Batterie de secours DAXIN 2V 1500 Ah pour onduleur | Alimentation de secours

The DAXIN 2V 1500Ah AGM UPS Backup Battery provides reliable standby power for UPS, telecommunications, emergency lighting, security networks and industrial systems. It features a leak-resistant ABS enclosure, low self-discharge, AGM separators, lead-calcium alloy plates and an operating temperature range of −20°C to 50°C. Contact DAXIN for battery bank sizing and project quotations.

Obtenir un devis et une assistance technique

Envoyez-nous votre demande, les quantités souhaitées et vos spécifications techniques. Notre équipe d'ingénieurs vous proposera une configuration adaptée.

Description

Applications :

  1. Uninterruptible power supply (UPS) systems
  2. Standby power systems
  3. Emergency lighting
  4. Power tools and power stations
  5. Transportation systems
  6. Security and network communication systems

Caractéristiques :

  1. Leak-proof ABS enclosure
  2. Low self-discharge rate and flame-retardant construction
  3. Supports installation in multiple orientations
  4. High-quality AGM separators and lead-calcium alloy plates
  5. Wide operating temperature range: −20°C to 50°C
    DAXIN 2V 1500Ah battery discharge, charging, temperature and cycle life characteristics
    Performance curves for the DAXIN 2V 1500Ah battery, including discharge, float charging, temperature effects, self-discharge and cycle life.

    DAXIN 2V UPS backup battery specifications, dimensions, capacity and weight
    DAXIN 2V UPS backup battery model specifications, including capacity, dimensions, weight and carton size.

What Is the DAXIN 2V 1500Ah UPS Backup Battery?

The DAXIN 2V 1500Ah UPS Backup Battery is designed for stationary backup-power applications that require reliable stored energy during a utility outage or power interruption. Typical applications include UPS battery banks, telecommunications equipment, emergency power systems, security systems, network infrastructure and industrial standby-power installations.

The battery can be configured in series and parallel arrangements according to the required DC bus voltage, backup time, load profile and system capacity. The final battery quantity, charging parameters and cabinet or rack arrangement must be confirmed against the selected UPS and project requirements.

DAXIN 2V 1500Ah UPS Backup Battery for stationary and emergency power applications.

Principaux avantages

  • High-Capacity Backup Power: The 2V 1500Ah rating supports high-capacity stationary battery banks and extended backup-time requirements.
  • Flexible Battery Bank Configuration: Multiple batteries can be connected in series or parallel according to the required system voltage and capacity.
  • Multiple Standby Applications: Suitable for UPS systems, telecommunications, emergency power, security equipment and industrial standby-energy systems.
  • Project-Based Selection: Battery quantity and configuration can be engineered according to the load, DC voltage and required backup time.
  • Technical Performance Reference: Discharge, charging, temperature, self-discharge and cycle-life characteristics are available for project evaluation.

Technical Overview

ProductDAXIN UPS Backup Battery
Tension nominale2 V
Capacité nominale1500 Ah
Typical UseUPS, telecom, emergency power and stationary standby systems
Battery Bank ConfigurationSeries or parallel configuration according to project requirements
Final Technical ReferenceApproved DAXIN datasheet and project proposal

Important: Final dimensions, weight, terminal arrangement, charging voltage, discharge performance, operating temperature and service-life expectations must be confirmed using the approved technical datasheet for the supplied model.

Battery Performance Characteristics

The technical performance reference includes discharge characteristics, float-charging behavior, temperature effects on battery capacity, temperature effects on long-term float life, self-discharge characteristics and cycle life at different depths of discharge.

Discharge, charging, temperature, self-discharge and cycle-life characteristics of the DAXIN 2V 1500Ah battery.

Actual battery performance and service life depend on charging settings, discharge depth, ambient temperature, maintenance conditions, installation environment and operating frequency.

Applications typiques

  • Uninterruptible power supply battery banks
  • Telecommunications backup-power systems
  • Data center and network infrastructure
  • Emergency lighting and emergency power systems
  • Systèmes de sécurité et de surveillance
  • Power stations and substations
  • Industrial control and standby-power systems
  • Stationary energy-storage installations

How to Select the Correct Battery Configuration

To determine the required quantity of DAXIN 2V 1500Ah batteries, provide the following project information:

  • UPS model and rated power
  • Required DC bus voltage
  • Actual load in kW or kVA
  • Required backup time
  • Maximum permitted depth of discharge
  • Available charging current
  • Ambient and equipment-room temperature
  • Battery cabinet, rack or installation-space requirements
  • Required redundancy and service-life target

Foire aux questions

What is the DAXIN 2V 1500Ah battery used for?

It is intended for stationary backup-power applications, including UPS battery banks, telecommunications systems, emergency power, security systems and industrial standby installations.

How many 2V batteries are required for a UPS system?

The required quantity depends on the UPS DC bus voltage. For example, a higher-voltage DC battery bank requires multiple 2V batteries connected in series. The final quantity must be confirmed using the UPS manufacturer’s approved battery-voltage range.

Can the battery bank be designed for a specific backup time?

Yes. DAXIN can review the UPS load, DC voltage, required runtime, discharge conditions and installation environment to propose a suitable battery quantity and arrangement.

What affects the service life of the battery?

Battery service life is affected by ambient temperature, charging voltage, discharge depth, discharge frequency, storage duration, maintenance and installation conditions.

Are all 2V battery models the same size and weight?

No. Dimensions, weight, terminal arrangement and performance vary according to capacity and model. Always use the approved model-specific technical datasheet as the final reference.

Can DAXIN supply a complete battery bank proposal?

Yes. Provide the UPS model, load data, DC bus voltage, required backup time, site temperature and installation requirements for project-specific battery selection.

Request a Battery Bank Configuration

Send your UPS model, load in kW or kVA, DC bus voltage, required backup time and site conditions to receive a tailored DAXIN battery bank proposal and quotation.