification lists RS-232/USB communication interfaces and optional SNMP support for network-based power management.