{"id":2314,"date":"2026-07-17T20:12:07","date_gmt":"2026-07-17T12:12:07","guid":{"rendered":"https:\/\/btrytech.com\/?post_type=product&#038;p=2314"},"modified":"2026-08-13T22:07:06","modified_gmt":"2026-08-13T14:07:06","slug":"bo-luu-dien-truc-tuyen-ex3c3-100-kva","status":"publish","type":"product","link":"https:\/\/btrytech.com\/vi\/product\/ex3c3-100kva-online-ups\/","title":{"rendered":"B\u1ed9 l\u01b0u \u0111i\u1ec7n tr\u1ef1c tuy\u1ebfn EX3C3 100kVA | B\u1ed9 l\u01b0u \u0111i\u1ec7n ba pha \u2013 DAXIN ENERGY"},"content":{"rendered":"<p><!-- DAXIN-HF-SEO-GEO-04-START --><\/p>\n<section class=\"daxin-customer-selection-guide\">\n<h2>Li\u1ec7u UPS n\u00e0y c\u00f3 ph\u00f9 h\u1ee3p v\u1edbi d\u1ef1 \u00e1n c\u1ee7a b\u1ea1n kh\u00f4ng?<\/h2>\n<p>The DAXIN EX3C3 100kVA is a true online double-conversion UPS for critical three-phase loads that require stable voltage, low output distortion and seamless battery transition.<\/p>\n<p>It provides a practical capacity point for facilities that have outgrown smaller UPS systems but do not require a 120kVA or larger platform.<\/p>\n<h2>C\u00e1c \u1ee9ng d\u1ee5ng \u0111i\u1ec3n h\u00ecnh<\/h2>\n<ul>\n<li>Data centers and server facilities<\/li>\n<li>Industrial automation<\/li>\n<li>Healthcare and laboratories<\/li>\n<li>Telecommunications and financial services<\/li>\n<\/ul>\n<h2>Nh\u1eefng \u0111i\u1ec1u c\u1ea7n x\u00e1c nh\u1eadn tr\u01b0\u1edbc khi \u0111\u1eb7t h\u00e0ng<\/h2>\n<ul>\n<li>Load level and overload behavior<\/li>\n<li>Input\/output voltage and frequency<\/li>\n<li>Battery autonomy and charging current<\/li>\n<li>Monitoring, bypass and service requirements<\/li>\n<\/ul>\n<h2>C\u00e1c c\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h2>\n<h3>T\u00f4i n\u00ean ch\u1ecdn c\u00f4ng su\u1ea5t UPS nh\u01b0 th\u1ebf n\u00e0o?<\/h3>\n<p>H\u00e3y b\u1eaft \u0111\u1ea7u t\u1eeb m\u1ee9c t\u1ea3i li\u00ean t\u1ee5c \u0111\u00e3 \u0111o \u0111\u01b0\u1ee3c, m\u1ee9c t\u1ea3i kh\u1edfi \u0111\u1ed9ng ho\u1eb7c m\u1ee9c t\u1ea3i \u0111\u1ec9nh v\u00e0 k\u1ebf ho\u1ea1ch m\u1edf r\u1ed9ng d\u1ef1 ki\u1ebfn. DAXIN ENERGY c\u00f3 th\u1ec3 r\u00e0 so\u00e1t danh s\u00e1ch t\u1ea3i v\u00e0 \u0111\u1ec1 xu\u1ea5t m\u1ed9t bi\u00ean \u0111\u1ed9 v\u1eadn h\u00e0nh h\u1ee3p l\u00fd.<\/p>\n<h3>Th\u1eddi l\u01b0\u1ee3ng s\u1eed d\u1ee5ng pin \u0111\u01b0\u1ee3c x\u00e1c \u0111\u1ecbnh nh\u01b0 th\u1ebf n\u00e0o?<\/h3>\n<p>Th\u1eddi gian ho\u1ea1t \u0111\u1ed9ng ph\u1ee5 thu\u1ed9c v\u00e0o t\u1ea3i, \u0111i\u1ec7n \u00e1p pin, dung l\u01b0\u1ee3ng pin, tu\u1ed5i th\u1ecd pin, nhi\u1ec7t \u0111\u1ed9 v\u00e0 hi\u1ec7u su\u1ea5t c\u1ee7a b\u1ed9 bi\u1ebfn t\u1ea7n. Vui l\u00f2ng cung c\u1ea5p th\u1eddi gian d\u1ef1 ph\u00f2ng c\u1ea7n thi\u1ebft v\u00e0 t\u1ea3i th\u00f4ng th\u01b0\u1eddng \u0111\u1ec3 ti\u1ebfn h\u00e0nh t\u00ednh to\u00e1n cho d\u1ef1 \u00e1n.<\/p>\n<h3>B\u1ed9 l\u01b0u \u0111i\u1ec7n n\u00e0y c\u00f3 th\u1ec3 ho\u1ea1t \u0111\u1ed9ng c\u00f9ng v\u1edbi m\u00e1y ph\u00e1t \u0111i\u1ec7n ho\u1eb7c h\u1ec7 th\u1ed1ng gi\u00e1m s\u00e1t t\u1eeb xa kh\u00f4ng?<\/h3>\n<p>Kh\u1ea3 n\u0103ng t\u01b0\u01a1ng th\u00edch gi\u1eefa m\u00e1y ph\u00e1t \u0111i\u1ec7n v\u00e0 h\u1ec7 th\u1ed1ng gi\u00e1m s\u00e1t ph\u1ee5 thu\u1ed9c v\u00e0o m\u1eabu m\u00e1y v\u00e0 c\u1ea5u h\u00ecnh \u0111\u00e3 ch\u1ecdn. Tr\u01b0\u1edbc khi \u0111\u1eb7t h\u00e0ng, vui l\u00f2ng x\u00e1c nh\u1eadn c\u00f4ng su\u1ea5t m\u00e1y ph\u00e1t \u0111i\u1ec7n, \u0111\u1ed9 \u1ed5n \u0111\u1ecbnh t\u1ea7n s\u1ed1 c\u0169ng nh\u01b0 c\u00e1c giao di\u1ec7n RS-232, RS-485, USB, Modbus ho\u1eb7c SNMP c\u1ea7n thi\u1ebft.<\/p>\n<h2>Y\u00eau c\u1ea7u c\u1ea5u h\u00ecnh d\u1ef1 \u00e1n<\/h2>\n<p>Vui l\u00f2ng g\u1eedi cho DAXIN ENERGY danh s\u00e1ch t\u1ea3i, \u0111i\u1ec7n \u00e1p t\u1ea1i c\u00f4ng tr\u00ecnh, th\u1eddi gian ho\u1ea1t \u0111\u1ed9ng y\u00eau c\u1ea7u, m\u00f4i tr\u01b0\u1eddng l\u1eafp \u0111\u1eb7t, c\u0169ng nh\u01b0 c\u00e1c y\u00eau c\u1ea7u v\u1ec1 truy\u1ec1n th\u00f4ng v\u00e0 d\u1ef1 ph\u00f2ng. C\u1ea5u h\u00ecnh cu\u1ed1i c\u00f9ng s\u1ebd tu\u00e2n theo \u0111\u1ec1 xu\u1ea5t k\u1ef9 thu\u1eadt \u0111\u00e3 \u0111\u01b0\u1ee3c ph\u00ea duy\u1ec7t.<\/p>\n<\/section>\n<p><!-- DAXIN-HF-SEO-GEO-04-END --><\/p>\n<p><!-- DAXIN-HF-VIDEO-04-START --><\/p>\n<section class=\"daxin-product-video\">\n<h2>Video gi\u1edbi thi\u1ec7u th\u00eam v\u1ec1 s\u1ea3n ph\u1ea9m UPS t\u1ea7n s\u1ed1 cao DAXIN<\/h2>\n<p>H\u00e3y xem video gi\u1edbi thi\u1ec7u s\u1ea3n ph\u1ea9m \u0111\u1ec3 t\u00ecm hi\u1ec3u v\u1ec1 c\u1ea5u h\u00ecnh c\u1ee7a b\u1ed9 l\u01b0u \u0111i\u1ec7n (UPS), giao di\u1ec7n v\u1eadn h\u00e0nh v\u00e0 \u0111\u1ecbnh v\u1ecb \u1ee9ng d\u1ee5ng. C\u1ea5u h\u00ecnh \u0111i\u1ec7n cu\u1ed1i c\u00f9ng s\u1ebd tu\u00e2n theo \u0111\u1ec1 xu\u1ea5t k\u1ef9 thu\u1eadt \u0111\u00e3 \u0111\u01b0\u1ee3c ph\u00ea duy\u1ec7t.<\/p>\n<div class=\"daxin-product-video-item\">\n<h3>Professional-Grade 100KVA UPS System with True Online Double Conversion Technology<\/h3>\n<figure class=\"wp-block-video\"><video src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-high-frequency-ups-befadb703763.mp4\" poster=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2314-gallery-01.webp?wsr\" preload=\"metadata\" controls=\"controls\" width=\"306\" height=\"306\">Tr\u00ecnh duy\u1ec7t c\u1ee7a b\u1ea1n kh\u00f4ng h\u1ed7 tr\u1ee3 th\u1ebb video.<\/video><figcaption>Professional-Grade 100KVA UPS System with True Online Double Conversion Technology &#8211; DAXIN ENERGY.<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<p><!-- DAXIN-HF-VIDEO-04-END --><\/p>\n<h2>DAXIN ENERGY EX3C3 100kVA Three-Phase Online UPS<\/h2>\n<p>DAXIN ENERGY EX3C3 100kVA three-phase online UPS is designed for data centers,<br \/>\ntelecom facilities, industrial production lines, commercial buildings and critical<br \/>\ninfrastructure that require stable, continuous and clean power protection. With true<br \/>\nc\u1ea5u tr\u00fac chuy\u1ec3n \u0111\u1ed5i k\u00e9p tr\u1ef1c tuy\u1ebfn, h\u1ec7 s\u1ed1 c\u00f4ng su\u1ea5t \u0111\u1ea7u v\u00e0o cao, d\u1ea3i \u0111i\u1ec7n \u00e1p \u0111\u1ea7u v\u00e0o AC r\u1ed9ng<br \/>\nrange and intelligent monitoring options, it delivers reliable 100kW backup power<br \/>\nfor mission-critical equipment.<\/p>\n<h3>C\u00e1c t\u00ednh n\u0103ng ch\u00ednh<\/h3>\n<ul>\n<li>C\u1ea5u tr\u00fac UPS chuy\u1ec3n \u0111\u1ed5i k\u00e9p tr\u1ef1c tuy\u1ebfn th\u1ef1c s\u1ef1, \u0111\u1ea3m b\u1ea3o \u0111i\u1ec7n \u00e1p v\u00e0 t\u1ea7n s\u1ed1 \u0111\u1ea7u ra \u1ed5n \u0111\u1ecbnh.<\/li>\n<li>100kVA \/ 100kW power capacity for high-demand critical power applications.<\/li>\n<li>\u0110\u1ea7u ra s\u00f3ng sin thu\u1ea7n t\u00fay gi\u00fap b\u1ea3o v\u1ec7 m\u00e1y ch\u1ee7, thi\u1ebft b\u1ecb vi\u1ec5n th\u00f4ng, h\u1ec7 th\u1ed1ng c\u00f4ng nghi\u1ec7p v\u00e0 c\u00e1c thi\u1ebft b\u1ecb ch\u00ednh x\u00e1c.<\/li>\n<li>D\u1ea3i \u0111i\u1ec7n \u00e1p \u0111\u1ea7u v\u00e0o AC r\u1ed9ng gi\u00fap gi\u1ea3m thi\u1ec3u t\u00ecnh tr\u1ea1ng x\u1ea3 pin kh\u00f4ng c\u1ea7n thi\u1ebft trong c\u00e1c m\u00f4i tr\u01b0\u1eddng l\u01b0\u1edbi \u0111i\u1ec7n kh\u00f4ng \u1ed5n \u0111\u1ecbnh.<\/li>\n<li>C\u00f4ng ngh\u1ec7 PFC ti\u00ean ti\u1ebfn gi\u00fap \u0111\u1ea3m b\u1ea3o h\u1ec7 s\u1ed1 c\u00f4ng su\u1ea5t \u0111\u1ea7u v\u00e0o cao v\u00e0 gi\u1ea3m thi\u1ec3u \u00f4 nhi\u1ec5m s\u00f3ng h\u00e0i.<\/li>\n<li>Thi\u1ebft k\u1ebf t\u01b0\u01a1ng th\u00edch v\u1edbi m\u00e1y ph\u00e1t \u0111i\u1ec7n; c\u00f4ng su\u1ea5t m\u00e1y ph\u00e1t \u0111i\u1ec7n \u0111\u01b0\u1ee3c khuy\u1ebfn ngh\u1ecb l\u00e0 g\u1ea5p 2 l\u1ea7n c\u00f4ng su\u1ea5t c\u1ee7a b\u1ed9 l\u01b0u \u0111i\u1ec7n (UPS).<\/li>\n<li>Th\u1eddi gian chuy\u1ec3n m\u1ea1ch b\u1eb1ng kh\u00f4ng \u0111\u1ea3m b\u1ea3o kh\u1ea3 n\u0103ng b\u1ea3o v\u1ec7 ngu\u1ed3n \u0111i\u1ec7n li\u00ean t\u1ee5c trong tr\u01b0\u1eddng h\u1ee3p m\u1ea5t \u0111i\u1ec7n l\u01b0\u1edbi ho\u1eb7c bi\u1ebfn \u0111\u1ed9ng \u0111i\u1ec7n \u00e1p.<\/li>\n<li>RS232, RS485 v\u00e0 SNMP (t\u00f9y ch\u1ecdn) cho ph\u00e9p gi\u00e1m s\u00e1t UPS t\u1eeb xa v\u00e0 qu\u1ea3n l\u00fd ngu\u1ed3n \u0111i\u1ec7n th\u00f4ng minh.<\/li>\n<\/ul>\n<h3>\u1ee8ng d\u1ee5ng<\/h3>\n<ul>\n<li>Trung t\u00e2m d\u1eef li\u1ec7u v\u00e0 ph\u00f2ng m\u00e1y ch\u1ee7<\/li>\n<li>Tr\u1ea1m g\u1ed1c vi\u1ec5n th\u00f4ng v\u00e0 ph\u00f2ng \u0111i\u1ec1u khi\u1ec3n th\u00f4ng tin li\u00ean l\u1ea1c<\/li>\n<li>T\u1ef1 \u0111\u1ed9ng h\u00f3a c\u00f4ng nghi\u1ec7p v\u00e0 thi\u1ebft b\u1ecb s\u1ea3n xu\u1ea5t<\/li>\n<li>Ngu\u1ed3n \u0111i\u1ec7n d\u1ef1 ph\u00f2ng cho c\u00e1c t\u00f2a nh\u00e0 th\u01b0\u01a1ng m\u1ea1i v\u00e0 c\u01a1 s\u1edf v\u1eadt ch\u1ea5t<\/li>\n<li>Ph\u00f2ng \u0111i\u1ec1u khi\u1ec3n, h\u1ec7 th\u1ed1ng an ninh v\u00e0 c\u01a1 s\u1edf h\u1ea1 t\u1ea7ng quan tr\u1ecdng<\/li>\n<\/ul>\n<h3>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<\/h3>\n<table>\n<tbody>\n<tr>\n<th>M\u1eabu<\/th>\n<td>EX3C3-100kVA<\/td>\n<\/tr>\n<tr>\n<th>C\u00f4ng su\u1ea5t<\/th>\n<td>100kVA \/ 100kW<\/td>\n<\/tr>\n<tr>\n<th>C\u1ea5u tr\u00fac m\u1ea1ng UPS<\/th>\n<td>B\u1ed9 l\u01b0u \u0111i\u1ec7n (UPS) chuy\u1ec3n \u0111\u1ed5i k\u00e9p tr\u1ef1c tuy\u1ebfn th\u1ef1c s\u1ef1<\/td>\n<\/tr>\n<tr>\n<th>Giai \u0111o\u1ea1n nh\u1eadp li\u1ec7u<\/th>\n<td>Ba pha + d\u00e2y trung t\u00ednh<\/td>\n<\/tr>\n<tr>\n<th>D\u1ea3i \u0111i\u1ec7n \u00e1p \u0111\u1ea7u v\u00e0o<\/th>\n<td>110VAC (Ph-N) \u00b13% khi t\u1ea3i 50%; 176VAC (Ph-N) \u00b13% khi t\u1ea3i 100%<\/td>\n<\/tr>\n<tr>\n<th>Chuy\u1ec3n \u0111\u1ed5i \u0111i\u1ec7n \u00e1p \u0111\u1ea7u v\u00e0o cao<\/th>\n<td>300 VAC (L-N) \u00b131 TP3T khi t\u1ea3i 501 TP3T; 276 VAC (L-N) \u00b131 TP3T khi t\u1ea3i 1001 TP3T<\/td>\n<\/tr>\n<tr>\n<th>D\u1ea3i t\u1ea7n s\u1ed1 \u0111\u1ea7u v\u00e0o<\/th>\n<td>T\u1ef1 \u0111\u1ed9ng ch\u1ecdn 50 \/ 60 Hz<\/td>\n<\/tr>\n<tr>\n<th>H\u1ec7 s\u1ed1 c\u00f4ng su\u1ea5t \u0111\u1ea7u v\u00e0o<\/th>\n<td>&gt;0,99 khi t\u1ea3i 100%<\/td>\n<\/tr>\n<tr>\n<th>\u0110i\u1ec7n \u00e1p \u0111\u1ea7u ra<\/th>\n<td>380 \/ 400 \/ 415VAC, phase-to-phase<\/td>\n<\/tr>\n<tr>\n<th>\u0110i\u1ec1u ch\u1ec9nh \u0111i\u1ec7n \u00e1p xoay chi\u1ec1u<\/th>\n<td>\u00b10,31 TP3T<\/td>\n<\/tr>\n<tr>\n<th>T\u1ea7n s\u1ed1 \u0111\u1ed3ng b\u1ed9<\/th>\n<td>46 Hz\u201354 Hz ho\u1eb7c 56 Hz\u201364 Hz<\/td>\n<\/tr>\n<tr>\n<th>T\u1ea7n su\u1ea5t ch\u1ebf \u0111\u1ed9 pin<\/th>\n<td>50 Hz \u00b10,1 Hz ho\u1eb7c 60 Hz \u00b10,1 Hz<\/td>\n<\/tr>\n<tr>\n<th>T\u1ef7 l\u1ec7 \u0111\u1ec9nh hi\u1ec7n t\u1ea1i<\/th>\n<td>T\u1ed1i \u0111a 3:1<\/td>\n<\/tr>\n<tr>\n<th>\u0110\u1ed9 m\u00e9o h\u00e0i t\u1ed5ng (THD) \u0111\u1ea7u ra<\/th>\n<td>THD \u22641% khi t\u1ea3i tuy\u1ebfn t\u00ednh; THD \u22642% khi t\u1ea3i phi tuy\u1ebfn t\u00ednh<\/td>\n<\/tr>\n<tr>\n<th>Th\u1eddi gian chuy\u1ec3n nh\u01b0\u1ee3ng<\/th>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<th>Kh\u1ea3 n\u0103ng ch\u1ecbu qu\u00e1 t\u1ea3i<\/th>\n<td>100%-110%: 60 ph\u00fat; 110%-125%: 10 ph\u00fat; 125%-150%: 1 ph\u00fat; &gt;150%: b\u1ea3o v\u1ec7 ngay l\u1eadp t\u1ee9c<\/td>\n<\/tr>\n<tr>\n<th>Hi\u1ec7u qu\u1ea3<\/th>\n<td>&gt;96,5% \u1edf ch\u1ebf \u0111\u1ed9 AC; &gt;96,5% \u1edf ch\u1ebf \u0111\u1ed9 pin<\/td>\n<\/tr>\n<tr>\n<th>S\u1ed1 l\u01b0\u1ee3ng pin<\/th>\n<td>32\u201340 vi\u00ean pin, c\u00f3 th\u1ec3 \u0111i\u1ec1u ch\u1ec9nh<\/td>\n<\/tr>\n<tr>\n<th>D\u00f2ng \u0111i\u1ec7n s\u1ea1c t\u1ed1i \u0111a<\/th>\n<td>2-36A \u00b110%, c\u00e0i \u0111\u1eb7t s\u1eb5n 2A<\/td>\n<\/tr>\n<tr>\n<th>K\u00edch th\u01b0\u1edbc<\/th>\n<td>1000 \u00d7 430 \u00d7 1200 mm<\/td>\n<\/tr>\n<tr>\n<th>Tr\u1ecdng l\u01b0\u1ee3ng t\u1ecbnh<\/th>\n<td>200 kg<\/td>\n<\/tr>\n<tr>\n<th>Nhi\u1ec7t \u0111\u1ed9 ho\u1ea1t \u0111\u1ed9ng<\/th>\n<td>0\u00b0C\u201340\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>\u0110\u1ed9 \u1ea9m t\u01b0\u01a1ng \u0111\u1ed1i<\/th>\n<td>&lt;95%, kh\u00f4ng ng\u01b0ng t\u1ee5<\/td>\n<\/tr>\n<tr>\n<th>Ti\u1ebfng \u1ed3n<\/th>\n<td>&lt;70dB @ 1m<\/td>\n<\/tr>\n<tr>\n<th>\u0110\u1ed9 cao<\/th>\n<td>&lt;1.000 m<\/td>\n<\/tr>\n<tr>\n<th>Giao di\u1ec7n truy\u1ec1n th\u00f4ng<\/th>\n<td>RS232 \/ USB; h\u1ed7 tr\u1ee3 qu\u1ea3n l\u00fd SNMP (t\u00f9y ch\u1ecdn)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>C\u00e2u h\u1ecfi th\u01b0\u1eddng g\u1eb7p<\/h3>\n<h4>What is the DAXIN ENERGY EX3C3 100kVA online UPS used for?<\/h4>\n<p>The DAXIN ENERGY EX3C3 100kVA online UPS is used for data centers, telecom rooms,<br \/>\nindustrial facilities, commercial buildings and critical infrastructure that require<br \/>\nstable three-phase backup power and continuous power protection.<\/p>\n<h4>Is the EX3C3 100kVA UPS a true online double-conversion UPS?<\/h4>\n<p>Yes. The EX3C3 100kVA UPS uses true online double-conversion technology to provide<br \/>\nstable voltage, stable frequency and clean sine wave output for sensitive equipment.<\/p>\n<h4>Does the EX3C3 100kVA UPS support generator input?<\/h4>\n<p>\u0110\u00fang v\u1eady. B\u1ed9 l\u01b0u \u0111i\u1ec7n (UPS) t\u01b0\u01a1ng th\u00edch v\u1edbi ngu\u1ed3n \u0111i\u1ec7n t\u1eeb m\u00e1y ph\u00e1t \u0111i\u1ec7n. \u0110\u1ec3 \u0111\u1ea3m b\u1ea3o ho\u1ea1t \u0111\u1ed9ng \u1ed5n \u0111\u1ecbnh, m\u00e1y ph\u00e1t \u0111i\u1ec7n<br \/>\nC\u00f4ng su\u1ea5t \u0111\u01b0\u1ee3c khuy\u1ebfn ngh\u1ecb ph\u1ea3i g\u1ea5p \u00edt nh\u1ea5t 2 l\u1ea7n c\u00f4ng su\u1ea5t c\u1ee7a b\u1ed9 l\u01b0u \u0111i\u1ec7n (UPS).<\/p>\n<h4>Can the EX3C3 100kVA UPS be monitored remotely?<\/h4>\n<p>Yes. The UPS supports RS232 and USB communication, with optional SNMP network<br \/>\nmanagement for remote monitoring, alarm notification and power management.<\/p>\n<h4>What applications are suitable for a 100kVA three-phase online UPS?<\/h4>\n<p>A 100kVA three-phase online UPS is suitable for data centers, server rooms, telecom<br \/>\nsystems, manufacturing equipment, control rooms, security systems and other<br \/>\nmission-critical electrical loads.<\/p>\n<h4>What is the output capacity of the EX3C3 100kVA UPS?<\/h4>\n<p>The EX3C3 100kVA model provides 100kVA \/ 100kW output capacity, making it suitable<br \/>\nfor high-power industrial and commercial backup power applications.<\/p>\n<h4>Does the UPS provide zero transfer time?<\/h4>\n<p>Yes. As a true online UPS, the EX3C3 100kVA provides 0ms transfer time, helping<br \/>\nprotect critical loads from power interruption, voltage fluctuation and grid instability.<\/p>\n<h4>What battery configuration does the EX3C3 100kVA UPS support?<\/h4>\n<p>The EX3C3 100kVA UPS supports 32-40 batteries, adjustable according to project<br \/>\nrequirements and backup time needs.<\/p>\n<figure id=\"attachment_2232\" class=\"wp-caption aligncenter\" style=\"width: 982px;\" aria-describedby=\"caption-attachment-2232\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2232\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2314-detail-01.webp\" alt=\"EX3C3 100kVA Online UPS | Three-Phase UPS - DAXIN ENERGY technical detail 1 by DAXIN ENERGY\" width=\"982\" height=\"664\" \/><figcaption id=\"caption-attachment-2232\" class=\"wp-caption-text\">C\u00e1c t\u00ednh n\u0103ng n\u1ed5i b\u1eadt c\u1ee7a b\u1ed9 l\u01b0u \u0111i\u1ec7n tr\u1ef1c tuy\u1ebfn (UPS) DAXIN ENERGY, bao g\u1ed3m ngu\u1ed3n \u0111i\u1ec7n \u1ed5n \u0111\u1ecbnh, d\u1ea3i \u0111i\u1ec7n \u00e1p r\u1ed9ng, ti\u1ebft ki\u1ec7m n\u0103ng l\u01b0\u1ee3ng v\u00e0 d\u1ec5 v\u1eadn h\u00e0nh.<\/figcaption><\/figure>","protected":false},"excerpt":{"rendered":"<p>DAXIN ENERGY EX3C3 100kVA three-phase online UPS provides 100kW true double-conversion backup power for data centers, telecom facilities, industrial equipment and commercial buildings. It features high efficiency, wide input voltage range, 0ms transfer time, generator compatibility and optional SNMP remote monitoring.<\/p>","protected":false},"featured_media":4089,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[98,104],"product_tag":[],"class_list":["post-2314","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-high-frequency-ups","product_cat-hf-3-3-phase-ups","first","instock","downloadable","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product\/2314","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/comments?post=2314"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media\/4089"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media?parent=2314"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_brand?post=2314"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_cat?post=2314"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_tag?post=2314"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}