{"id":3030,"date":"2026-08-02T23:29:54","date_gmt":"2026-08-02T15:29:54","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=3030"},"modified":"2026-08-17T18:28:16","modified_gmt":"2026-08-17T10:28:16","slug":"daxin-rm33-180kva-system-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/vi\/product\/daxin-rm33-180kva-system-ups\/","title":{"rendered":"180kVA Modular Online UPS | DAXIN RM33"},"content":{"rendered":"<h2>What Is the DAXIN RM33 180kVA Modular Online UPS?<\/h2>\n<p>The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.<\/p>\n<p>Its modular cabinet architecture integrates power modules, centralized control, protection and service access within a scalable UPS platform, allowing installed capacity and redundancy to be configured according to project requirements.<\/p>\n<p>The RM33 series supports 3 \u00d7 380\/400\/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.<\/p>\n<p>Battery configuration, backup runtime, redundancy architecture, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.<br \/>\n<strong>DAXIN RM33-180kVA Key Specifications<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Tham s\u1ed1<\/th>\n<th>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>M\u1eabu<\/strong><\/td>\n<td><strong>RM33-180kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Lo\u1ea1i UPS<\/td>\n<td>B\u1ed9 l\u01b0u \u0111i\u1ec7n (UPS) m\u00f4-\u0111un tr\u1ef1c tuy\u1ebfn<\/td>\n<\/tr>\n<tr>\n<td>Giai \u0111o\u1ea1n<\/td>\n<td>\u0110\u1ea7u v\u00e0o ba pha \/ \u0110\u1ea7u ra ba pha<\/td>\n<\/tr>\n<tr>\n<td>Dung t\u00edch t\u1ee7<\/td>\n<td><strong>180kW or 120kW configuration<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Lo\u1ea1i pin<\/td>\n<td>B\u1ed9 pin d\u1ef1 ph\u00f2ng<\/td>\n<\/tr>\n<tr>\n<td>Dung t\u00edch t\u1ee7 pin<\/td>\n<td>30 kVA \/ 30 kW<\/td>\n<\/tr>\n<tr>\n<td>T\u1ee7 ch\u1ee9a pin t\u00f9y ch\u1ecdn<\/td>\n<td>Up to 6<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec7n \u00e1p \u0111\u1ea7u v\u00e0o<\/td>\n<td>3 \u00d7 380\/400\/415 VAC (3 pha + N)<\/td>\n<\/tr>\n<tr>\n<td>T\u1ea7n s\u1ed1 \u0111\u1ea7u v\u00e0o<\/td>\n<td>T\u1ef1 \u0111\u1ed9ng ph\u00e1t hi\u1ec7n 50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>D\u1ea3i t\u1ea7n s\u1ed1 \u0111\u1ea7u v\u00e0o<\/td>\n<td>40\u201370 Hz<\/td>\n<\/tr>\n<tr>\n<td>H\u1ec7 s\u1ed1 c\u00f4ng su\u1ea5t \u0111\u1ea7u v\u00e0o<\/td>\n<td>\u22650,99 @ T\u1ea3i 100%<\/td>\n<\/tr>\n<tr>\n<td>H\u1ec7 s\u1ed1 m\u00e9o h\u00e0i t\u1ed5ng (THDi) c\u1ee7a d\u00f2ng \u0111i\u1ec7n \u0111\u1ea7u v\u00e0o<\/td>\n<td>&lt;2% @ 100% T\u1ea3i<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec7n \u00e1p \u0111\u1ea7u ra<\/td>\n<td>3 \u00d7 380\/400\/415 VAC (3 pha + N)<\/td>\n<\/tr>\n<tr>\n<td>\u0110\u1ed9 \u1ed5n \u0111\u1ecbnh \u0111i\u1ec7n \u00e1p t\u0129nh<\/td>\n<td>\u2264\u00b10,31 TP3T \u2013 T\u1ea3i tr\u1ecdng \u0111i\u1ec3n h\u00ecnh<\/td>\n<\/tr>\n<tr>\n<td>\u1ed4n \u0111\u1ecbnh \u0111i\u1ec7n \u00e1p \u0111\u1ed9ng<\/td>\n<td>\u2264\u00b13% T\u1ea3i tr\u1ecdng ti\u00eau bi\u1ec3u<\/td>\n<\/tr>\n<tr>\n<td>T\u1ea7n s\u1ed1 \u0111\u1ea7u ra<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>D\u1ea3i t\u1ea7n s\u1ed1<\/td>\n<td>46\u201354 Hz ho\u1eb7c 56\u201364 Hz<\/td>\n<\/tr>\n<tr>\n<td>\u0110\u1ed9 m\u00e9o h\u00e0i t\u1ed5ng (THD) \u0111\u1ea7u ra<\/td>\n<td>\u22641% Tuy\u1ebfn t\u00ednh \/ \u22642% Phi tuy\u1ebfn t\u00ednh<\/td>\n<\/tr>\n<tr>\n<td>Hi\u1ec7u qu\u1ea3<\/td>\n<td><strong>L\u00ean \u0111\u1ebfn 96,51 TP3T<\/strong><\/td>\n<\/tr>\n<tr>\n<td>K\u00edch th\u01b0\u1edbc<\/td>\n<td><strong>1100 \u00d7 600 \u00d7 1475mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Tr\u1ecdng l\u01b0\u1ee3ng t\u1ecbnh<\/td>\n<td><strong>195 \/ 223kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Nhi\u1ec7t \u0111\u1ed9 ho\u1ea1t \u0111\u1ed9ng<\/td>\n<td>0\u201340 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u0110\u1ed9 cao<\/td>\n<td>&lt;1.000 m \u1edf c\u00f4ng su\u1ea5t \u0111\u1ecbnh m\u1ee9c<\/td>\n<\/tr>\n<tr>\n<td>C\u1ea5p \u0111\u1ed9 b\u1ea3o v\u1ec7<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Giao ti\u1ebfp<\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td>Qu\u1ea3n l\u00fd m\u1ea1ng<\/td>\n<td>SNMP (t\u00f9y ch\u1ecdn)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2>Nh\u1eefng l\u1ee3i \u00edch ch\u00ednh<\/h2>\n<ul>\n<li><strong>180kVA Modular UPS Platform:<\/strong>\u00a0\u0110\u01b0\u1ee3c thi\u1ebft k\u1ebf cho c\u00e1c \u1ee9ng d\u1ee5ng c\u1ea5p ngu\u1ed3n d\u1ef1 ph\u00f2ng ba pha c\u00f3 kh\u1ea3 n\u0103ng m\u1edf r\u1ed9ng quy m\u00f4 t\u1ea1i c\u00e1c trung t\u00e2m d\u1eef li\u1ec7u, c\u01a1 s\u1edf vi\u1ec5n th\u00f4ng v\u00e0 c\u01a1 s\u1edf c\u00f4ng nghi\u1ec7p.<\/li>\n<li><strong>Ki\u1ebfn tr\u00fac m\u00f4-\u0111un c\u00f3 kh\u1ea3 n\u0103ng m\u1edf r\u1ed9ng:<\/strong>\u00a0Power-module configuration can be planned according to current load, redundancy requirements and future expansion.<\/li>\n<li><strong>B\u1ea3o v\u1ec7 ngu\u1ed3n \u0111i\u1ec7n ba pha:<\/strong>\u00a0H\u1ed7 tr\u1ee3 \u0111\u1ea7u v\u00e0o v\u00e0 \u0111\u1ea7u ra ba pha 3 \u00d7 380\/400\/415 VAC.<\/li>\n<li><strong>\u0110\u1ed9 m\u00e9o h\u00e0i \u0111\u1ea7u v\u00e0o th\u1ea5p:<\/strong>\u00a0Ch\u1ec9 s\u1ed1 THDi c\u1ee7a d\u00f2ng \u0111i\u1ec7n \u0111\u1ea7u v\u00e0o d\u01b0\u1edbi 2% \u1edf \u0111i\u1ec1u ki\u1ec7n t\u1ea3i \u0111\u1ea7y \u0111\u1ee7 gi\u00fap gi\u1ea3m thi\u1ec3u t\u00e1c \u0111\u1ed9ng \u0111i\u1ec7n l\u00ean h\u1ec7 th\u1ed1ng ngu\u1ed3n c\u1ea5p.<\/li>\n<li><strong>H\u1ec7 s\u1ed1 c\u00f4ng su\u1ea5t \u0111\u1ea7u v\u00e0o cao:<\/strong>\u00a0H\u1ec7 s\u1ed1 c\u00f4ng su\u1ea5t \u0111\u1ea7u v\u00e0o ph\u1ea3i \u0111\u1ea1t \u00edt nh\u1ea5t 0,99 khi t\u1ea3i 100%.<\/li>\n<li><strong>Hi\u1ec7u su\u1ea5t cao:<\/strong>\u00a0Hi\u1ec7u su\u1ea5t h\u1ec7 th\u1ed1ng \u0111\u01b0\u1ee3c quy \u0111\u1ecbnh \u1edf m\u1ee9c t\u1ed1i \u0111a l\u00e0 96,51 TP3T.<\/li>\n<li><strong>External Battery Configuration:<\/strong>\u00a0Battery capacity and backup runtime can be engineered according to project requirements.<\/li>\n<li><strong>Gi\u00e1m s\u00e1t t\u1eeb xa:<\/strong>\u00a0H\u1ed7 tr\u1ee3 giao ti\u1ebfp RS-232\/USB, k\u00e8m theo t\u00ednh n\u0103ng qu\u1ea3n l\u00fd m\u1ea1ng SNMP t\u00f9y ch\u1ecdn.<\/li>\n<\/ul>\n<h2>H\u1ec7 th\u1ed1ng UPS m\u00f4-\u0111un l\u00e0 g\u00ec?<\/h2>\n<p>A modular UPS system uses multiple power modules within a common UPS cabinet instead of relying on a single fixed-capacity power stage.<\/p>\n<p>This architecture allows capacity, redundancy and maintenance strategy to be planned according to the critical load, required availability and future expansion.<\/p>\n<p>D\u00f2ng s\u1ea3n ph\u1ea9m DAXIN RM33 k\u1ebft h\u1ee3p ki\u1ebfn tr\u00fac ngu\u1ed3n \u0111i\u1ec7n m\u00f4-\u0111un, \u0111i\u1ec1u khi\u1ec3n t\u1eadp trung, c\u00e1c c\u1ea5u h\u00ecnh pin ngo\u00e0i v\u00e0 c\u00e1c t\u00f9y ch\u1ecdn qu\u1ea3n l\u00fd m\u1ea1ng, nh\u1eb1m \u0111\u00e1p \u1ee9ng c\u00e1c \u1ee9ng d\u1ee5ng ngu\u1ed3n \u0111i\u1ec7n quan tr\u1ecdng c\u00f3 kh\u1ea3 n\u0103ng m\u1edf r\u1ed9ng.<\/p>\n<h2>How Should an 180kVA Modular UPS Be Sized?<\/h2>\n<p>An 180kVA modular UPS should be sized according to the actual critical load in kW and kVA, load power factor, required redundancy, expected future expansion and battery autonomy.<\/p>\n<p>Modular system design should also consider the number and rating of installed power modules, bypass architecture, upstream and downstream protection, communication requirements and maintenance strategy.<\/p>\n<p>DAXIN ENERGY can review the load list, single-line diagram, required backup time and redundancy target before confirming the final RM33 system configuration.<\/p>\n<h2>Th\u00f4ng tin v\u1ec1 s\u1ea3n ph\u1ea9m v\u00e0 t\u00e0i li\u1ec7u tham kh\u1ea3o k\u1ef9 thu\u1eadt<\/h2>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4939\" aria-describedby=\"caption-attachment-4939\" style=\"width: 812px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4939\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp\" alt=\"DAXIN RM33 Modular Online UPS Technical Specifications\" width=\"812\" height=\"1935\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp 812w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-126x300.webp 126w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-430x1024.webp 430w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-768x1830.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-645x1536.webp 645w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-5x12.webp 5w\" sizes=\"auto, (max-width: 812px) 100vw, 812px\" \/><figcaption id=\"caption-attachment-4939\" class=\"wp-caption-text\">Technical specifications for the DAXIN RM33 three-phase modular online UPS series.<\/figcaption><\/figure><figcaption>Product Close-Up for DAXIN RM33-180kVA Modular UPS System Cabinet.<\/figcaption><\/figure>\n<h2>C\u00e1c \u1ee9ng d\u1ee5ng \u0111i\u1ec3n h\u00ecnh<\/h2>\n<ul>\n<li>Trung t\u00e2m d\u1eef li\u1ec7u v\u00e0 ph\u00f2ng m\u00e1y ch\u1ee7<\/li>\n<li>C\u00e1c c\u01a1 s\u1edf h\u1ea1 t\u1ea7ng c\u1ed1t l\u00f5i vi\u1ec5n th\u00f4ng v\u00e0 h\u1ea1 t\u1ea7ng m\u1ea1ng<\/li>\n<li>T\u1ef1 \u0111\u1ed9ng h\u00f3a c\u00f4ng nghi\u1ec7p v\u00e0 c\u00e1c nh\u00e0 m\u00e1y s\u1ea3n xu\u1ea5t<\/li>\n<li>C\u00e1c d\u1ecbch v\u1ee5 t\u00e0i ch\u00ednh v\u00e0 ng\u00e2n h\u00e0ng<\/li>\n<li>Ch\u0103m s\u00f3c s\u1ee9c kh\u1ecfe v\u00e0 c\u01a1 s\u1edf h\u1ea1 t\u1ea7ng y t\u1ebf<\/li>\n<li>Giao th\u00f4ng v\u00e0 c\u01a1 s\u1edf h\u1ea1 t\u1ea7ng c\u00f4ng c\u1ed9ng<\/li>\n<li>C\u01a1 s\u1edf h\u1ea1 t\u1ea7ng CNTT doanh nghi\u1ec7p<\/li>\n<li>C\u00e1c h\u1ec7 th\u1ed1ng c\u1ea5p \u0111i\u1ec7n quan tr\u1ecdng kh\u00e1c c\u00f3 kh\u1ea3 n\u0103ng m\u1edf r\u1ed9ng<\/li>\n<\/ul>\n<h2>L\u1ef1a ch\u1ecdn v\u00e0 l\u1eadp k\u1ebf ho\u1ea1ch d\u1ef1 \u00e1n<\/h2>\n<p>Tr\u01b0\u1edbc khi \u0111\u1eb7t h\u00e0ng, h\u00e3y \u0111\u1ed1i chi\u1ebfu k\u1ef9 l\u01b0\u1ee1ng c\u00e1c th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt ch\u00ednh x\u00e1c v\u1ec1 c\u00f4ng su\u1ea5t \u0111\u1ecbnh m\u1ee9c, pha \u0111\u1ea7u v\u00e0o\/\u0111\u1ea7u ra, \u0111i\u1ec7n \u00e1p, t\u1ea7n s\u1ed1, h\u1ec7 s\u1ed1 c\u00f4ng su\u1ea5t, \u0111i\u1ec7n \u00e1p \u1eafc-quy, th\u1eddi gian ho\u1ea1t \u0111\u1ed9ng, ch\u1ebf \u0111\u1ed9 bypass, h\u1ec7 th\u1ed1ng truy\u1ec1n th\u00f4ng, k\u00edch th\u01b0\u1edbc, gi\u1edbi h\u1ea1n m\u00f4i tr\u01b0\u1eddng v\u00e0 ph\u01b0\u01a1ng ph\u00e1p l\u1eafp \u0111\u1eb7t v\u1edbi m\u1eabu s\u1ea3n ph\u1ea9m \u0111\u00e3 ch\u1ecdn v\u00e0 b\u1ea3n v\u1ebd d\u1ef1 \u00e1n.<\/p>\n<h2>C\u00e1c c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3>S\u1ea3n ph\u1ea9m n\u00e0y c\u00f3 th\u1ec3 \u0111\u01b0\u1ee3c t\u00f9y ch\u1ec9nh cho m\u1ed9t d\u1ef1 \u00e1n c\u1ee5 th\u1ec3 kh\u00f4ng?<\/h3>\n<p>\u0110\u00fang v\u1eady. C\u00f3 th\u1ec3 r\u00e0 so\u00e1t c\u00e1c y\u1ebfu t\u1ed1 nh\u01b0 c\u1ea5u h\u00ecnh \u0111i\u1ec7n, th\u1eddi l\u01b0\u1ee3ng ho\u1ea1t \u0111\u1ed9ng c\u1ee7a pin, h\u1ec7 th\u1ed1ng truy\u1ec1n th\u00f4ng, ch\u1ebf \u0111\u1ed9 bypass, c\u00e1ch b\u1ed1 tr\u00ed t\u1ee7 v\u00e0 c\u00e1c ph\u1ee5 ki\u1ec7n c\u1ee7a d\u1ef1 \u00e1n \u0111\u1ec3 \u0111\u1ea3m b\u1ea3o ph\u00f9 h\u1ee3p v\u1edbi c\u00e1c y\u00eau c\u1ea7u t\u1ea1i hi\u1ec7n tr\u01b0\u1eddng.<\/p>\n<h3>T\u1ea5t c\u1ea3 c\u00e1c ch\u1ec9 s\u1ed1 k\u1ef9 thu\u1eadt c\u00f3 \u0111\u01b0\u1ee3c \u00e1p d\u1ee5ng chung cho to\u00e0n b\u1ed9 lo\u1ea1t phim kh\u00f4ng?<\/h3>\n<p>Kh\u00f4ng. C\u00e1c th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt v\u00e0 ch\u1ee9c n\u0103ng c\u00f3 th\u1ec3 kh\u00e1c nhau t\u00f9y theo t\u1eebng m\u1eabu v\u00e0 c\u1ea5u h\u00ecnh. Vui l\u00f2ng tham kh\u1ea3o b\u1ea3ng th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt d\u00e0nh ri\u00eang cho d\u1ef1 \u00e1n l\u00e0m t\u00e0i li\u1ec7u tham kh\u1ea3o ch\u00ednh th\u1ee9c.<\/p>\n<h3>DAXIN ENERGY c\u00f3 th\u1ec3 h\u1ed7 tr\u1ee3 vi\u1ec7c l\u1ef1a ch\u1ecdn h\u1ec7 th\u1ed1ng kh\u00f4ng?<\/h3>\n<p>V\u00e2ng. Vui l\u00f2ng cung c\u1ea5p danh s\u00e1ch t\u1ea3i, pha v\u00e0 \u0111i\u1ec7n \u00e1p, th\u1eddi gian ho\u1ea1t \u0111\u1ed9ng y\u00eau c\u1ea7u, m\u1ee5c ti\u00eau d\u1ef1 ph\u00f2ng, c\u00e1c y\u00eau c\u1ea7u v\u1ec1 truy\u1ec1n th\u00f4ng v\u00e0 m\u00f4i tr\u01b0\u1eddng l\u1eafp \u0111\u1eb7t.<\/p>\n<h3>Y\u00eau c\u1ea7u c\u1ea5u h\u00ecnh d\u1ef1 \u00e1n<\/h3>\n<p>Vui l\u00f2ng g\u1eedi d\u1eef li\u1ec7u t\u1ea3i, s\u01a1 \u0111\u1ed3 m\u1ea1ch \u0111\u01a1n, th\u1eddi gian d\u1ef1 ph\u00f2ng c\u1ea7n thi\u1ebft v\u00e0 \u0111i\u1ec1u ki\u1ec7n t\u1ea1i hi\u1ec7n tr\u01b0\u1eddng \u0111\u1ec3 nh\u1eadn \u0111\u01b0\u1ee3c \u0111\u1ec1 xu\u1ea5t v\u1ec1 b\u1ed9 l\u01b0u \u0111i\u1ec7n (UPS) ho\u1eb7c \u1eafc-quy ph\u00f9 h\u1ee3p v\u1edbi nhu c\u1ea7u c\u1ee7a qu\u00fd kh\u00e1ch.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"10vliy8\" data-start=\"8494\" data-end=\"8528\">What is the DAXIN RM33 180kVA?<\/h3>\n<p data-start=\"8530\" data-end=\"8649\">The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power applications.<\/p>\n<h3 data-section-id=\"zp921o\" data-start=\"8651\" data-end=\"8701\">Thi\u1ebft b\u1ecb n\u00e0y h\u1ed7 tr\u1ee3 \u0111i\u1ec7n \u00e1p \u0111\u1ea7u v\u00e0o v\u00e0 \u0111\u1ea7u ra l\u00e0 bao nhi\u00eau?<\/h3>\n<p data-start=\"8703\" data-end=\"8789\">Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt tham chi\u1ebfu li\u1ec7t k\u00ea \u0111\u1ea7u v\u00e0o v\u00e0 \u0111\u1ea7u ra ba pha 3 \u00d7 380\/400\/415 VAC.<\/p>\n<h3 data-section-id=\"18hlpeq\" data-start=\"8791\" data-end=\"8836\">H\u1ec7 s\u1ed1 c\u00f4ng su\u1ea5t \u0111\u1ea7u v\u00e0o v\u00e0 THDi l\u00e0 g\u00ec?<\/h3>\n<p data-start=\"8838\" data-end=\"8965\">The RM33 reference specification lists an input power factor of at least 0.99 at full load and input current THDi below 2%.<\/p>\n<h3 data-section-id=\"196h0qa\" data-start=\"8967\" data-end=\"9018\">What is the efficiency of the RM33 modular UPS?<\/h3>\n<p data-start=\"9020\" data-end=\"9148\">The reference specification lists system efficiency up to 96.5%. Actual efficiency depends on load and system configuration.<\/p>\n<h3 data-section-id=\"1xhhnr9\" data-start=\"9150\" data-end=\"9194\">RM33 c\u00f3 h\u1ed7 tr\u1ee3 gi\u00e1m s\u00e1t t\u1eeb xa kh\u00f4ng?<\/h3>\n<p data-start=\"9196\" data-end=\"9282\">\u0110\u00fang v\u1eady. Thi\u1ebft b\u1ecb h\u1ed7 tr\u1ee3 giao ti\u1ebfp RS-232\/USB, k\u00e8m theo t\u00ednh n\u0103ng qu\u1ea3n l\u00fd m\u1ea1ng SNMP t\u00f9y ch\u1ecdn.<\/p>\n<h3 data-section-id=\"610dx3\" data-start=\"9284\" data-end=\"9344\">Can the RM33-180kVA system be configured for redundancy?<\/h3>\n<p data-start=\"9346\" data-end=\"9571\">Yes, modular architecture allows redundancy requirements to be considered during system design. Final module quantity, redundancy architecture and installed capacity should be confirmed in the approved technical proposal.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN RM33 180kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom and industrial facilities. Its modular architecture supports flexible capacity planning, centralized control, external battery configurations and optional SNMP monitoring, with system efficiency up to 96.5%.<\/p>","protected":false},"featured_media":4945,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,100],"product_tag":[],"class_list":["post-3030","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-ups-system-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product\/3030","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/comments?post=3030"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media\/4945"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media?parent=3030"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_brand?post=3030"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_cat?post=3030"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_tag?post=3030"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}