Description
EX3C3 200kVA Three-Phase Online UPS
The DAXIN ENERGY EX3C3 200kVA online UPS provides high-capacity three-phase power protection for critical applications that require stable, clean and uninterrupted power. Its online double-conversion architecture helps isolate sensitive equipment from grid fluctuation, voltage instability, frequency variation, harmonic interference, electrical noise and unexpected power interruptions.
Key Features
Reliable Online Double-Conversion Protection
- True online double-conversion topology provides clean sine wave output for mission-critical loads.
- Output frequency tracking, phase locking, voltage regulation and noise filtering reduce the impact of unstable utility power.
- Advanced modular dual-CPU control improves operating reliability, system stability and overall UPS performance.
- Wide AC input voltage range helps reduce unnecessary battery discharge in areas with unstable grid conditions.
- DC start function allows the UPS to start directly from battery when utility power is unavailable.
High Efficiency and Grid-Friendly Operation
- Advanced PFC technology keeps the input power factor close to 1 under different load and utility voltage conditions.
- Input harmonic filter design helps reduce feedback pollution to the utility grid.
- Input and output harmonic filters minimize the harmonic impact of the UPS on the power system.
- High-frequency filtering and synchronization technology improves generator compatibility and reduces generator capacity requirements.
Complete System Protection
- Output overload protection.
- Output short-circuit protection.
- Inverter over-temperature protection.
- Battery low-voltage warning protection.
- Battery overcharge protection.
- Manual maintenance bypass switch supports convenient service while keeping power supplied to the load through bypass.
LCD Display and Smart Monitoring
- LCD display provides real-time UPS operating status, parameters and alarm information.
- RS232 / RS485 communication interfaces support local monitoring and system integration.
- Optional SNMP network adapter enables remote monitoring and centralized UPS management.
- Compatible UPS monitoring software makes operating data clear and easy to manage.
Optional Intelligent Battery Monitoring Module
- Supports single battery detection and monitoring.
- Provides over-voltage, under-voltage and voltage difference alarm functions.
- Battery fault information can be displayed on the screen to help administrators respond quickly.
Strong Environmental Adaptability
The circuit boards are installed in a fully enclosed structure and treated with conformal coating, improving reliability in harsh environments such as tunnels, plazas, industrial sites, infrastructure facilities and demanding commercial power rooms.
Typical Applications
- Large data centers and server rooms
- Industrial manufacturing facilities
- Telecom core network equipment rooms
- Hospitals and medical systems
- Transportation infrastructure and tunnel projects
- Commercial buildings and office parks
- Emergency backup power systems
- Critical power distribution rooms
Technical Specifications
| Model | EX3C3-200kVA |
|---|---|
| Capacity | 200kVA / 200kW |
| Topology | Online double-conversion UPS |
| Input Phase | Three-phase + neutral |
| Input Voltage Range | 110VAC (Ph-N) +/-3% at 50% load; 176VAC (Ph-N) +/-3% at 100% load |
| Input Frequency | 50 / 60Hz auto selectable |
| Input Power Factor | > 0.99 at 100% load |
| Output Voltage | 380 / 400 / 415VAC, three-phase |
| AC Voltage Regulation | +/-0.3% |
| Output Frequency | 46-54Hz or 56-64Hz in synchronized mode; 50Hz +/-0.1Hz or 60Hz +/-0.1Hz in battery mode |
| Crest Factor | 3:1 |
| Output THD | <=1% with linear load; <=2% with nonlinear load |
| Transfer Time | 0ms |
| Efficiency | > 96.5% in AC mode; > 96.5% in battery mode |
| Battery Quantity | 32-40 pcs adjustable |
| Charging Current | 3-54A +/-10%, preset 3A |
| Dimensions | 1000 x 600 x 1200 mm |
| Net Weight | 265 kg |
| Operating Temperature | 0-40 deg C |
| Relative Humidity | < 95%, non-condensing |
| Noise | < 75dB at 1m |
| Communication | RS232 / RS485 / USB, optional SNMP |
| Category | Parameter | EX3C3-10kVA
10kVA/9kW |
EX3C3-20kVA
20kVA/18kW |
EX3C3-30kVA
30kVA/30kW |
EX3C3-40kVA
40kVA/40kW |
EX3C3-60kVA
60kVA/60kW |
EX3C3-80kVA
80kVA/80kW |
EX3C3-100kVA
100kVA/100kW |
EX3C3-120kVA
120kVA/120kW |
EX3C3-180kVA
180kVA/180kW |
EX3C3-200kVA
200kVA/200kW |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Capacity | Rated Capacity | 10kVA/9kW | 20kVA/18kW | 30kVA/30kW | 40kVA/40kW | 60kVA/60kW | 80kVA/80kW | 100kVA/100kW | 120kVA/120kW | 180kVA/180kW | 200kVA/200kW |
| ## Input | Phase Type | Three-phase three-wire | Three-phase + Neutral | ||||||||
| Voltage Range
Minimum Transfer Voltage Low Voltage Recovery High Voltage Recovery |
Min transfer voltage +10V
50% load: 110VAC (Ph-N) ±3%; 100% load: 176VAC (Ph-N) ±3% 300VAC (L-N) ±3% @50% load; 276VAC (L-N) ±3% @100% load Max transfer voltage -10V |
||||||||||
| Frequency Range | 45Hz ~ 55Hz (50Hz system); 56Hz ~ 65Hz (60Hz system), auto switch 50/60Hz | ||||||||||
| Power Factor | ≥0.99 @ 100% load | ||||||||||
| ## Output | Output Voltage | 3×360/380/400/415VAC (Ph-Ph) | 380/400/415VAC (Ph-Ph) | ||||||||
| AC Voltage Tolerance | ±0.3% | ||||||||||
| Synchronization Frequency Range | 46-54Hz or 56-64Hz | ||||||||||
| Battery Mode Frequency | 50Hz±0.1Hz / 60Hz±0.1Hz | ||||||||||
| Crest Factor | 3.1 (max) | ||||||||||
| Current THD | ≤1% THD (linear load); ≤2% THD (non-linear load) | ||||||||||
| Transfer Time
Mains to Battery Inverter to Bypass |
0ms
0ms |
||||||||||
| Overload Capacity | 100%~110%: 10min
110%~130%: 1min >130%: Instant trip |
100~110%:60min, 110~125%:10min
125~150%:1min, >150%: Instant trip |
105%~110%:60min; 110%~125%:10min
126%~150%:1min; >150%:200ms |
||||||||
| ## Efficiency | Mains Mode | >90.5% | >91.5% | >96.5% | |||||||
| Battery Mode | >87% | >88% | >96.5% | ||||||||
| ## Battery | Battery Strings | 16-20 (configurable, default 16) | 32-40 (configurable)
Depends on customer requirement |
||||||||
| Max Charging Current | 4.0A ±10% | 1~12A±10% (default 1A)
Max 24A |
1~18A±10% (default 1A)
Max 24A |
2~24A±10% (default 2A) | 2~36A±10% (default 3A) | 3~54A±10% (default 3A) | |||||
| ## Physical Dimensions | Depth × Width × Height (mm) | 592×250×576 | 815×300×1000 | 796×360×1010 | 1000×430×1200 | 1000×600×1200 | |||||
| Net Weight (kg) | 38 | 40 | 58 | 59 | 87 | 112 | 200 | 200 | 265 | 265 | |
| ## Operating Environment | Operating Temperature | 0~40°C | |||||||||
| Relative Humidity | ≤95%, non-condensing | ||||||||||
| Audible Noise | <60dB@1m | <65dB@1m | <70dB@1m | <75dB@1m | |||||||
| Max Altitude | <1000m | ||||||||||
| ## Control & Management | Intelligent RS232 / USB | Supports Windows 2000/2003/XP/Vista/2008, Windows7/8/10, Linux, MAC | |||||||||
| Optional SNMP | Supports power management & network monitoring via SNMP |









Reviews