60-kVA-Niederfrequenz-Online-USV | DAXIN 3H3

The DAXIN 3H3 60kVA is a 60kVA/48kW low-frequency 3/3 phase online UPS designed for critical applications requiring three-phase input and three-phase output. Featuring online power protection, 0ms mains-to-battery transfer and project-configurable battery, bypass and monitoring options, it is suitable for data centers, industrial facilities, telecom infrastructure, transportation, healthcare and other critical three-phase loads.

Angebot anfordern & technischer Support

Senden Sie uns Ihre Anfrage mit Angaben zur Menge und den technischen Anforderungen. Unser Ingenieurteam wird Ihnen daraufhin eine passende Konfiguration vorschlagen.

Beschreibung

What Is the DAXIN 3H3 60kVA 3/3 Phase Online UPS?

The DAXIN 3H3 60kVA is a 60kVA/48kW low-frequency online UPS designed for critical applications requiring three-phase input and three-phase output power protection.

Its 3/3 phase architecture is intended for facilities where both the incoming electrical supply and protected critical loads operate on three-phase power.

The reference configuration supports 380/400/415VAC three-phase input and output, 0ms mains-to-battery transfer and greater than 90% efficiency.

Battery configuration, bypass, communications, redundancy requirements and other project parameters should be confirmed according to the connected load, required backup time and approved DAXIN technical proposal.

Wichtigste Vorteile

  • 60kVA / 48kW Capacity: Designed for medium-to-high-capacity critical three-phase loads in industrial and infrastructure applications.
  • 3/3 Phase Architecture: Three-phase input and three-phase output support critical three-phase electrical systems.
  • Low-Frequency UPS Design: Intended for demanding industrial and infrastructure critical-power applications.
  • Online Power Protection: Provides conditioned power for sensitive and mission-critical loads.
  • 0 ms Umschaltung von Netzstrom auf Batterie: Maintains output during utility-to-battery transition according to the reference specification.
  • Configurable Battery System: Battery configuration and runtime can be engineered according to connected load and required backup time.
  • Monitoring and Protection: Display, alarm, protection and communication functions support system operation and maintenance.
  • Project-Based Configuration: Parallel, redundancy, bypass and communication capabilities must be confirmed for the selected configuration.

What Does 3/3 Phase Mean in a UPS?

A 3/3 phase UPS uses three-phase AC power at the input and supplies three-phase AC power at the output.

This configuration is commonly used for medium- and high-capacity critical loads in data centers, industrial facilities, telecom infrastructure, healthcare systems and transportation applications.

The DAXIN 3H3 60kVA uses this three-phase input and three-phase output architecture for applications requiring reliable 60kVA-class critical power protection.

What Loads Can a 60kVA UPS Support?

The DAXIN 3H3 60kVA reference model is rated at 60kVA / 48kW. The actual equipment that can be supported depends on the combined active power, power factor, startup or peak demand and required operating margin of the connected loads.

UPS capacity should be selected from measured or calculated load data rather than equipment quantity alone. Future expansion and required battery runtime should also be considered during system design.

Produktansichten und technische Informationen

DAXIN 3H3-60kVA 3/3 Phase Online UPS Technical Specifications
Technical specifications for the DAXIN 3H3-60kVA 3/3 phase online UPS.

Product Close-Up for DAXIN 3H3 60kVA Low-Frequency 3/3 Phase UPS.

Typische Anwendungsbereiche

  • Data centers and server facilities
  • Industrial plants and manufacturing systems
  • Telecom and communication infrastructure
  • Power and utility systems
  • Hospitals and critical healthcare equipment
  • Transportation and tunnel infrastructure
  • Commercial and public infrastructure
  • Other three-phase critical electrical loads

How to Select a 60kVA Three-Phase UPS

Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, startup or peak demand, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.

For a 3/3 phase UPS, confirm that both the site electrical supply and protected critical loads require three-phase power.

Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communication interfaces and installation conditions for project configuration.

Häufig gestellte Fragen

Kann dieses Produkt für ein bestimmtes Projekt angepasst werden?

Ja. Die elektrische Konfiguration, die Batterielaufzeit, die Kommunikationsfunktionen, der Bypass, die Gehäuseanordnung und das Projektzubehör können anhand der Anforderungen vor Ort überprüft werden.

Gelten alle technischen Bewertungen für die gesamte Serie?

Nein. Die Nennleistungen und Funktionen variieren je nach Modell und Konfiguration. Als maßgebliche Grundlage dient das projektspezifische technische Datenblatt.

Kann DAXIN ENERGY bei der Systemauswahl helfen?

Ja. Bitte geben Sie die Lastliste, die Phase und die Spannung, die erforderliche Laufzeit, das Redundanzziel, die Kommunikationsanforderungen und die Installationsumgebung an.

Projektkonfiguration anfordern

Senden Sie uns die Lastdaten, das Einliniendiagramm, die erforderliche Backup-Zeit und die Standortbedingungen, um ein maßgeschneidertes Angebot für eine USV oder Batterielösung zu erhalten.

What is the rated capacity of the DAXIN 3H3 60kVA?

The reference model is rated at 60kVA / 48kW.

What does 3/3 phase mean?

It means the UPS uses three-phase input and provides three-phase output.

What is the mains-to-battery transfer time?

The reference specification lists 0ms mains-to-battery transfer.

What output voltage does the UPS support?

The reference configuration supports 380/400/415VAC three-phase output.

How should a 60kVA UPS be sized?

UPS sizing should consider actual load in kW and kVA, power factor, peak demand, required operating margin, future expansion and backup-time requirements.

Does the 60kVA UPS support parallel redundancy?

Parallel and redundancy capabilities depend on the selected configuration and must be confirmed against the approved technical specification before system design.