Description
Typical Applications:
- Uninterruptible Power Supply (UPS) systems
- Telecom and network backup power
- Emergency and standby power systems
- Security and communication systems
- Emergency lighting
- Transportation systems
- Portable and industrial backup-power applications
Features:
- Durable ABS construction with leak-proof design
- Low self-discharge rate and flame-retardant properties
- Supports flexible installation in multiple orientations
- High-quality AGM separators and lead-calcium alloy plates
- Wide operating temperature range: -20°C to 50°C


What Is the DAXIN 6-GFM-250 12V 250Ah AGM VRLA Battery?
The DAXIN 6-GFM-250 is a 12V 250Ah AGM VRLA battery designed for UPS systems, telecom equipment, emergency power, security systems and other standby-power applications.
It uses AGM separators and lead-calcium alloy plates in a sealed ABS enclosure, providing low self-discharge and practical maintenance-free operation for backup-power installations.
Battery quantity, series/parallel configuration, charging settings and required capacity should be selected according to the UPS DC bus voltage, connected load and required backup runtime.
What Is a 12V 250Ah AGM VRLA Battery?
A 12V 250Ah AGM VRLA battery is a sealed lead-acid battery with a nominal voltage of 12 volts and a rated capacity of 250 amp-hours.
AGM stands for Absorbent Glass Mat, while VRLA means Valve-Regulated Lead-Acid. This battery technology is widely used in UPS, telecom and standby-power systems because it provides sealed construction and low-maintenance operation.
How Long Can a 12V 250Ah Battery Power a UPS?
UPS backup time cannot be determined from the 12V 250Ah rating alone. Actual runtime depends on the connected load, number of batteries, series/parallel configuration, UPS DC bus voltage, inverter efficiency, discharge rate, battery condition and operating temperature.
For accurate battery sizing, provide DAXIN ENERGY with the UPS model, critical load in kW, DC battery voltage and required backup time.
How to Select a UPS Battery
Select the battery system according to the UPS DC bus voltage, connected load, required backup runtime, allowable discharge rate, charging current, installation space, operating temperature and expected service conditions.
For multi-battery systems, the required number of 12V batteries and the series/parallel arrangement must match the UPS battery voltage and runtime requirements.
Provide the UPS model, load in kW, required backup time and installation environment to DAXIN ENERGY for battery-system sizing.
Key Features
- 12V 250Ah Capacity: Designed for UPS and standby-power applications requiring high-capacity battery backup.
- AGM VRLA Technology: Uses high-quality AGM separators and lead-calcium alloy plates.
- Sealed ABS Construction: Leak-resistant enclosure supports practical installation in backup-power systems.
- Low Self-Discharge: Helps preserve available battery capacity during standby storage.
- Flexible Installation: Supports multiple installation orientations where permitted by the approved battery installation requirements.
- Wide Operating Temperature Range: Designed for operation across -20°C to 50°C according to the supplied product information.
Key Specifications
| Parameter | DAXIN 6-GFM-250 |
|---|---|
| Battery Type | AGM VRLA Battery |
| Nominal Voltage | 12V |
| Rated Capacity | 250Ah |
| Approx. Weight | 64.8kg ±3% |
| 20-Hour Rate | 253.2Ah @ 10.5V |
| 10-Hour Rate | 250Ah @ 10.5V |
| 5-Hour Rate | 217.3Ah @ 10.5V |
| 1-Hour Rate | 137.5Ah @ 9.6V |
| Length | 522mm |
| Width | 268mm |
| Height | 220mm |
| Total Height | 225mm |
| Maximum Discharge Current | 3000A (5s) |
| Internal Resistance | 2.3mΩ at 25°C, fully charged |
| Capacity @ 25°C | 100% |
| Capacity @ 0°C | 85% |
| Capacity @ -15°C | 65% |
| Self-Discharge / Remaining Capacity after 1 Month | 98% |
| After 3 Months | 94% |
| After 6 Months | 85% |
| After 12 Months | 74% |
Selection and Project Planning
Confirm the exact power rating, input/output phase, voltage, frequency, power factor, battery voltage, runtime, bypass, communications, dimensions, environmental limits and installation method against the selected model and project drawings before ordering.
Frequently Asked Questions
Can this product be configured for a specific project?
Yes. Electrical configuration, battery runtime, communications, bypass, cabinet arrangement and project accessories can be reviewed against the site requirements.
Are all technical ratings shared across the full series?
No. Ratings and functions vary by model and configuration. Use the project-specific technical sheet as the final reference.
Can DAXIN ENERGY support system selection?
Yes. Provide the load list, phase and voltage, required runtime, redundancy target, communication requirements and installation environment.
Request a Project Configuration
Send the load data, single-line diagram, required backup time and site conditions to receive a tailored UPS or battery proposal.
What is the DAXIN 6-GFM-250 battery?
The DAXIN 6-GFM-250 is a 12V 250Ah AGM VRLA battery designed for UPS, telecom, emergency and standby-power applications.
Is the 6-GFM-250 an AGM VRLA battery?
Yes. The supplied product information specifies AGM separators and lead-calcium alloy plates in a sealed battery construction.
What is the rated capacity?
The DAXIN 6-GFM-250 is rated at 12V and 250Ah.
What are the battery dimensions?
The supplied specification lists dimensions of 522 × 268 × 220mm, with a total height of 225mm.
How many 12V 250Ah batteries does my UPS need?
The required quantity depends on the UPS DC bus voltage, load, battery configuration and required backup time. Provide the UPS model and runtime requirement for system sizing.
Can DAXIN ENERGY calculate UPS battery runtime?
Yes. Provide the UPS model, connected load in kW, DC battery voltage and required backup time for battery-system selection.





Reviews
There are no reviews yet.