Onduleur triphasé en ligne DAXIN ENERGY EX3C3 180 kVA

DAXIN ENERGY EX3C3 180kVA three-phase online UPS provides high-efficiency, double-conversion power protection for data centers, industrial facilities, telecom systems, hospitals, transportation infrastructure and mission-critical commercial applications. With wide AC input voltage range, high input power factor, LCD monitoring, RS232 / RS485 communication and optional SNMP management, it delivers clean, stable and continuous power for critical equipment.

Description

EX3C3 180kVA Three-Phase Online UPS

The DAXIN ENERGY EX3C3 180kVA online UPS is engineered for large-scale critical power backup applications that require reliable three-phase power, high efficiency and stable system operation. Its double-conversion online topology helps isolate sensitive equipment from grid fluctuation, voltage instability, frequency variation, harmonic interference and unexpected power interruptions.

Principales caractéristiques

High-Reliability Online Double-Conversion Design

  • True online double-conversion topology delivers clean sine wave output for critical loads.
  • Output frequency tracking, phase locking, voltage regulation and noise filtering reduce the impact of unstable grid power.
  • Le système de commande modulaire avancé à double processeur améliore la fiabilité et la stabilité de fonctionnement du système.
  • Wide AC input voltage range helps reduce unnecessary battery discharge in poor power environments.
  • La fonction de démarrage en courant continu permet à l'onduleur de démarrer directement à partir de la batterie lorsque le réseau électrique est indisponible.

High Efficiency and Grid-Friendly Performance

  • Advanced PFC technology keeps the input power factor close to 1.
  • La conception d'un filtre d'harmoniques d'entrée contribue à réduire la pollution par rétroaction vers le réseau électrique public.
  • Input and output harmonic filters minimize harmonic interference caused by the UPS system.
  • High-frequency filtering and synchronization technology improves compatibility with generator power.

Complete Protection Functions

  • Protection contre les surcharges en sortie.
  • Protection contre les courts-circuits en sortie.
  • Protection contre la surchauffe de l'onduleur.
  • Protection contre les alertes de tension faible de la batterie.
  • Protection contre la surcharge de la batterie.
  • Manual maintenance bypass switch supports easier maintenance without interrupting load power.

LCD Display and Intelligent Management

  • L'écran LCD affiche en temps réel l'état de fonctionnement de l'onduleur, les paramètres du système et les informations relatives aux alarmes.
  • Les interfaces de communication RS232 / RS485 permettent la surveillance locale et l'intégration au système.
  • Une carte réseau SNMP en option permet la surveillance à distance de l'onduleur et la gestion centralisée de l'alimentation.
  • Compatible with intelligent UPS monitoring software for clear visibility of operating data.

Module optionnel de surveillance intelligente de la batterie

  • Prend en charge la détection et la surveillance d'une seule batterie.
  • Offre des fonctions d'alarme en cas de surtension, de sous-tension et de différence de tension.
  • Les informations relatives aux dysfonctionnements de la batterie peuvent s'afficher à l'écran afin d'aider les administrateurs à réagir rapidement.

Grande capacité d'adaptation à l'environnement

The circuit boards are installed in a fully enclosed structure and treated with conformal coating, improving reliability in harsh environments such as tunnels, plazas, industrial sites and infrastructure facilities.

Applications typiques

  • Grands centres de données et salles de serveurs
  • Industrial automation and manufacturing facilities
  • Telecom core equipment rooms
  • Hôpitaux et systèmes de santé
  • Projets d'infrastructures de transport et de tunnels
  • Commercial buildings and large office parks
  • Systèmes d'alimentation de secours

Caractéristiques techniques

Modèle EX3C3-180 kVA
Capacité 180kVA / 180kW
Topologie Onduleur à double conversion en ligne
Phase d'entrée Triphasé + neutre
Plage de tension d'entrée 110 V CA (phase-neutre) ±31 TP3T pour une charge de 501 TP3T ; 176 V CA (phase-neutre) ±31 TP3T pour une charge de 1001 TP3T
Fréquence d'entrée 50 / 60 Hz, sélection automatique
Facteur de puissance d'entrée > 0,99 à une charge de 100%
Tension de sortie 380 / 400 / 415 V CA, triphasé
Régulation de la tension alternative +/-0.3%
Fréquence de sortie 46-54 Hz ou 56-64 Hz en mode synchronisé ; 50 Hz ± 0,1 Hz ou 60 Hz ± 0,1 Hz en mode batterie
Facteur de crête 3:1
THD de sortie <=1% avec une charge linéaire ; <=2% avec une charge non linéaire
Durée du transfert 0 ms
Efficacité > 96,51 TP3T en mode secteur ; > 96,51 TP3T en mode batterie
Nombre de piles 32 à 40 pièces, réglable
Courant de charge 3-54A ±10%, préréglage 3 A
Dimensions 1 000 × 600 × 1 200 mm
Poids net 265 kg
Température de fonctionnement 0 à 40 °C
Humidité relative < 95%, sans condensation
Bruit < 75 dB à 1 m
Communication RS232 / RS485 / USB, SNMP en option
DAXIN ENERGY EX3C3 180kVA three-phase online UPS technical specifications
Technical specifications for DAXIN ENERGY EX3C3 series three-phase online UPS, including the 180kVA model.
Image de partage sur les réseaux sociaux de l'onduleur en ligne DAXIN ENERGY 3H10kVA, destiné aux applications d'alimentation de secours critique et aux onduleurs industriels
Social sharing image for DAXIN ENERGY 3H10kVA online UPS, designed for data centers, telecom power rooms and industrial backup power.

Avis

Il n’y a pas encore d’avis.

Soyez le premier à laisser votre avis sur “DAXIN ENERGY EX3C3 180kVA Three-Phase Online UPS”

Votre adresse e-mail ne sera pas publiée. Les champs obligatoires sont indiqués avec *