What Is the DAXIN 3H3 10kVA 3/3 Phase Online UPS?
The DAXIN 3H3 10kVA is a 10kVA/8kW low-frequency online UPS designed for critical applications requiring three-phase input and three-phase output power protection.
Its 3/3 phase architecture is intended for facilities where both the incoming electrical supply and protected critical loads operate on three-phase power.
The reference configuration supports 380/400/415VAC three-phase input and output, 0ms mains-to-battery transfer and greater than 90% efficiency.
Battery configuration, bypass, communications, redundancy requirements and other project parameters should be confirmed according to the connected load, required backup time and approved DAXIN technical proposal.
المزايا الرئيسية
- 10kVA / 8kW Capacity: Designed for critical three-phase loads requiring a compact lower-capacity 3/3 phase UPS solution.
- 3/3 Phase Architecture: Three-phase input and three-phase output support critical three-phase electrical systems.
- Low-Frequency UPS Design: Intended for demanding industrial and infrastructure power-protection applications.
- Online Power Protection: Provides conditioned power for sensitive and mission-critical loads.
- 0ms Mains-to-Battery Transfer: Maintains output during utility-to-battery transition according to the reference specification.
- Configurable Battery System: Battery configuration and runtime can be engineered according to connected load and required backup duration.
- Monitoring and Protection: Display, alarm, protection and communication functions support system operation and maintenance.
- التكوين القائم على المشاريع: Parallel, redundancy, bypass and communication capabilities must be confirmed for the selected configuration.
What Does 3/3 Phase Mean in a UPS?
A 3/3 phase UPS uses three-phase AC power at the input and supplies three-phase AC power at the output.
This configuration is used where both the facility electrical supply and protected critical equipment operate on three-phase power.
The DAXIN 3H3 10kVA uses this three-phase input and three-phase output architecture for applications requiring 10kVA-class critical power protection.
When Should You Choose a 10kVA Three-Phase UPS?
A 10kVA three-phase UPS may be suitable when the calculated critical load requires three-phase input and output but does not justify the larger footprint or capacity of a 20kVA or 30kVA system.
The DAXIN 3H3 10kVA reference model is rated at 10kVA/8kW. Final sizing should consider actual load in kW and kVA, power factor, startup demand, required operating margin, future expansion and battery runtime.
معلومات عن المنتج والمراجع الفنية
التطبيقات النموذجية
- Industrial automation and control systems
- Small and medium server rooms
- Telecom and communication facilities
- Power and utility control equipment
- Medical and laboratory systems
- Transportation and traffic-control equipment
- Commercial and public infrastructure
- Other critical three-phase electrical loads
How to Select a 10kVA Three-Phase UPS
Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, startup or peak demand, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.
For a 3/3 phase UPS, confirm that both the site electrical supply and protected critical loads require three-phase power.
Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communication interfaces and installation conditions for project configuration.
الأسئلة الشائعة
هل يمكن تخصيص هذا المنتج لمشروع معين؟
نعم. يمكن مراجعة التكوين الكهربائي، ومدة تشغيل البطارية، وأنظمة الاتصالات، ونظام التجاوز، وترتيب الخزانات، وملحقات المشروع، وفقًا لمتطلبات الموقع.
هل يتم تطبيق جميع التصنيفات الفنية على السلسلة بأكملها؟
لا. تختلف القيم التصنيفية والوظائف باختلاف الطراز والتكوين. يرجى الاعتماد على ورقة المواصفات الفنية الخاصة بالمشروع كمرجع نهائي.
هل يمكن لشركة «داكسين إنيرجي» تقديم الدعم في اختيار النظام؟
نعم. يرجى تقديم قائمة الأحمال، وبيانات الطور والجهد الكهربائي، ومدة التشغيل المطلوبة، والهدف المحدد للتكرار، ومتطلبات الاتصال، وبيئة التركيب.
طلب تكوين مشروع
يرجى إرسال بيانات الحمل، والرسم التخطيطي أحادي الخط، ووقت النسخ الاحتياطي المطلوب، وظروف الموقع للحصول على عرض مخصص لجهاز UPS أو البطاريات.
What is the rated capacity of the DAXIN 3H3 10kVA?
The reference model is rated at 10kVA / 8kW.
What does 3/3 phase mean?
It means the UPS uses three-phase input and provides three-phase output.
What is the mains-to-battery transfer time?
The reference specification lists 0ms mains-to-battery transfer.
What output voltage does the UPS support?
The reference configuration supports 380/400/415VAC three-phase output.
Should I choose a 10kVA or 20kVA UPS?
Select according to actual load, power factor, peak demand, required operating margin, future expansion and backup-time requirements.
Does the 10kVA UPS support parallel redundancy?
Parallel and redundancy capabilities depend on the selected configuration and must be confirmed against the approved technical specification.