200kVA Three-Phase Online UPS | DAXIN ENERGY EX3C3

DAXIN ENERGY EX3C3 200kVA three-phase online UPS is designed for large-scale critical power protection in data centers, industrial facilities, telecom networks, hospitals, transportation infrastructure and commercial power backup systems. With online double-conversion topology, high efficiency, wide AC input voltage range, high input power factor, LCD monitoring and optional SNMP management, it delivers clean, stable and continuous power for mission-critical equipment.

Description

EX3C3 200kVA Three-Phase Online UPS

The DAXIN ENERGY EX3C3 200kVA online UPS provides high-capacity three-phase power protection for critical applications that require stable, clean and uninterrupted power. Its online double-conversion architecture helps isolate sensitive equipment from grid fluctuation, voltage instability, frequency variation, harmonic interference, electrical noise and unexpected power interruptions.

Key Features

Reliable Online Double-Conversion Protection

  • True online double-conversion topology provides clean sine wave output for mission-critical loads.
  • Output frequency tracking, phase locking, voltage regulation and noise filtering reduce the impact of unstable utility power.
  • Advanced modular dual-CPU control improves operating reliability, system stability and overall UPS performance.
  • Wide AC input voltage range helps reduce unnecessary battery discharge in areas with unstable grid conditions.
  • DC start function allows the UPS to start directly from battery when utility power is unavailable.

High Efficiency and Grid-Friendly Operation

  • Advanced PFC technology keeps the input power factor close to 1 under different load and utility voltage conditions.
  • Input harmonic filter design helps reduce feedback pollution to the utility grid.
  • Input and output harmonic filters minimize the harmonic impact of the UPS on the power system.
  • High-frequency filtering and synchronization technology improves generator compatibility and reduces generator capacity requirements.

Complete System Protection

  • Output overload protection.
  • Output short-circuit protection.
  • Inverter over-temperature protection.
  • Battery low-voltage warning protection.
  • Battery overcharge protection.
  • Manual maintenance bypass switch supports convenient service while keeping power supplied to the load through bypass.

LCD Display and Smart Monitoring

  • LCD display provides real-time UPS operating status, parameters and alarm information.
  • RS232 / RS485 communication interfaces support local monitoring and system integration.
  • Optional SNMP network adapter enables remote monitoring and centralized UPS management.
  • Compatible UPS monitoring software makes operating data clear and easy to manage.

Optional Intelligent Battery Monitoring Module

  • Supports single battery detection and monitoring.
  • Provides over-voltage, under-voltage and voltage difference alarm functions.
  • Battery fault information can be displayed on the screen to help administrators respond quickly.

Strong Environmental Adaptability

The circuit boards are installed in a fully enclosed structure and treated with conformal coating, improving reliability in harsh environments such as tunnels, plazas, industrial sites, infrastructure facilities and demanding commercial power rooms.

Typical Applications

  • Large data centers and server rooms
  • Industrial manufacturing facilities
  • Telecom core network equipment rooms
  • Hospitals and medical systems
  • Transportation infrastructure and tunnel projects
  • Commercial buildings and office parks
  • Emergency backup power systems
  • Critical power distribution rooms

Technical Specifications

Model EX3C3-200kVA
Capacity 200kVA / 200kW
Topology Online double-conversion UPS
Input Phase Three-phase + neutral
Input Voltage Range 110VAC (Ph-N) +/-3% at 50% load; 176VAC (Ph-N) +/-3% at 100% load
Input Frequency 50 / 60Hz auto selectable
Input Power Factor > 0.99 at 100% load
Output Voltage 380 / 400 / 415VAC, three-phase
AC Voltage Regulation +/-0.3%
Output Frequency 46-54Hz or 56-64Hz in synchronized mode; 50Hz +/-0.1Hz or 60Hz +/-0.1Hz in battery mode
Crest Factor 3:1
Output THD <=1% with linear load; <=2% with nonlinear load
Transfer Time 0ms
Efficiency > 96.5% in AC mode; > 96.5% in battery mode
Battery Quantity 32-40 pcs adjustable
Charging Current 3-54A +/-10%, preset 3A
Dimensions 1000 x 600 x 1200 mm
Net Weight 265 kg
Operating Temperature 0-40 deg C
Relative Humidity < 95%, non-condensing
Noise < 75dB at 1m
Communication RS232 / RS485 / USB, optional SNMP
Category Parameter EX3C3-10kVA

10kVA/9kW

EX3C3-20kVA

20kVA/18kW

EX3C3-30kVA

30kVA/30kW

EX3C3-40kVA

40kVA/40kW

EX3C3-60kVA

60kVA/60kW

EX3C3-80kVA

80kVA/80kW

EX3C3-100kVA

100kVA/100kW

EX3C3-120kVA

120kVA/120kW

EX3C3-180kVA

180kVA/180kW

EX3C3-200kVA

200kVA/200kW

Capacity Rated Capacity 10kVA/9kW 20kVA/18kW 30kVA/30kW 40kVA/40kW 60kVA/60kW 80kVA/80kW 100kVA/100kW 120kVA/120kW 180kVA/180kW 200kVA/200kW
## Input Phase Type Three-phase three-wire Three-phase + Neutral
Voltage Range

Minimum Transfer Voltage

Low Voltage Recovery

High Voltage Recovery

Min transfer voltage +10V

50% load: 110VAC (Ph-N) ±3%;

100% load: 176VAC (Ph-N) ±3%

300VAC (L-N) ±3% @50% load;

276VAC (L-N) ±3% @100% load

Max transfer voltage -10V

Frequency Range 45Hz ~ 55Hz (50Hz system); 56Hz ~ 65Hz (60Hz system), auto switch 50/60Hz
Power Factor ≥0.99 @ 100% load
## Output Output Voltage 3×360/380/400/415VAC (Ph-Ph) 380/400/415VAC (Ph-Ph)
AC Voltage Tolerance ±0.3%
Synchronization Frequency Range 46-54Hz or 56-64Hz
Battery Mode Frequency 50Hz±0.1Hz / 60Hz±0.1Hz
Crest Factor 3.1 (max)
Current THD ≤1% THD (linear load); ≤2% THD (non-linear load)
Transfer Time

Mains to Battery

Inverter to Bypass

0ms

0ms

Overload Capacity 100%~110%: 10min

110%~130%: 1min

>130%: Instant trip

100~110%:60min, 110~125%:10min

125~150%:1min, >150%: Instant trip

105%~110%:60min; 110%~125%:10min

126%~150%:1min; >150%:200ms

## Efficiency Mains Mode >90.5% >91.5% >96.5%
Battery Mode >87% >88% >96.5%
## Battery Battery Strings 16-20 (configurable, default 16) 32-40 (configurable)

Depends on customer requirement

Max Charging Current 4.0A ±10% 1~12A±10% (default 1A)

Max 24A

1~18A±10% (default 1A)

Max 24A

2~24A±10% (default 2A) 2~36A±10% (default 3A) 3~54A±10% (default 3A)
## Physical Dimensions Depth × Width × Height (mm) 592×250×576 815×300×1000 796×360×1010 1000×430×1200 1000×600×1200
Net Weight (kg) 38 40 58 59 87 112 200 200 265 265
## Operating Environment Operating Temperature 0~40°C
Relative Humidity ≤95%, non-condensing
Audible Noise <60dB@1m <65dB@1m <70dB@1m <75dB@1m
Max Altitude <1000m
## Control & Management Intelligent RS232 / USB Supports Windows 2000/2003/XP/Vista/2008, Windows7/8/10, Linux, MAC
Optional SNMP Supports power management & network monitoring via SNMP
DAXIN ENERGY online UPS key features including stable power, wide voltage range, energy saving and easy operation
Key features of DAXIN ENERGY online UPS, including stable power, wide voltage range, energy saving and easy operation.

Reviews

There are no reviews yet.

Be the first to review “200kVA Three-Phase Online UPS | DAXIN ENERGY EX3C3”

Your email address will not be published. Required fields are marked *