Onduleur en ligne basse fréquence de 400 kVA | DAXIN 3H3 400K-T

The DAXIN 3H3 400K-T is a 400kVA/360kW low-frequency 3/3 phase double-conversion online UPS designed for large industrial, data center and infrastructure critical-power applications. It supports 380/400/415VAC three-phase operation, >0.99 input power factor, <3% input current THDi, configurable battery technologies and smart-mode efficiency up to 98.5%.

Obtenir un devis et une assistance technique

Envoyez-nous votre demande, les quantités souhaitées et vos spécifications techniques. Notre équipe d'ingénieurs vous proposera une configuration adaptée.

Description

What Is the DAXIN 3H3 400K-T 400kVA Online UPS?

The DAXIN 3H3 400K-T is a 400kVA/360kW low-frequency 3/3 phase double-conversion online UPS designed for large industrial, data center, infrastructure and mission-critical power applications.

Its three-phase input and three-phase output architecture supports facilities operating large three-phase critical loads. The reference configuration supports 380/400/415VAC operation, an input power factor greater than 0.99 and input current THDi below 3%.

The UPS provides 400kVA apparent power and 360kW active power, with static output voltage stability of ±1%, dynamic voltage stability of ±5% within 10ms and a 3:1 crest factor.

Battery technology, bypass configuration, communication interfaces and other project options should be confirmed according to the required backup time, site electrical system and approved DAXIN technical proposal.

Battery Configuration Options

The DAXIN 3H3 400K-T can be engineered with different energy-storage technologies according to project requirements.

  • Valve-regulated sealed lead-acid batteries
  • Nickel-cadmium batteries
  • Supercapacitor systems
  • Lithium battery systems
  • Flywheel energy-storage systems

The final battery technology, capacity and autonomy should be selected according to the connected load, required backup duration, operating environment, lifecycle requirements and project design.

Principaux avantages

  • 400kVA / 360kW Capacity: Designed for large three-phase mission-critical loads.
  • Double-Conversion Online Architecture: Provides continuous conditioned power for critical electrical equipment.
  • 3/3 Phase Configuration: Three-phase input and three-phase output support large industrial and infrastructure electrical systems.
  • Grid-Friendly Input Performance: Input power factor greater than 0.99 and input current THDi below 3% help reduce upstream electrical impact.
  • Sortie stable : Static voltage stability of ±1% and dynamic voltage stability of ±5% within 10ms support sensitive critical loads.
  • Strong Overload Capability: The reference specification supports 110% load for 60 minutes, 125% for 10 minutes and 150% for 1 minute.
  • Flexible Energy Storage: Multiple battery and energy-storage technologies can be evaluated according to project requirements.
  • High-Efficiency Smart Mode: Smart-mode efficiency is specified at up to 98.5%.

Que signifie « 3/3 phases » dans un onduleur ?

Un onduleur triphasé 3/3 utilise une alimentation triphasée en courant alternatif en entrée et fournit une alimentation triphasée en courant alternatif en sortie.

This architecture is commonly used for high-capacity critical loads in data centers, industrial plants, power infrastructure, transportation systems and other facilities operating large three-phase electrical equipment.

The DAXIN 3H3 400K-T provides a 400kVA/360kW three-phase online UPS platform for these large critical-power applications.

What Should Be Considered When Selecting a 400kVA UPS?

A 400kVA UPS should be selected from the actual critical-load profile rather than nominal capacity alone. Review the connected load in both kW and kVA, power factor, peak demand, future expansion and required operating margin.

For large projects, also evaluate battery autonomy, bypass architecture, upstream and downstream protection coordination, generator compatibility, communication requirements, installation space, ventilation, floor loading and maintenance access.

The DAXIN 3H3 400K-T provides 400kVA apparent power and 360kW active power. DAXIN ENERGY can review the load list, single-line diagram and site conditions before final system configuration.

Présentations des produits et documentation technique

DAXIN 3H3 400K-T 400kVA Online UPS Technical Specifications
Technical specifications for the DAXIN 3H3 400K-T 400kVA/360kW three-phase online UPS.
Enclosure and Connection Detail for DAXIN 3H3 400K-T Low-Frequency 3/3 Phase UPS.

Applications typiques

  • Large data centers and mission-critical IT facilities
  • Industrial manufacturing and process-control facilities
  • Power generation and utility infrastructure
  • Telecom core facilities
  • Hospitals and healthcare campuses
  • Transportation, railway and tunnel infrastructure
  • Commercial and public infrastructure
  • Other high-capacity three-phase critical-power systems

Sélection et planification du projet

Avant de passer commande, vérifiez que la puissance nominale exacte, la phase d'entrée/sortie, la tension, la fréquence, le facteur de puissance, la tension de la batterie, l'autonomie, le contournement, les communications, les dimensions, les limites environnementales et la méthode d'installation correspondent bien au modèle sélectionné et aux plans du projet.

Foire aux questions

Ce produit peut-il être configuré pour un projet spécifique ?

Oui. La configuration électrique, l'autonomie de la batterie, les systèmes de communication, le contournement, la disposition des armoires et les accessoires du projet peuvent être examinés en fonction des exigences du site.

Les notes techniques sont-elles toutes communes à l'ensemble de la série ?

Non. Les caractéristiques techniques et les fonctions varient selon le modèle et la configuration. Veuillez vous référer à la fiche technique spécifique au projet comme référence définitive.

DAXIN ENERGY peut-elle vous aider à choisir un système ?

Oui. Veuillez nous fournir la liste des charges, la phase et la tension, la durée de fonctionnement requise, l'objectif de redondance, les exigences en matière de communication et l'environnement d'installation.

Demander une configuration de projet

Envoyez-nous les données de charge, le schéma unifilaire, le temps de secours requis et les conditions sur site afin de recevoir une proposition sur mesure concernant un onduleur ou une batterie.

What is the rated capacity of the DAXIN 3H3 400K-T?

The reference model is rated at 400kVA / 360kW.

Is the 3H3 400K-T a double-conversion online UPS?

Yes. The supplied technical specification classifies the system as a double-conversion online UPS.

What input and output voltage does it support?

The reference configuration specifies 380/400/415VAC three-phase input and 380/400/415VAC three-phase + neutral output.

What is the input power factor and THDi?

The reference specification lists an input power factor greater than 0.99 and input current THDi below 3%.

What battery technologies can be used?

The specification lists sealed lead-acid, nickel-cadmium, supercapacitor, lithium and flywheel options. Final selection depends on the project.

What is the efficiency of the 3H3 400K-T?

Smart-mode efficiency is specified at up to 98.5%. Actual operating efficiency depends on operating mode, load and system configuration.