{"id":2308,"date":"2026-07-17T11:39:52","date_gmt":"2026-07-17T11:39:52","guid":{"rendered":"https:\/\/btrytech.com\/?post_type=product&#038;p=2308"},"modified":"2026-07-17T11:44:33","modified_gmt":"2026-07-17T11:44:33","slug":"ex3c3-ups-ba-pha-truc-tuyen-80-kva","status":"publish","type":"product","link":"https:\/\/btrytech.com\/vi\/product\/ex3c3-80kva-three-phase-online-ups\/","title":{"rendered":"B\u1ed9 l\u01b0u \u0111i\u1ec7n tr\u1ef1c tuy\u1ebfn ba pha | B\u1ed9 l\u01b0u \u0111i\u1ec7n c\u00f4ng nghi\u1ec7p EX3C3 80kVA | DAXIN ENERGY"},"content":{"rendered":"<h1 class=\"cpcc-ts-01-right-tit\" title=\"EX3C3 80kVA\">EX3C3 80kVA Three Phase Online UPS Features<\/h1>\n<h2 data-section-id=\"1baxbse\" data-start=\"272\" data-end=\"304\">High Reliability Architecture<\/h2>\n<p data-start=\"306\" data-end=\"616\">The DAXIN ENERGY EX3C3 Series Three Phase Online UPS adopts advanced double-conversion online topology to deliver stable, uninterrupted and clean sine wave power for mission-critical applications. It effectively isolates connected equipment from utility disturbances, voltage fluctuations and electrical noise.<\/p>\n<h3 data-section-id=\"1iz91iu\" data-start=\"618\" data-end=\"634\">C\u00e1c t\u00ednh n\u0103ng ch\u00ednh<\/h3>\n<p data-start=\"636\" data-end=\"678\">\u2714 True Online Double Conversion Technology<\/p>\n<p data-start=\"680\" data-end=\"798\">Provides continuous pure sine wave output with zero transfer time, ensuring maximum protection for critical equipment.<\/p>\n<p data-start=\"800\" data-end=\"830\">\u2714 Dual CPU Intelligent Control<\/p>\n<p data-start=\"832\" data-end=\"945\">Advanced modular dual-CPU architecture improves operational stability, system reliability and overall efficiency.<\/p>\n<p data-start=\"947\" data-end=\"977\">\u2714 Intelligent Battery Charging<\/p>\n<p data-start=\"979\" data-end=\"1133\">Smart charging management automatically adjusts charging current according to battery condition, extending battery life and improving charging efficiency.<\/p>\n<p data-start=\"1135\" data-end=\"1173\">\u2714 Active Power Factor Correction (PFC)<\/p>\n<p data-start=\"1175\" data-end=\"1269\">Input power factor up to 0.99 minimizes harmonic pollution and improves overall power quality.<\/p>\n<p data-start=\"1271\" data-end=\"1297\">\u2714 Wide Input Voltage Range<\/p>\n<p data-start=\"1299\" data-end=\"1451\">Supports unstable utility power environments with an extra-wide AC input range, reducing battery discharge frequency and increasing system availability.<\/p>\n<p data-start=\"1453\" data-end=\"1475\">\u2714 Generator Compatible<\/p>\n<p data-start=\"1477\" data-end=\"1619\">Advanced synchronization technology significantly reduces generator capacity requirements and ensures smooth operation with diesel generators.<\/p>\n<p data-start=\"1621\" data-end=\"1646\">\u2714 Low Harmonic Distortion<\/p>\n<p data-start=\"1648\" data-end=\"1753\">Integrated harmonic filters minimize interference to the utility grid and connected electrical equipment.<\/p>\n<p data-start=\"1755\" data-end=\"1774\">\u2714 DC Start Function<\/p>\n<p data-start=\"1776\" data-end=\"1880\">Allows UPS startup directly from batteries without utility power, ensuring emergency power availability.<\/p>\n<hr data-start=\"1882\" data-end=\"1885\" \/>\n<h1 data-section-id=\"1um7y15\" data-start=\"1887\" data-end=\"1913\">Comprehensive Protection<\/h1>\n<p data-start=\"1915\" data-end=\"2019\">The EX3C3 Series incorporates multiple intelligent protection mechanisms to maximize operational safety.<\/p>\n<p data-start=\"2021\" data-end=\"2041\">Protection Functions<\/p>\n<ul data-start=\"2043\" data-end=\"2293\">\n<li data-section-id=\"1iqdzq4\" data-start=\"2043\" data-end=\"2071\">Output Overload Protection<\/li>\n<li data-section-id=\"1ok8t3p\" data-start=\"2072\" data-end=\"2105\">Output Short Circuit Protection<\/li>\n<li data-section-id=\"jpgwks\" data-start=\"2106\" data-end=\"2144\">Inverter Over Temperature Protection<\/li>\n<li data-section-id=\"x7la49\" data-start=\"2145\" data-end=\"2174\">Battery Low Voltage Warning<\/li>\n<li data-section-id=\"1yq6bte\" data-start=\"2175\" data-end=\"2206\">Battery Overcharge Protection<\/li>\n<li data-section-id=\"7nj5c6\" data-start=\"2207\" data-end=\"2236\">Intelligent Fault Diagnosis<\/li>\n<li data-section-id=\"1fhv44t\" data-start=\"2237\" data-end=\"2265\">Automatic Bypass Switching<\/li>\n<li data-section-id=\"1gtz7l1\" data-start=\"2266\" data-end=\"2293\">Manual Maintenance Bypass<\/li>\n<\/ul>\n<p data-start=\"2295\" data-end=\"2402\">The built-in maintenance bypass enables uninterrupted load operation during servicing, minimizing downtime.<\/p>\n<hr data-start=\"2404\" data-end=\"2407\" \/>\n<h1 data-section-id=\"1lth6bq\" data-start=\"2409\" data-end=\"2437\">Intelligent LCD Monitoring<\/h1>\n<p data-start=\"2439\" data-end=\"2492\">A large LCD display provides real-time monitoring of:<\/p>\n<ul data-start=\"2494\" data-end=\"2618\">\n<li data-section-id=\"1cza5q4\" data-start=\"2494\" data-end=\"2509\">\u0110i\u1ec7n \u00e1p \u0111\u1ea7u v\u00e0o<\/li>\n<li data-section-id=\"137h5px\" data-start=\"2510\" data-end=\"2526\">\u0110i\u1ec7n \u00e1p \u0111\u1ea7u ra<\/li>\n<li data-section-id=\"qg6ic1\" data-start=\"2527\" data-end=\"2543\">T\u00ecnh tr\u1ea1ng pin<\/li>\n<li data-section-id=\"czg46u\" data-start=\"2544\" data-end=\"2561\">Load Percentage<\/li>\n<li data-section-id=\"15o3svq\" data-start=\"2562\" data-end=\"2578\">Operating Mode<\/li>\n<li data-section-id=\"13dh1fb\" data-start=\"2579\" data-end=\"2598\">Alarm Information<\/li>\n<li data-section-id=\"mh0q9j\" data-start=\"2599\" data-end=\"2618\">System Parameters<\/li>\n<\/ul>\n<p data-start=\"2620\" data-end=\"2684\">This enables quick diagnostics and convenient daily maintenance.<\/p>\n<hr data-start=\"2686\" data-end=\"2689\" \/>\n<h1 data-section-id=\"16nrg3v\" data-start=\"2691\" data-end=\"2711\">Network Management<\/h1>\n<p data-start=\"2713\" data-end=\"2787\">Multiple communication interfaces provide comprehensive remote monitoring.<\/p>\n<p data-start=\"2789\" data-end=\"2809\">Supported Interfaces<\/p>\n<ul data-start=\"2811\" data-end=\"2878\">\n<li data-section-id=\"179pdei\" data-start=\"2811\" data-end=\"2818\">RS232<\/li>\n<li data-section-id=\"179pf00\" data-start=\"2819\" data-end=\"2826\">RS485<\/li>\n<li data-section-id=\"1sxaflz\" data-start=\"2827\" data-end=\"2844\">SNMP (Optional)<\/li>\n<li data-section-id=\"1ss18lo\" data-start=\"2845\" data-end=\"2878\">Intelligent Monitoring Software<\/li>\n<\/ul>\n<p data-start=\"2880\" data-end=\"2979\">Remote monitoring enables users to supervise UPS performance from anywhere through LAN or Internet.<\/p>\n<hr data-start=\"2981\" data-end=\"2984\" \/>\n<h1 data-section-id=\"1ot91dh\" data-start=\"2986\" data-end=\"3028\">Optional Smart Battery Monitoring System<\/h1>\n<p data-start=\"3030\" data-end=\"3067\">Optional battery monitoring supports:<\/p>\n<ul data-start=\"3069\" data-end=\"3258\">\n<li data-section-id=\"m5ylt6\" data-start=\"3069\" data-end=\"3104\">Individual Cell Voltage Detection<\/li>\n<li data-section-id=\"18ri9qv\" data-start=\"3105\" data-end=\"3125\">Over Voltage Alarm<\/li>\n<li data-section-id=\"4kzy6p\" data-start=\"3126\" data-end=\"3147\">Under Voltage Alarm<\/li>\n<li data-section-id=\"imw1j3\" data-start=\"3148\" data-end=\"3170\">Cell Imbalance Alarm<\/li>\n<li data-section-id=\"dfygtz\" data-start=\"3171\" data-end=\"3208\">Real-time Battery Health Monitoring<\/li>\n<li data-section-id=\"1q7dt54\" data-start=\"3209\" data-end=\"3231\">Fault Identification<\/li>\n<li data-section-id=\"1lex7o8\" data-start=\"3232\" data-end=\"3258\">Maintenance Notification<\/li>\n<\/ul>\n<hr data-start=\"3260\" data-end=\"3263\" \/>\n<h1 data-section-id=\"1cupc6b\" data-start=\"3265\" data-end=\"3310\">Industrial-Grade Environmental Adaptability<\/h1>\n<p data-start=\"3312\" data-end=\"3425\">The control boards are protected with industrial-grade conformal coating, providing excellent resistance against:<\/p>\n<ul data-start=\"3427\" data-end=\"3483\">\n<li data-section-id=\"1j40wse\" data-start=\"3427\" data-end=\"3433\">Dust<\/li>\n<li data-section-id=\"fhxeyu\" data-start=\"3434\" data-end=\"3444\">Moisture<\/li>\n<li data-section-id=\"11rriz4\" data-start=\"3445\" data-end=\"3456\">Corrosion<\/li>\n<li data-section-id=\"4h0964\" data-start=\"3457\" data-end=\"3467\">Salt Fog<\/li>\n<li data-section-id=\"1jqqcf3\" data-start=\"3468\" data-end=\"3483\">High Humidity<\/li>\n<\/ul>\n<p data-start=\"3485\" data-end=\"3495\">Ideal for:<\/p>\n<ul data-start=\"3497\" data-end=\"3638\">\n<li data-section-id=\"1elqj0g\" data-start=\"3497\" data-end=\"3511\">Trung t\u00e2m d\u1eef li\u1ec7u<\/li>\n<li data-section-id=\"jna3n1\" data-start=\"3512\" data-end=\"3535\">Tr\u1ea1m g\u1ed1c vi\u1ec5n th\u00f4ng<\/li>\n<li data-section-id=\"1rcn5ob\" data-start=\"3536\" data-end=\"3555\">Industrial Plants<\/li>\n<li data-section-id=\"1k0ubkf\" data-start=\"3556\" data-end=\"3567\">B\u1ec7nh vi\u1ec7n<\/li>\n<li data-section-id=\"1g8mpg8\" data-start=\"3568\" data-end=\"3578\">Airports<\/li>\n<li data-section-id=\"1cvg7i1\" data-start=\"3579\" data-end=\"3593\">Rail Transit<\/li>\n<li data-section-id=\"1ht06xd\" data-start=\"3594\" data-end=\"3615\">Smart Manufacturing<\/li>\n<li data-section-id=\"14ndbl\" data-start=\"3616\" data-end=\"3638\">C\u00e1c t\u00f2a nh\u00e0 th\u01b0\u01a1ng m\u1ea1i<br \/>\n<strong><strong>Th\u00f4ng s\u1ed1 k\u1ef9 thu\u1eadt<br \/>\n<\/strong><\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>M\u1eb7t h\u00e0ng<\/th>\n<th align=\"right\">EX3C3-10kVA<\/th>\n<th align=\"right\">EX3C3-20 kVA<\/th>\n<th align=\"right\">EX3C3-30 kVA<\/th>\n<th align=\"right\">EX3C3-40 kVA<\/th>\n<th align=\"right\">EX3C3-60 kVA<\/th>\n<th align=\"right\">EX3C3-80 kVA<\/th>\n<th align=\"right\">EX3C3-100kVA<\/th>\n<th align=\"right\">EX3C3-120 kVA<\/th>\n<th align=\"right\">EX3C3-180 kVA<\/th>\n<th align=\"right\">EX3C3-200 kVA<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>C\u00f4ng su\u1ea5t<\/td>\n<td align=\"right\">10 kVA\/9 kW<\/td>\n<td align=\"right\">20 kVA\/18 kW<\/td>\n<td align=\"right\">30 kVA\/30 kW<\/td>\n<td align=\"right\">40 kVA\/40 kW<\/td>\n<td align=\"right\">60 kVA\/60 kW<\/td>\n<td align=\"right\">80 kVA\/80 kW<\/td>\n<td align=\"right\">100 kVA\/100 kW<\/td>\n<td align=\"right\">120 kVA\/120 kW<\/td>\n<td align=\"right\">180 kVA\/180 kW<\/td>\n<td align=\"right\">200 kVA\/200 kW<\/td>\n<\/tr>\n<tr>\n<td>Giai \u0111o\u1ea1n nh\u1eadp li\u1ec7u<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<td align=\"right\">Three Phase + Neutral<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec7n \u00e1p \u0111\u1ea7u v\u00e0o<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<\/tr>\n<tr>\n<td>T\u1ea7n s\u1ed1 \u0111\u1ea7u v\u00e0o<\/td>\n<td align=\"right\">45\u201355Hz \/ 55\u201365Hz<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">50\/60Hz Auto<\/td>\n<td align=\"right\">50\/60Hz Auto<\/td>\n<td align=\"right\">50\/60Hz Auto<\/td>\n<td align=\"right\">50\/60Hz Auto<\/td>\n<\/tr>\n<tr>\n<td>H\u1ec7 s\u1ed1 c\u00f4ng su\u1ea5t \u0111\u1ea7u v\u00e0o<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<td align=\"right\">\u22650.99<\/td>\n<\/tr>\n<tr>\n<td>\u0110i\u1ec7n \u00e1p \u0111\u1ea7u ra<\/td>\n<td align=\"right\">380\/400\/415VAC<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<\/tr>\n<tr>\n<td>T\u1ea7n s\u1ed1 \u0111\u1ea7u ra<\/td>\n<td align=\"right\">50\/60Hz<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<\/tr>\n<tr>\n<td>THD<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<td align=\"right\">\u22641% Linear Load<\/td>\n<\/tr>\n<tr>\n<td>Hi\u1ec7u qu\u1ea3<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<td align=\"right\">Up to 96.5%<\/td>\n<\/tr>\n<tr>\n<td>Giao ti\u1ebfp<\/td>\n<td align=\"right\">RS232 \/ RS485 \/ SNMP (Optional)<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<\/tr>\n<tr>\n<td>Nhi\u1ec7t \u0111\u1ed9 ho\u1ea1t \u0111\u1ed9ng<\/td>\n<td align=\"right\">0\u201340\u00b0C<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<td align=\"right\">Same<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/li>\n<\/ul>\n<h2 data-section-id=\"1r8frcv\" data-start=\"2620\" data-end=\"2649\">Frequently Asked Questions<\/h2>\n<h3 data-section-id=\"1wg494g\" data-start=\"2651\" data-end=\"2688\">What is a Three Phase Online UPS?<\/h3>\n<p data-start=\"2690\" data-end=\"2834\">A Three Phase Online UPS continuously converts AC power to DC and back to AC, providing clean and uninterrupted power for critical applications.<\/p>\n<hr data-start=\"2836\" data-end=\"2839\" \/>\n<h3 data-section-id=\"1fcwcmj\" data-start=\"2841\" data-end=\"2891\">Where are Three Phase Online UPS systems used?<\/h3>\n<p data-start=\"2893\" data-end=\"2917\">They are widely used in:<\/p>\n<ul data-start=\"2919\" data-end=\"3039\">\n<li data-section-id=\"1elqj0g\" data-start=\"2919\" data-end=\"2933\">Trung t\u00e2m d\u1eef li\u1ec7u<\/li>\n<li data-section-id=\"jna3n1\" data-start=\"2934\" data-end=\"2957\">Tr\u1ea1m g\u1ed1c vi\u1ec5n th\u00f4ng<\/li>\n<li data-section-id=\"1k0ubkf\" data-start=\"2958\" data-end=\"2969\">B\u1ec7nh vi\u1ec7n<\/li>\n<li data-section-id=\"17og4a8\" data-start=\"2970\" data-end=\"2993\">Industrial Automation<\/li>\n<li data-section-id=\"1982k8s\" data-start=\"2994\" data-end=\"3016\">C\u00e1c nh\u00e0 m\u00e1y s\u1ea3n xu\u1ea5t<\/li>\n<li data-section-id=\"14ndbl\" data-start=\"3017\" data-end=\"3039\">C\u00e1c t\u00f2a nh\u00e0 th\u01b0\u01a1ng m\u1ea1i<\/li>\n<\/ul>\n<hr data-start=\"3041\" data-end=\"3044\" \/>\n<h3 data-section-id=\"h7e9ql\" data-start=\"3046\" data-end=\"3090\">Why choose DAXIN ENERGY Three Phase UPS?<\/h3>\n<p data-start=\"3092\" data-end=\"3122\">Because DAXIN ENERGY provides:<\/p>\n<ul data-start=\"3124\" data-end=\"3265\">\n<li data-section-id=\"kmgp98\" data-start=\"3124\" data-end=\"3155\">True Online Double Conversion<\/li>\n<li data-section-id=\"17schr2\" data-start=\"3156\" data-end=\"3185\">High Efficiency up to 96.5%<\/li>\n<li data-section-id=\"akwkun\" data-start=\"3186\" data-end=\"3211\">Intelligent DSP Control<\/li>\n<li data-section-id=\"1mr8fze\" data-start=\"3212\" data-end=\"3238\">Optional SNMP Monitoring<\/li>\n<li data-section-id=\"10i82tn\" data-start=\"3239\" data-end=\"3265\">Global OEM &amp; ODM Support<\/li>\n<\/ul>\n<figure id=\"attachment_2232\" aria-describedby=\"caption-attachment-2232\" style=\"width: 982px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2232\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/ups-power-solution-provider-english.png\" alt=\"C\u00e1c t\u00ednh n\u0103ng ch\u00ednh c\u1ee7a b\u1ed9 l\u01b0u \u0111i\u1ec7n tr\u1ef1c tuy\u1ebfn (UPS) DAXIN ENERGY bao g\u1ed3m ngu\u1ed3n \u0111i\u1ec7n \u1ed5n \u0111\u1ecbnh, d\u1ea3i \u0111i\u1ec7n \u00e1p r\u1ed9ng, ti\u1ebft ki\u1ec7m n\u0103ng l\u01b0\u1ee3ng v\u00e0 d\u1ec5 v\u1eadn h\u00e0nh\" width=\"982\" height=\"664\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/ups-power-solution-provider-english.png 982w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/ups-power-solution-provider-english-300x203.png 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/ups-power-solution-provider-english-768x519.png 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/ups-power-solution-provider-english-18x12.png 18w\" sizes=\"auto, (max-width: 982px) 100vw, 982px\" \/><figcaption id=\"caption-attachment-2232\" class=\"wp-caption-text\">C\u00e1c t\u00ednh n\u0103ng n\u1ed5i b\u1eadt c\u1ee7a b\u1ed9 l\u01b0u \u0111i\u1ec7n tr\u1ef1c tuy\u1ebfn (UPS) DAXIN ENERGY, bao g\u1ed3m ngu\u1ed3n \u0111i\u1ec7n \u1ed5n \u0111\u1ecbnh, d\u1ea3i \u0111i\u1ec7n \u00e1p r\u1ed9ng, ti\u1ebft ki\u1ec7m n\u0103ng l\u01b0\u1ee3ng v\u00e0 d\u1ec5 v\u1eadn h\u00e0nh.<\/figcaption><\/figure>","protected":false},"excerpt":{"rendered":"<p><strong>DAXIN ENERGY EX3C3 Three Phase Online UPS<\/strong> delivers true online double conversion technology for continuous and reliable power protection. Designed for data centers, telecom networks, industrial automation, healthcare facilities and commercial buildings, the EX3C3 Series provides pure sine wave output, intelligent DSP control, high efficiency up to 96.5%, generator compatibility and advanced battery management.<\/p>\n<ul>\n<li>\u2714 True Online Double Conversion UPS<\/li>\n<li>\u2714 Capacity: 10kVA\u2013200kVA<\/li>\n<li>\u2714 Three Phase Input \/ Output<\/li>\n<li>\u2714 DSP Intelligent Control<\/li>\n<li>\u2714 Pure Sine Wave Output<\/li>\n<li>\u2714 High Efficiency up to 96.5%<\/li>\n<li>\u2714 Optional SNMP Remote Monitoring<\/li>\n<li>\u2714 Industrial &amp; Data Center Applications<\/li>\n<\/ul>","protected":false},"featured_media":2311,"comment_status":"open","ping_status":"closed","template":"","meta":{"_crdt_document":""},"product_brand":[622,46],"product_cat":[98,104],"product_tag":[],"class_list":["post-2308","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-high-frequency-ups","product_cat-hf-3-3-phase-ups","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product\/2308","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/comments?post=2308"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media\/2311"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/media?parent=2308"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_brand?post=2308"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_cat?post=2308"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/vi\/wp-json\/wp\/v2\/product_tag?post=2308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}