{"id":2950,"date":"2026-08-02T15:22:00","date_gmt":"2026-08-02T15:22:00","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=2950"},"modified":"2026-08-15T22:40:23","modified_gmt":"2026-08-15T14:40:23","slug":"daxin-3h3-40kva-lf33-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/vi\/product\/daxin-3h3-40kva-lf33-ups\/","title":{"rendered":"B\u1ed9 l\u01b0u \u0111i\u1ec7n tr\u1ef1c tuy\u1ebfn t\u1ea7n s\u1ed1 th\u1ea5p 40kVA | DAXIN 3H3"},"content":{"rendered":"<h2>What Is the DAXIN 3H3 40kVA 3\/3 Phase Online UPS?<\/h2>\n<p>The DAXIN 3H3 40kVA is a 40kVA\/32kW low-frequency online UPS designed for critical applications requiring three-phase input and three-phase output power protection.<\/p>\n<p>Its 3\/3 phase architecture is intended for facilities where both the incoming electrical supply and protected critical loads operate on three-phase power.<\/p>\n<p>The reference configuration supports 380\/400\/415VAC three-phase input and output, 0ms mains-to-battery transfer and greater than 90% efficiency.<\/p>\n<p>Battery configuration, bypass, communications, redundancy requirements and other project parameters should be confirmed according to the connected load, required backup time and approved DAXIN technical proposal.<\/p>\n<h2>Nh\u1eefng l\u1ee3i \u00edch ch\u00ednh<\/h2>\n<ul>\n<li><strong>40kVA \/ 32kW Capacity:<\/strong>\u00a0Designed for medium-capacity critical three-phase loads in industrial and infrastructure applications.<\/li>\n<li><strong>3\/3 Phase Architecture:<\/strong>\u00a0Three-phase input and three-phase output support critical three-phase electrical systems.<\/li>\n<li><strong>Low-Frequency UPS Design:<\/strong>\u00a0Intended for demanding industrial and infrastructure power-protection applications.<\/li>\n<li><strong>B\u1ea3o v\u1ec7 ngu\u1ed3n \u0111i\u1ec7n tr\u1ef1c tuy\u1ebfn:<\/strong>\u00a0Provides conditioned power for sensitive and mission-critical loads.<\/li>\n<li><strong>Chuy\u1ec3n \u0111\u1ed5i t\u1eeb ngu\u1ed3n \u0111i\u1ec7n l\u01b0\u1edbi sang pin trong 0 ms:<\/strong>\u00a0Maintains output during utility-to-battery transition according to the reference specification.<\/li>\n<li><strong>H\u1ec7 th\u1ed1ng pin c\u00f3 th\u1ec3 t\u00f9y ch\u1ec9nh:<\/strong>\u00a0Battery configuration and runtime can be engineered according to connected load and required backup duration.<\/li>\n<li><strong>Monitoring and Protection:<\/strong>\u00a0Display, alarm, protection and communication functions support system operation and maintenance.<\/li>\n<li><strong>C\u1ea5u h\u00ecnh theo d\u1ef1 \u00e1n:<\/strong>\u00a0Parallel, redundancy, bypass and communication capabilities must be confirmed for the selected configuration.<\/li>\n<\/ul>\n<h2>What Does 3\/3 Phase Mean in a UPS?<\/h2>\n<p>A 3\/3 phase UPS uses three-phase AC power at the input and supplies three-phase AC power at the output.<\/p>\n<p>This configuration is commonly used for critical three-phase loads in industrial facilities, data centers, telecom infrastructure, healthcare systems and transportation applications.<\/p>\n<p>The DAXIN 3H3 40kVA uses this three-phase input and three-phase output architecture for applications requiring reliable 40kVA-class power protection.<\/p>\n<h2>When Should You Choose a 40kVA UPS?<\/h2>\n<p>A 40kVA UPS may be appropriate when the calculated critical load, operating margin and expected future expansion require capacity above smaller three-phase UPS systems but do not justify a larger 60kVA or 80kVA configuration.<\/p>\n<p>The DAXIN 3H3 40kVA reference model is rated at 40kVA \/ 32kW. Final selection should be based on actual load in kW and kVA, power factor, startup demand, required battery runtime and future capacity requirements.<\/p>\n<h2>\nTh\u00f4ng tin v\u1ec1 s\u1ea3n ph\u1ea9m v\u00e0 t\u00e0i li\u1ec7u tham kh\u1ea3o k\u1ef9 thu\u1eadt<\/h2>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4909\" aria-describedby=\"caption-attachment-4909\" style=\"width: 970px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4909\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS.webp\" alt=\"DAXIN 3H3-60kVA 3\/3 Phase Online UPS Technical Specifications\" width=\"970\" height=\"914\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS.webp 970w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS-300x283.webp 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS-768x724.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS-13x12.webp 13w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" \/><figcaption id=\"caption-attachment-4909\" class=\"wp-caption-text\">Technical specifications for the DAXIN 3H3-60kVA 3\/3 phase online UPS.<\/figcaption><\/figure><\/figure>\n<figure class=\"wp-block-image size-full\"><figcaption>Product Close-Up for DAXIN 3H3 40kVA Low-Frequency 3\/3 Phase UPS.<\/figcaption><\/figure>\n<h2>C\u00e1c \u1ee9ng d\u1ee5ng \u0111i\u1ec3n h\u00ecnh<\/h2>\n<ul>\n<li>Industrial plants and automation systems<\/li>\n<li>Data centers and server facilities<\/li>\n<li>Telecom and communication infrastructure<\/li>\n<li>Power and utility systems<\/li>\n<li>Hospitals and healthcare equipment<\/li>\n<li>Transportation and tunnel infrastructure<\/li>\n<li>Commercial and public facilities<\/li>\n<li>Other three-phase critical electrical loads<\/li>\n<\/ul>\n<h2>How to Select a 40kVA Three-Phase UPS<\/h2>\n<p>Select the UPS according to the actual connected load in kW and kVA, input and output voltage, power factor, startup or peak demand, required backup time, battery configuration, bypass requirements, redundancy architecture, communication interfaces and installation environment.<\/p>\n<p>For a 3\/3 phase UPS, confirm that both the site electrical supply and protected critical loads require three-phase power.<\/p>\n<p>Provide DAXIN ENERGY with the load list, single-line diagram, site voltage, required runtime, redundancy requirements, communication interfaces and installation conditions for project configuration.<\/p>\n<h2>C\u00e1c c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3>S\u1ea3n ph\u1ea9m n\u00e0y c\u00f3 th\u1ec3 \u0111\u01b0\u1ee3c t\u00f9y ch\u1ec9nh cho m\u1ed9t d\u1ef1 \u00e1n c\u1ee5 th\u1ec3 kh\u00f4ng?<\/h3>\n<p>\u0110\u00fang v\u1eady. C\u00f3 th\u1ec3 r\u00e0 so\u00e1t c\u00e1c y\u1ebfu t\u1ed1 nh\u01b0 c\u1ea5u h\u00ecnh \u0111i\u1ec7n, th\u1eddi l\u01b0\u1ee3ng ho\u1ea1t \u0111\u1ed9ng c\u1ee7a pin, h\u1ec7 th\u1ed1ng truy\u1ec1n th\u00f4ng, ch\u1ebf \u0111\u1ed9 bypass, c\u00e1ch b\u1ed1 tr\u00ed t\u1ee7 v\u00e0 c\u00e1c ph\u1ee5 ki\u1ec7n c\u1ee7a d\u1ef1 \u00e1n \u0111\u1ec3 \u0111\u1ea3m b\u1ea3o ph\u00f9 h\u1ee3p v\u1edbi c\u00e1c y\u00eau c\u1ea7u t\u1ea1i hi\u1ec7n tr\u01b0\u1eddng.<\/p>\n<h3>T\u1ea5t c\u1ea3 c\u00e1c ch\u1ec9 s\u1ed1 k\u1ef9 thu\u1eadt c\u00f3 \u0111\u01b0\u1ee3c \u00e1p d\u1ee5ng chung cho to\u00e0n b\u1ed9 lo\u1ea1t phim kh\u00f4ng?<\/h3>\n<p>Kh\u00f4ng. C\u00e1c th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt v\u00e0 ch\u1ee9c n\u0103ng c\u00f3 th\u1ec3 kh\u00e1c nhau t\u00f9y theo t\u1eebng m\u1eabu v\u00e0 c\u1ea5u h\u00ecnh. Vui l\u00f2ng tham kh\u1ea3o b\u1ea3ng th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt d\u00e0nh ri\u00eang cho d\u1ef1 \u00e1n l\u00e0m t\u00e0i li\u1ec7u tham kh\u1ea3o ch\u00ednh th\u1ee9c.<\/p>\n<h3>DAXIN ENERGY c\u00f3 th\u1ec3 h\u1ed7 tr\u1ee3 vi\u1ec7c l\u1ef1a ch\u1ecdn h\u1ec7 th\u1ed1ng kh\u00f4ng?<\/h3>\n<p>V\u00e2ng. Vui l\u00f2ng cung c\u1ea5p danh s\u00e1ch t\u1ea3i, pha v\u00e0 \u0111i\u1ec7n \u00e1p, th\u1eddi gian ho\u1ea1t \u0111\u1ed9ng y\u00eau c\u1ea7u, m\u1ee5c ti\u00eau d\u1ef1 ph\u00f2ng, c\u00e1c y\u00eau c\u1ea7u v\u1ec1 truy\u1ec1n th\u00f4ng v\u00e0 m\u00f4i tr\u01b0\u1eddng l\u1eafp \u0111\u1eb7t.<\/p>\n<h2>Y\u00eau c\u1ea7u c\u1ea5u h\u00ecnh d\u1ef1 \u00e1n<\/h2>\n<p>Vui l\u00f2ng g\u1eedi d\u1eef li\u1ec7u t\u1ea3i, s\u01a1 \u0111\u1ed3 m\u1ea1ch \u0111\u01a1n, th\u1eddi gian d\u1ef1 ph\u00f2ng c\u1ea7n thi\u1ebft v\u00e0 \u0111i\u1ec1u ki\u1ec7n t\u1ea1i hi\u1ec7n tr\u01b0\u1eddng \u0111\u1ec3 nh\u1eadn \u0111\u01b0\u1ee3c \u0111\u1ec1 xu\u1ea5t v\u1ec1 b\u1ed9 l\u01b0u \u0111i\u1ec7n (UPS) ho\u1eb7c \u1eafc-quy ph\u00f9 h\u1ee3p v\u1edbi nhu c\u1ea7u c\u1ee7a qu\u00fd kh\u00e1ch.<\/p>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"7445\" data-end=\"7547\"><strong data-start=\"7445\" data-end=\"7499\">What is the rated capacity of the DAXIN 3H3 40kVA?<\/strong><br data-start=\"7499\" data-end=\"7502\" \/>The reference model is rated at 40kVA \/ 32kW.<\/p>\n<p data-start=\"7549\" data-end=\"7653\"><strong data-start=\"7549\" data-end=\"7578\">What does 3\/3 phase mean?<\/strong><br data-start=\"7578\" data-end=\"7581\" \/>It means the UPS uses three-phase input and provides three-phase output.<\/p>\n<p data-start=\"7655\" data-end=\"7769\"><strong data-start=\"7655\" data-end=\"7702\">What is the mains-to-battery transfer time?<\/strong><br data-start=\"7702\" data-end=\"7705\" \/>The reference specification lists 0ms mains-to-battery transfer.<\/p>\n<p data-start=\"7771\" data-end=\"7890\"><strong data-start=\"7771\" data-end=\"7816\">UPS h\u1ed7 tr\u1ee3 \u0111i\u1ec7n \u00e1p \u0111\u1ea7u ra l\u00e0 bao nhi\u00eau?<\/strong><br data-start=\"7816\" data-end=\"7819\" \/>C\u1ea5u h\u00ecnh tham chi\u1ebfu h\u1ed7 tr\u1ee3 \u0111\u1ea7u ra ba pha 380\/400\/415 VAC.<\/p>\n<p data-start=\"7892\" data-end=\"8072\"><strong data-start=\"7892\" data-end=\"7928\">How should a 40kVA UPS be sized?<\/strong><br data-start=\"7928\" data-end=\"7931\" \/>UPS sizing should consider actual load in kW and kVA, power factor, peak demand, future expansion, operating margin and required backup time.<\/p>\n<p data-start=\"8074\" data-end=\"8269\"><strong data-start=\"8074\" data-end=\"8125\">Does the 40kVA UPS support parallel redundancy?<\/strong><br data-start=\"8125\" data-end=\"8128\" \/>Parallel and redundancy capabilities depend on the selected configuration and must be confirmed against the approved technical specification.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN 3H3 40kVA is a 40kVA\/32kW low-frequency 3\/3 phase online UPS designed for critical applications requiring three-phase input and three-phase output. Featuring online power protection, 0ms mains-to-battery transfer and project-configurable battery, bypass and monitoring options, it is suitable for industrial facilities, data centers, telecom infrastructure, transportation, healthcare and other critical three-phase loads.<\/p>","protected":false},"featured_media":4908,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[109,99,97],"product_tag":[],"class_list":["post-2950","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-low-frequency-3-3-phase-ups","product_cat-low-frequency-ups","product_cat-ups-solutions","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product\/2950","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/comments?post=2950"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media\/4908"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media?parent=2950"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_brand?post=2950"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_cat?post=2950"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_tag?post=2950"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}