{"id":2908,"date":"2026-08-02T15:16:54","date_gmt":"2026-08-02T15:16:54","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=2908"},"modified":"2026-08-15T16:40:16","modified_gmt":"2026-08-15T08:40:16","slug":"daxin-1-1-6k-l-lf11-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/vi\/product\/daxin-1-1-6k-l-lf11-ups\/","title":{"rendered":"B\u1ed9 l\u01b0u \u0111i\u1ec7n tr\u1ef1c tuy\u1ebfn t\u1ea7n s\u1ed1 th\u1ea5p 6kVA | DAXIN 1\/1 6K(L)"},"content":{"rendered":"<h2>What Is the DAXIN 1\/1 6K(L) 6kVA Online UPS?<\/h2>\n<p>The DAXIN 1\/1 6K(L) is a 6kVA\/4.8kW online UPS designed for critical applications requiring single-phase input and single-phase output power protection.<\/p>\n<p>Its 1\/1 phase architecture matches facilities where both the incoming utility supply and protected critical loads operate on single-phase power.<\/p>\n<p>The reference configuration provides 208\/220\/230VAC output, \u00b11% voltage regulation, 0ms mains-to-battery transfer, 88% AC-mode efficiency and 92% battery-mode efficiency.<\/p>\n<p>The UPS supports configurable 16\/18-battery operation, RS-232\/USB communication and optional SNMP network management. Battery configuration, runtime and project options should be selected according to the connected load and required backup duration.<\/p>\n<p><strong>DAXIN 1\/1 6K(L) Key Specifications<br \/>\n<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>Tham s\u1ed1<\/th>\n<th>1\/1 6K(L)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>C\u00f4ng su\u1ea5t \u0111\u1ecbnh m\u1ee9c<\/strong><\/td>\n<td><strong>6kVA \/ 4.8kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Giai \u0111o\u1ea1n<\/td>\n<td>Single-Phase Input \/ Single-Phase Output<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec7n \u00e1p \u0111\u1ea7u ra<\/td>\n<td>208 \/ 220 \/ 230VAC<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec1u ch\u1ec9nh \u0111i\u1ec7n \u00e1p<\/td>\n<td>\u00b11%<\/td>\n<\/tr>\n<tr>\n<td>Battery-Mode Frequency<\/td>\n<td>50 Hz \u00b10,1 Hz ho\u1eb7c 60 Hz \u00b10,1 Hz<\/td>\n<\/tr>\n<tr>\n<td>H\u1ec7 s\u1ed1 \u0111\u1ec9nh<\/td>\n<td>3:1 Max<\/td>\n<\/tr>\n<tr>\n<td>\u0110\u1ed9 m\u00e9o h\u00e0i t\u1ed5ng (THD) \u0111\u1ea7u ra<\/td>\n<td>\u22643% Linear \/ \u22645% Non-linear<\/td>\n<\/tr>\n<tr>\n<td>Mains-to-Battery Transfer<\/td>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<td>Inverter-to-Bypass Transfer<\/td>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<td>AC Mode Efficiency<\/td>\n<td>88%<\/td>\n<\/tr>\n<tr>\n<td>Battery Mode Efficiency<\/td>\n<td>92%<\/td>\n<\/tr>\n<tr>\n<td>S\u1ed1 l\u01b0\u1ee3ng pin<\/td>\n<td>16 \/ 18 pcs<\/td>\n<\/tr>\n<tr>\n<td>D\u00f2ng \u0111i\u1ec7n s\u1ea1c t\u1ed1i \u0111a<\/td>\n<td>8A<\/td>\n<\/tr>\n<tr>\n<td>K\u00edch th\u01b0\u1edbc<\/td>\n<td>562 \u00d7 250 \u00d7 830 mm<\/td>\n<\/tr>\n<tr>\n<td>Tr\u1ecdng l\u01b0\u1ee3ng t\u1ecbnh<\/td>\n<td>62 kg<\/td>\n<\/tr>\n<tr>\n<td>Nhi\u1ec7t \u0111\u1ed9 ho\u1ea1t \u0111\u1ed9ng<\/td>\n<td>0\u201350\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>\u0110\u1ed9 \u1ea9m t\u01b0\u01a1ng \u0111\u1ed1i<\/td>\n<td>&lt;95%, Non-Condensing<\/td>\n<\/tr>\n<tr>\n<td>\u0110\u1ed9 cao ho\u1ea1t \u0111\u1ed9ng<\/td>\n<td>&lt;1.000 m<\/td>\n<\/tr>\n<tr>\n<td>Ti\u1ebfng \u1ed3n<\/td>\n<td>&lt;58dB \u1edf kho\u1ea3ng c\u00e1ch 1m<\/td>\n<\/tr>\n<tr>\n<td>Giao ti\u1ebfp<\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td>SNMP<\/td>\n<td>Optional<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n<h2>Nh\u1eefng l\u1ee3i \u00edch ch\u00ednh<\/h2>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul>\n<li><strong>6kVA \/ 4.8kW Capacity:<\/strong> Designed for critical single-phase loads requiring up to 4.8kW rated active power.<\/li>\n<li><strong>1\/1 Phase Architecture:<\/strong> Single-phase input and single-phase output match common single-phase critical-power applications.<\/li>\n<li><strong>Online Power Protection:<\/strong> Provides continuous power conditioning for sensitive electrical and electronic loads.<\/li>\n<li><strong>0ms Transfer Time:<\/strong> Maintains output during mains-to-battery transition according to the reference specification.<\/li>\n<li><strong>Stable Output:<\/strong> Supports 208\/220\/230VAC output with \u00b11% voltage regulation.<\/li>\n<li><strong>Configurable Battery System:<\/strong> Supports 16\/18-battery configurations according to the approved system configuration.<\/li>\n<li><strong>Communication and Monitoring:<\/strong> RS-232\/USB communication with optional SNMP network management.<\/li>\n<li><strong>Project-Based Configuration:<\/strong> Battery runtime and system requirements can be reviewed according to the connected load and site conditions.<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2>What Does 1\/1 Phase Mean in a UPS?<\/h2>\n<p>A 1\/1 phase UPS uses single-phase AC power at the input and supplies single-phase AC power at the output.<\/p>\n<p>This architecture is suitable for facilities where the utility supply and protected equipment both operate on single-phase power, including IT systems, telecom equipment, medical devices, industrial controllers and other critical electronic loads.<\/p>\n<p>The DAXIN 1\/1 6K(L) uses this single-phase input and single-phase output configuration for applications requiring online backup power protection.<\/p>\n<h2>6kVA vs 10kVA: Which UPS Should I Choose?<\/h2>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"6274\" data-end=\"6377\">The DAXIN 1\/1 6K(L) is rated at 6kVA\/4.8kW, while the 1\/1 10K(L) reference model is rated at 10kVA\/8kW.<\/p>\n<p data-start=\"6382\" data-end=\"6524\">Select between them according to the actual connected load, required operating margin, expected future expansion and backup-time requirements.<\/p>\n<p data-start=\"6529\" data-end=\"6684\">A UPS should not be selected only by nominal kVA. Consider the actual load in kW, startup or peak demand, battery runtime and future capacity requirements.<\/p>\n<h2>\nTh\u00f4ng tin v\u1ec1 s\u1ea3n ph\u1ea9m v\u00e0 t\u00e0i li\u1ec7u tham kh\u1ea3o k\u1ef9 thu\u1eadt<\/h2>\n<figure class=\"wp-block-image size-full\"><figcaption>Technical Reference for DAXIN 1\/1 6K(L) Low-Frequency 1\/1 Phase UPS.<\/figcaption><\/figure>\n<h2>C\u00e1c \u1ee9ng d\u1ee5ng \u0111i\u1ec3n h\u00ecnh<\/h2>\n<ul data-start=\"6822\" data-end=\"7131\">\n<li data-section-id=\"150ngxp\" data-start=\"6822\" data-end=\"6853\">Server rooms and IT equipment<\/li>\n<li data-section-id=\"12pptsc\" data-start=\"6854\" data-end=\"6889\">Telecom and communication systems<\/li>\n<li data-section-id=\"18mpx12\" data-start=\"6890\" data-end=\"6935\">Industrial control and automation equipment<\/li>\n<li data-section-id=\"9i1azp\" data-start=\"6936\" data-end=\"6970\">Medical and diagnostic equipment<\/li>\n<li data-section-id=\"16dlkl6\" data-start=\"6971\" data-end=\"7002\">H\u1ec7 th\u1ed1ng ng\u00e2n h\u00e0ng v\u00e0 t\u00e0i ch\u00ednh<\/li>\n<li data-section-id=\"39g3c\" data-start=\"7003\" data-end=\"7040\">Thi\u1ebft b\u1ecb an ninh v\u00e0 gi\u00e1m s\u00e1t<\/li>\n<li data-section-id=\"pzopkc\" data-start=\"7041\" data-end=\"7084\">Transportation and infrastructure systems<\/li>\n<li data-section-id=\"y5kyas\" data-start=\"7085\" data-end=\"7131\">Other critical single-phase electrical loads<\/li>\n<\/ul>\n<h2>How to Select the Right 6kVA Single-Phase UPS<\/h2>\n<p>Select the UPS according to the actual connected load in kW and kVA, input and output voltage, required backup time, battery configuration, startup or peak load, communication requirements and installation environment.<\/p>\n<p>For the DAXIN 1\/1 6K(L), confirm that the site provides the required single-phase input supply and that the protected equipment requires single-phase output.<\/p>\n<p>Provide DAXIN ENERGY with the load list, site voltage, required runtime, battery requirements, communication interfaces and installation conditions to determine the appropriate UPS configuration.<\/p>\n<h2>C\u00e1c c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3>S\u1ea3n ph\u1ea9m n\u00e0y c\u00f3 th\u1ec3 \u0111\u01b0\u1ee3c t\u00f9y ch\u1ec9nh cho m\u1ed9t d\u1ef1 \u00e1n c\u1ee5 th\u1ec3 kh\u00f4ng?<\/h3>\n<p>\u0110\u00fang v\u1eady. C\u00f3 th\u1ec3 r\u00e0 so\u00e1t c\u00e1c y\u1ebfu t\u1ed1 nh\u01b0 c\u1ea5u h\u00ecnh \u0111i\u1ec7n, th\u1eddi l\u01b0\u1ee3ng ho\u1ea1t \u0111\u1ed9ng c\u1ee7a pin, h\u1ec7 th\u1ed1ng truy\u1ec1n th\u00f4ng, ch\u1ebf \u0111\u1ed9 bypass, c\u00e1ch b\u1ed1 tr\u00ed t\u1ee7 v\u00e0 c\u00e1c ph\u1ee5 ki\u1ec7n c\u1ee7a d\u1ef1 \u00e1n \u0111\u1ec3 \u0111\u1ea3m b\u1ea3o ph\u00f9 h\u1ee3p v\u1edbi c\u00e1c y\u00eau c\u1ea7u t\u1ea1i hi\u1ec7n tr\u01b0\u1eddng.<\/p>\n<h3>T\u1ea5t c\u1ea3 c\u00e1c ch\u1ec9 s\u1ed1 k\u1ef9 thu\u1eadt c\u00f3 \u0111\u01b0\u1ee3c \u00e1p d\u1ee5ng chung cho to\u00e0n b\u1ed9 lo\u1ea1t phim kh\u00f4ng?<\/h3>\n<p>Kh\u00f4ng. C\u00e1c th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt v\u00e0 ch\u1ee9c n\u0103ng c\u00f3 th\u1ec3 kh\u00e1c nhau t\u00f9y theo t\u1eebng m\u1eabu v\u00e0 c\u1ea5u h\u00ecnh. Vui l\u00f2ng tham kh\u1ea3o b\u1ea3ng th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt d\u00e0nh ri\u00eang cho d\u1ef1 \u00e1n l\u00e0m t\u00e0i li\u1ec7u tham kh\u1ea3o ch\u00ednh th\u1ee9c.<\/p>\n<h3>DAXIN ENERGY c\u00f3 th\u1ec3 h\u1ed7 tr\u1ee3 vi\u1ec7c l\u1ef1a ch\u1ecdn h\u1ec7 th\u1ed1ng kh\u00f4ng?<\/h3>\n<p>V\u00e2ng. Vui l\u00f2ng cung c\u1ea5p danh s\u00e1ch t\u1ea3i, pha v\u00e0 \u0111i\u1ec7n \u00e1p, th\u1eddi gian ho\u1ea1t \u0111\u1ed9ng y\u00eau c\u1ea7u, m\u1ee5c ti\u00eau d\u1ef1 ph\u00f2ng, c\u00e1c y\u00eau c\u1ea7u v\u1ec1 truy\u1ec1n th\u00f4ng v\u00e0 m\u00f4i tr\u01b0\u1eddng l\u1eafp \u0111\u1eb7t.<\/p>\n<h2>Y\u00eau c\u1ea7u c\u1ea5u h\u00ecnh d\u1ef1 \u00e1n<\/h2>\n<p>Vui l\u00f2ng g\u1eedi d\u1eef li\u1ec7u t\u1ea3i, s\u01a1 \u0111\u1ed3 m\u1ea1ch \u0111\u01a1n, th\u1eddi gian d\u1ef1 ph\u00f2ng c\u1ea7n thi\u1ebft v\u00e0 \u0111i\u1ec1u ki\u1ec7n t\u1ea1i hi\u1ec7n tr\u01b0\u1eddng \u0111\u1ec3 nh\u1eadn \u0111\u01b0\u1ee3c \u0111\u1ec1 xu\u1ea5t v\u1ec1 b\u1ed9 l\u01b0u \u0111i\u1ec7n (UPS) ho\u1eb7c \u1eafc-quy ph\u00f9 h\u1ee3p v\u1edbi nhu c\u1ea7u c\u1ee7a qu\u00fd kh\u00e1ch.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1o0oct3\" data-start=\"8394\" data-end=\"8448\">What is the rated capacity of the DAXIN 1\/1 6K(L)?<\/h3>\n<p data-start=\"8450\" data-end=\"8499\">The reference model is rated at 6kVA \/ 4.8kW.<\/p>\n<h3 data-section-id=\"1sji83t\" data-start=\"8501\" data-end=\"8530\">What does 1\/1 phase mean?<\/h3>\n<p data-start=\"8532\" data-end=\"8610\">It means the UPS uses single-phase input and supplies single-phase output.<\/p>\n<h3 data-section-id=\"14q0qkz\" data-start=\"8612\" data-end=\"8665\">Th\u1eddi gian chuy\u1ec3n \u0111\u1ed5i khi m\u1ea5t \u0111i\u1ec7n l\u00e0 bao l\u00e2u?<\/h3>\n<p data-start=\"8667\" data-end=\"8735\">The reference specification lists 0ms mains-to-battery transfer.<\/p>\n<h3 data-section-id=\"1b2caab\" data-start=\"8737\" data-end=\"8782\">What output voltage does the UPS support?<\/h3>\n<p data-start=\"8784\" data-end=\"8875\">The reference configuration supports 208\/220\/230VAC output with \u00b11% voltage regulation.<\/p>\n<h3 data-section-id=\"9fb4w2\" data-start=\"8877\" data-end=\"8915\">Can battery runtime be customized?<\/h3>\n<p data-start=\"8917\" data-end=\"9044\">Yes. Runtime depends on connected load, battery configuration, battery condition, temperature and required backup duration.<\/p>\n<h3 data-section-id=\"2u2uj0\" data-start=\"9046\" data-end=\"9089\">Thi\u1ebft b\u1ecb UPS c\u00f3 h\u1ed7 tr\u1ee3 gi\u00e1m s\u00e1t t\u1eeb xa kh\u00f4ng?<\/h3>\n<p data-start=\"9091\" data-end=\"9195\">The reference configuration supports RS-232\/USB communication with optional SNMP network management.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN 1\/1 6K(L) is a 6kVA\/4.8kW low-frequency online UPS designed for single-phase input and single-phase output critical power applications. Featuring 0ms transfer to battery operation, 208\/220\/230VAC output, configurable 16\/18-battery operation, RS-232\/USB communication and optional SNMP monitoring, it is suitable for control systems, telecom, healthcare, finance, transportation, security and other critical single-phase loads.<\/p>","protected":false},"featured_media":4902,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[107,99,97],"product_tag":[],"class_list":["post-2908","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-low-frequency-1-1-phase-ups","product_cat-low-frequency-ups","product_cat-ups-solutions","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product\/2908","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/comments?post=2908"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media\/4902"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media?parent=2908"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_brand?post=2908"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_cat?post=2908"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_tag?post=2908"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}