Description
Power Capacity: 1kVA
Operating Mode: Single-phase input / Single-phase output, True Online Double-conversion.
Applications:
Widely applied across various sectors including government, finance, telecommunications, education, transportation, meteorology, broadcasting, commerce and taxation, healthcare, energy, and utilities.
Product Features:
-
True online double-conversion: Ensures seamless power protection.
-
Microprocessor control: Guarantees high reliability and precision.
-
Input Power Factor Correction (PFC): Optimizes energy efficiency from the grid.
-
High Output Power Factor: Up to 0.9 for better load compatibility.
-
Wide Input Voltage Range (90V – 300V): Ideal for unstable power environments.
-
Frequency Converter Mode: Highly efficient frequency conversion options.
-
Generator Compatible: Works effectively with various generator sets.
-
Advanced Monitoring: Optional SNMP card works seamlessly with USB or RS232 for comprehensive remote management.
-
User-friendly Display: Simple operation and control via the integrated display for real-time UPS status monitoring.
-
ECO Mode: Provides high-efficiency operation for energy saving.
-
Emergency Power Off (EPO): Enhances safety for critical installations.
-
DSP Technology: This series utilizes advanced Digital Signal Processing; includes a built-in maintenance bypass switch (optional).
-
Smart Battery Charger Design: Optimized to extend battery life and maximize performance.
-
Built-in Isolation Transformer (Optional): Provides additional electrical safety and noise suppression.
Technical Specifications
| Item | 11-H1kVA | 11-H2kVA | 11-H3kVA | 11-H6kVA | 11-H10kVA |
|---|---|---|---|---|---|
| Capacity | 1000VA/900W | 2000VA/1800W | 3000VA/2700W | 6000VA/5400W | 10000VA/9000W |
| ### Input | |||||
| Phase | Single-phase grounded | Single-phase grounded | Single-phase grounded | Single-phase grounded | Single-phase grounded |
| Minimum Transfer Voltage | colspan=”3″ | 160VAC/140VAC/120VAC/110VAC ±5% (Ambient temp <35℃; Load ratio: 100%-80%-80%-70%-70%-70%-60%-60%-0) | colspan=”2″ | 50% load: 110VAC ±3%;
100% load: 176VAC ±3% |
|
| Minimum Restore Voltage | colspan=”3″ | 195VAC/175VAC/155VAC/135VAC ±5% (Ambient temp <35℃; Load ratio: 100%-80%-80%-70%-70%-60%-60%-0) | colspan=”2″ | Minimum transfer voltage +10V | |
| Maximum Transfer Voltage | colspan=”3″ | 300VAC ±5% | colspan=”2″ | 300VAC ±3% | |
| Maximum Restore Voltage | colspan=”3″ | 290VAC ±5% | colspan=”2″ | Maximum transfer voltage -10V | |
| Frequency Range | colspan=”3″ | 40Hz ~ 70Hz | colspan=”2″ | 46Hz~54Hz (@50Hz system);
56Hz~64Hz (@60Hz system) |
|
| Power Factor | colspan=”3″ | ≥0.99 @ 220-230-240VAC (input voltage) | colspan=”2″ | N/A | |
| ### Output | |||||
| Output Voltage | colspan=”3″ | 208/220/230/240VAC ±1% | colspan=”2″ | 208/220/230/240VAC ±1% | |
| Frequency Range (Sync Correction) | colspan=”3″ | 47-53Hz or 57-63Hz | colspan=”2″ | 46-54Hz or 56-64Hz | |
| Frequency Range (Battery Mode) | colspan=”3″ | 50±0.25Hz or 60±0.3Hz | colspan=”2″ | 50±0.1Hz or 60±0.1Hz | |
| Crest Factor | colspan=”5″ | 3:1 | |||
| Total Harmonic Distortion (THD) | colspan=”3″ | ≤3% THD (linear load); ≤6% THD (non-linear load) | colspan=”2″ | ≤3% THD (linear load); ≤5% THD (non-linear load) | |
| Overload Capability | colspan=”3″ | Temp<35℃:
105%-110%: UPS auto-restarts in 10s after fault; recovers output within 1s when input normalizes 110%-130%: UPS auto-shuts down after 3 mins; recovers output after 3s when input normalizes >150%: UPS instant shutdown |
colspan=”2″ | 100%~110%: 30 minutes
110%~130%: 5 minutes >130%: 10 seconds |
|
| Transfer Time: Mains to Battery | colspan=”3″ | 0ms | colspan=”2″ | 0ms | |
| Transfer Time: Inverter to Bypass | colspan=”3″ | 4ms (standard condition) | colspan=”2″ | 0ms | |
| Waveform (Battery Mode) | colspan=”3″ | Pure Sine Wave | colspan=”2″ | N/A | |
| ### Efficiency | |||||
| Mains Mode | 88% | 89% | 90% | 92% | 93% |
| Battery Mode | 83% | 87% | 88% | 90% | 91% |
| ### Battery | |||||
| Standard Unit (S) | |||||
| Battery Type | colspan=”3″ | 12V/7Ah | colspan=”2″ | 12V/7Ah | |
| Battery Quantity | 2 | 4 | 6 | 12 | 16 |
| Charging Current | colspan=”3″ | 1.0A | colspan=”2″ | Preset: 1.0A ±10%, Max: 1A/2A | |
| Long-Run Unit (L) | |||||
| Battery Type | colspan=”5″ | 12V/AH (Customized per purchaser requirement) | |||
| Battery Quantity | 3 | 3 | 8 | colspan=”2″ | Model-dependent |
| Charging Current | colspan=”3″ | 1A/2A/4A/6A | colspan=”2″ | 1A/2A/4A/6A (adjustable);
6A only applicable for 16-cell battery pack |
|
| ### Physical Specifications | |||||
| Standard Unit | |||||
| Dimension: D×W×H (mm) | 282×145×220 | 397×145×220 | 421×190×318 | 369×190×688 | 442×190×688 |
| Net Weight (kg) | 9.8 | 17 | 26.2 | 51 | 55 |
| Long-Run Unit | |||||
| Dimension: D×W×H (mm) | 282×145×220 | 397×145×220 | 421×190×318 | 369×190×318 | 442×190×318 |
| Net Weight (kg) | 4.4 | 6.8 | 7.4 | 12 | 15 |
| ### Operating Environment | |||||
| Operating Humidity | colspan=”3″ | 20-90% RH, 0-40℃ (non-condensing) | colspan=”2″ | <95% RH, non-condensing | |
| Noise | colspan=”3″ | <50dB @ 1 meter | <55dB @ 1 meter | <58dB @ 1 meter | |
| Operating Temperature | colspan=”3″ | N/A | colspan=”2″ | 0 ~ 40℃ (Battery life shortened above 25℃ ambient temp) | |
| ### Control & Management | |||||
| Intelligent RS-232/USB | colspan=”5″ | Compatible with Windows 2000/2003/XP/Vista/2008, Windows7/8, Linux & MAC systems | |||
| Optional SNMP Card | colspan=”5″ | Supports SNMP network management & remote monitoring |
-
For 1-3kVA UPS: Output power capacity will be derated to 80% when the UPS is set to CVCF mode (Constant Voltage Constant Frequency) or when the output voltage is set to 208VAC.
-
For 6/10kVA UPS: Output power capacity will be derated to 60% when the UPS is set to CVCF mode, and derated to 90% when the output voltage is set to 208VAC.
-
Parallel Redundancy: The standard models listed above do not support redundant parallel operation.
-
Voltage Compatibility: Output voltage settings of 200/208/220/230/240VAC are only applicable to long-run models.