What Is the DAXIN RM33 180kVA Modular Online UPS?
The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.
Its modular cabinet architecture integrates power modules, centralized control, protection and service access within a scalable UPS platform, allowing installed capacity and redundancy to be configured according to project requirements.
The RM33 series supports 3 × 380/400/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.
Battery configuration, backup runtime, redundancy architecture, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.
DAXIN RM33-180kVA Key Specifications
| Parameter | Spezifikation |
|---|---|
| Modell | RM33-180kVA |
| UPS Type | Modular Online UPS |
| Phase | Three-Phase Input / Three-Phase Output |
| Cabinet Capacity | 180kW or 120kW configuration |
| Batterietyp | External Battery Pack |
| Battery Cabinet Capacity | 30 kVA / 30 kW |
| Optional Battery Cabinets | Up to 6 |
| Eingangsspannung | 3 × 380/400/415VAC (3PH+N) |
| Eingangsfrequenz | 50/60Hz Auto-Detect |
| Eingangsfrequenzbereich | 40–70Hz |
| Eingangsleistungsfaktor | ≥0.99 @ 100% Load |
| Input Current THDi | <2% @ 100% Load |
| Ausgangsspannung | 3 × 380/400/415VAC (3PH+N) |
| Static Voltage Stability | ≤±0.3% Typical Load |
| Dynamic Voltage Stability | ≤±3% Typical Load |
| Ausgangsfrequenz | 50/60 Hz |
| Frequenzbereich | 46–54Hz or 56–64Hz |
| Ausgangs-THD | ≤1% Linear / ≤2% Non-linear |
| Effizienz | Bis zu 96,51 TP3T |
| Abmessungen | 1100 × 600 × 1475mm |
| Nettogewicht | 195 / 223kg |
| Betriebstemperatur | 0–40 °C |
| Höhe | <1000m at Rated Power |
| Schutzart | IP20 |
| Kommunikation | RS-232 / USB |
| Netzwerkmanagement | Optionales SNMP |
Wichtigste Vorteile
- 180kVA Modular UPS Platform: Designed for scalable three-phase critical-power applications in data centers, telecom and industrial facilities.
- Scalable Modular Architecture: Power-module configuration can be planned according to current load, redundancy requirements and future expansion.
- Three-Phase Power Protection: Supports 3 × 380/400/415VAC three-phase input and output.
- Low Input Harmonic Distortion: Input current THDi below 2% at full load helps reduce upstream electrical impact.
- Hoher Eingangsleistungsfaktor: Input power factor is at least 0.99 at 100% load.
- High Efficiency: System efficiency is specified at up to 96.5%.
- External Battery Configuration: Battery capacity and backup runtime can be engineered according to project requirements.
- Remote Monitoring: RS-232/USB communication is supported, with optional SNMP network management.
What Is a Modular UPS System?
A modular UPS system uses multiple power modules within a common UPS cabinet instead of relying on a single fixed-capacity power stage.
This architecture allows capacity, redundancy and maintenance strategy to be planned according to the critical load, required availability and future expansion.
The DAXIN RM33 series combines modular power architecture, centralized control, external battery configurations and network-management options for scalable critical-power applications.
How Should an 180kVA Modular UPS Be Sized?
An 180kVA modular UPS should be sized according to the actual critical load in kW and kVA, load power factor, required redundancy, expected future expansion and battery autonomy.
Modular system design should also consider the number and rating of installed power modules, bypass architecture, upstream and downstream protection, communication requirements and maintenance strategy.
DAXIN ENERGY can review the load list, single-line diagram, required backup time and redundancy target before confirming the final RM33 system configuration.
Produktansichten und technische Informationen

Typische Anwendungsbereiche
- Rechenzentren und Serverräume
- Telecom core facilities and network infrastructure
- Industrial automation and manufacturing plants
- Financial and banking facilities
- Healthcare and medical infrastructure
- Transportation and public infrastructure
- Enterprise IT facilities
- Other scalable mission-critical power systems
Auswahl und Projektplanung
Bitte überprüfen Sie vor der Bestellung die genauen Angaben zu Nennleistung, Eingangs-/Ausgangsphase, Spannung, Frequenz, Leistungsfaktor, Batteriespannung, Laufzeit, Bypass, Kommunikationsschnittstellen, Abmessungen, Umgebungsbedingungen und Installationsart anhand des ausgewählten Modells und der Projektzeichnungen.
Häufig gestellte Fragen
Kann dieses Produkt für ein bestimmtes Projekt angepasst werden?
Ja. Die elektrische Konfiguration, die Batterielaufzeit, die Kommunikationsfunktionen, der Bypass, die Gehäuseanordnung und das Projektzubehör können anhand der Anforderungen vor Ort überprüft werden.
Gelten alle technischen Bewertungen für die gesamte Serie?
Nein. Die Nennleistungen und Funktionen variieren je nach Modell und Konfiguration. Als maßgebliche Grundlage dient das projektspezifische technische Datenblatt.
Kann DAXIN ENERGY bei der Systemauswahl helfen?
Ja. Bitte geben Sie die Lastliste, die Phase und die Spannung, die erforderliche Laufzeit, das Redundanzziel, die Kommunikationsanforderungen und die Installationsumgebung an.
Projektkonfiguration anfordern
Senden Sie uns die Lastdaten, das Einliniendiagramm, die erforderliche Backup-Zeit und die Standortbedingungen, um ein maßgeschneidertes Angebot für eine USV oder Batterielösung zu erhalten.
What is the DAXIN RM33 180kVA?
The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power applications.
What input and output voltage does it support?
The reference specification lists 3 × 380/400/415VAC three-phase input and output.
What are the input power factor and THDi?
The RM33 reference specification lists an input power factor of at least 0.99 at full load and input current THDi below 2%.
What is the efficiency of the RM33 modular UPS?
The reference specification lists system efficiency up to 96.5%. Actual efficiency depends on load and system configuration.
Does the RM33 support remote monitoring?
Yes. RS-232/USB communication is supported, with optional SNMP network management.
Can the RM33-180kVA system be configured for redundancy?
Yes, modular architecture allows redundancy requirements to be considered during system design. Final module quantity, redundancy architecture and installed capacity should be confirmed in the approved technical proposal.