Description
What Is the DAXIN 3H3 20kVA 3/3 Phase Online UPS?
The DAXIN 3H3 20kVA is a 20kVA/16kW low-frequency online UPS designed for critical applications requiring three-phase input and three-phase output power protection.
Its 3/3 phase architecture is intended for facilities where both the incoming electrical supply and protected critical loads operate on three-phase power.
The reference configuration supports 380/400/415VAC three-phase input and output, 0ms mains-to-battery transfer and greater than 90% efficiency.
Battery configuration, bypass, communications, redundancy requirements and other project parameters should be confirmed according to the connected load, required backup time and approved DAXIN technical proposal.
Key Benefits
- 20kVA / 16kW Capacity: Designed for medium-capacity critical three-phase loads in industrial and infrastructure applications.
- 3/3 Phase Architecture: Three-phase input and three-phase output support critical three-phase electrical systems.
- Low-Frequency UPS Design: Intended for demanding industrial and infrastructure power-protection applications.
- Online Power Protection: Provides conditioned power for sensitive and mission-critical loads.
- 0ms Mains-to-Battery Transfer: Maintains output during utility-to-battery transition according to the reference specification.
- Configurable Battery System: Battery configuration and runtime can be engineered according to connected load and required backup duration.
- Monitoring and Protection: Display, alarm, protection and communication functions support system operation and maintenance.
- Project-Based Configuration: Parallel, redundancy, bypass and communication capabilities must be confirmed for the selected configuration.
What Does 3/3 Phase Mean in a UPS?
A 3/3 phase UPS uses three-phase AC power at the input and supplies three-phase AC power at the output.
This configuration is commonly used for critical three-phase loads in industrial facilities, server rooms, telecom infrastructure, healthcare systems and transportation applications.
The DAXIN 3H3 20kVA uses this three-phase input and three-phase output architecture for applications requiring reliable 20kVA-class power protection.
20kVA vs 30kVA UPS: Which Capacity Should You Choose?
The DAXIN 3H3 20kVA reference model is rated at 20kVA/16kW, while the 30kVA model provides additional capacity for larger connected loads and future expansion.
The correct UPS capacity should be selected according to actual load in kW and kVA, power factor, startup or peak demand, required operating margin, future expansion and battery runtime.
DAXIN ENERGY can review the load list and project requirements before final model selection.
Product Views and Technical Reference

Typical Applications
- Industrial automation and manufacturing systems
- Server rooms and IT infrastructure
- Telecom and communication facilities
- Power and utility systems
- Hospitals and healthcare equipment
- Transportation and traffic-control infrastructure
- Commercial and public facilities
- Other critical three-phase electrical loads
How to Select a 20kVA Three-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, startup or peak demand, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.
For a 3/3 phase UPS, confirm that both the site electrical supply and protected critical loads require three-phase power.
Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communication interfaces and installation conditions for project configuration.
Frequently Asked Questions
Can this product be configured for a specific project?
Yes. Electrical configuration, battery runtime, communications, bypass, cabinet arrangement and project accessories can be reviewed against the site requirements.
Are all technical ratings shared across the full series?
No. Ratings and functions vary by model and configuration. Use the project-specific technical sheet as the final reference.
Can DAXIN ENERGY support system selection?
Yes. Provide the load list, phase and voltage, required runtime, redundancy target, communication requirements and installation environment.
Request a Project Configuration
Send the load data, single-line diagram, required backup time and site conditions to receive a tailored UPS or battery proposal.
What is the rated capacity of the DAXIN 3H3 20kVA?
The reference model is rated at 20kVA / 16kW.
What does 3/3 phase mean?
It means the UPS uses three-phase input and provides three-phase output.
What is the mains-to-battery transfer time?
The reference specification lists 0ms mains-to-battery transfer.
What output voltage does the UPS support?
The reference configuration supports 380/400/415VAC three-phase output.
Should I choose a 20kVA or 30kVA UPS?
Select according to actual load, power factor, peak demand, operating margin, future expansion and required backup time.
Does the 20kVA UPS support parallel redundancy?
Parallel and redundancy capabilities depend on the selected configuration and must be confirmed against the approved technical specification.








Reviews
There are no reviews yet.