12V 150Ah AGM VRLA UPS Battery | DAXIN 6-GFM-150

DAXIN 6-GFM-150 is a 12V 150Ah AGM VRLA battery designed for UPS, telecom, emergency and standby power applications, featuring sealed construction, low self-discharge, AGM separators and lead-calcium alloy plates.

Get a Quote & Technical Support

Send your application, quantity and technical requirements. Our engineering team will respond with a suitable configuration.

Description

What Is the DAXIN 6-GFM-150 12V 150Ah AGM VRLA Battery?

The DAXIN 6-GFM-150 is a 12V 150Ah AGM VRLA battery designed for UPS systems, telecom equipment, emergency power, security systems and other standby-power applications.

It uses AGM separators and lead-calcium alloy plates in a sealed battery enclosure, providing low self-discharge and practical low-maintenance operation for critical backup-power installations.

Battery quantity, series/parallel configuration, charging settings and required capacity should be selected according to the UPS DC bus voltage, connected load and required backup runtime.

Key Features

  • 12V 150Ah Capacity: Designed for UPS and standby-power applications requiring high-capacity battery backup.
  • AGM VRLA Technology: Uses high-quality AGM separators and lead-calcium alloy plates.
  • Sealed Construction: Leak-resistant battery construction supports practical installation in UPS and backup-power systems.
  • Low Self-Discharge: Helps preserve available battery capacity during standby storage.
  • High Discharge Capability: The supplied specification lists a maximum discharge current of 1880A for 5 seconds.
  • Wide Application Range: Suitable for UPS, telecom, emergency lighting, security and other standby-power applications.

150Ah HTML Technical Specifications

ParameterDAXIN 6-GFM-150
Battery TypeAGM VRLA Battery
Nominal Voltage12V
Rated Capacity150Ah
Approx. Weight41.0kg ±3%
20-Hour Rate156.2Ah @ 10.5V
10-Hour Rate150Ah @ 10.5V
5-Hour Rate133.5Ah @ 10.5V
1-Hour Rate90Ah @ 9.6V
Length484mm
Width170mm
Height241mm
Total Height247mm
Max. Discharge Current1880A (5s)
Internal Resistance3.0mΩ at 25°C, fully charged
Capacity @ 40°C102%
Capacity @ 25°C100%
Capacity @ 0°C85%
Capacity @ -15°C65%
Remaining Capacity after 1 Month98%
Remaining Capacity after 3 Months94%
Remaining Capacity after 6 Months85%
Remaining Capacity after 12 Months74%
DAXIN 6-GFM-250 12V 250Ah Battery Performance Characteristics
Performance characteristics of the DAXIN 6-GFM-250 12V 250Ah battery, including discharge, charging, temperature, self-discharge and cycle-life data.

Product Views and Technical Reference

DAXIN 6-GFM Series 12V AGM VRLA Battery Technical Specifications
Technical specifications for DAXIN 6-GFM Series 12V AGM VRLA batteries from 7Ah to 250Ah.

Product Close-Up for DAXIN 6-GFM-150 12V150AH UPS Backup Battery.

Typical Applications

  • Uninterruptible Power Supply (UPS) systems
  • Telecom and network backup power
  • Emergency and standby power systems
  • Security and communication systems
  • Emergency lighting
  • Transportation systems
  • Industrial backup-power applications

What Is a 12V 150Ah AGM VRLA Battery?

A 12V 150Ah AGM VRLA battery is a sealed lead-acid battery with a nominal voltage of 12 volts and a rated capacity of 150 amp-hours.

AGM stands for Absorbent Glass Mat, while VRLA means Valve-Regulated Lead-Acid. This battery technology is commonly used in UPS, telecom and standby-power systems requiring sealed construction and low-maintenance operation.

150Ah vs 200Ah UPS Battery: Which Should You Choose?

Choose between a 12V 150Ah and 12V 200Ah AGM VRLA battery according to the required UPS backup runtime, DC bus voltage, connected load, installation space and charging capability.

A 200Ah battery provides higher rated capacity for applications requiring longer backup time, while a 150Ah battery offers lower weight and a more compact footprint. Actual UPS runtime depends on load, battery quantity, discharge rate, system efficiency and operating conditions.

How to Select a UPS Battery

Select the battery system according to the UPS DC bus voltage, connected load, required backup runtime, allowable discharge rate, charging current, installation space, operating temperature and expected service conditions.

For multi-battery systems, the number of 12V batteries and their series/parallel arrangement must match the UPS battery voltage and required backup runtime.

Provide the UPS model, load in kW, required backup time and installation environment to DAXIN ENERGY for battery-system sizing.

Selection and Project Planning

Confirm the exact power rating, input/output phase, voltage, frequency, power factor, battery voltage, runtime, bypass, communications, dimensions, environmental limits and installation method against the selected model and project drawings before ordering.

Frequently Asked Questions

What is the DAXIN 6-GFM-150?

The DAXIN 6-GFM-150 is a 12V 150Ah AGM VRLA battery designed for UPS, telecom, emergency and standby-power applications.

What is the rated capacity of the 6-GFM-150?

The DAXIN 6-GFM-150 has a nominal voltage of 12V and a rated capacity of 150Ah.

What are the dimensions of the DAXIN 6-GFM-150?

The supplied specification lists dimensions of 484 × 170 × 241mm, with a total height of 247mm.

How much does the DAXIN 6-GFM-150 weigh?

The supplied specification lists an approximate weight of 41.0kg with a ±3% tolerance.

How many 12V 150Ah batteries does my UPS need?

The required battery quantity depends on the UPS DC bus voltage, connected load, series/parallel configuration and required backup runtime.

How long can a 12V 150Ah battery run a UPS?

UPS runtime depends on the connected load, battery quantity, DC bus voltage, discharge rate, inverter efficiency, battery condition and operating temperature. Provide the UPS model, load in kW and required backup time for battery-system sizing.

Request a UPS Battery Configuration

Send DAXIN ENERGY your UPS model, DC battery voltage, connected load, required backup time, installation environment and available battery space to receive a project-specific battery configuration.

Reviews

There are no reviews yet.

Be the first to review “12V 150Ah AGM VRLA UPS Battery | DAXIN 6-GFM-150”

Your email address will not be published. Required fields are marked *