{"id":3015,"date":"2026-08-02T15:28:12","date_gmt":"2026-08-02T15:28:12","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=3015"},"modified":"2026-08-17T17:17:25","modified_gmt":"2026-08-17T09:17:25","slug":"daxin-rm33-200kva-system-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/tr\/product\/daxin-rm33-200kva-system-ups\/","title":{"rendered":"200 kVA Mod\u00fcler \u00c7evrimi\u00e7i UPS | DAXIN RM33"},"content":{"rendered":"<h2>What Is the DAXIN RM33 200kVA Modular Online UPS?<\/h2>\n<p>The DAXIN RM33 200kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.<\/p>\n<p>Its modular cabinet architecture integrates power modules, system control, protection and service access within a scalable UPS platform. The reference configuration provides 200kW cabinet capacity and supports external battery packs for project-specific backup requirements.<\/p>\n<p>The RM33 series supports 3 \u00d7 380\/400\/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.<\/p>\n<p>Final installed capacity, power-module configuration, battery runtime, redundancy architecture, communications and project accessories should be confirmed against the approved DAXIN technical proposal.<\/p>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>RM33-200kVA<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Model<\/td>\n<td><strong>RM33-200kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>UPS T\u00fcr\u00fc<\/td>\n<td>Mod\u00fcler \u00c7evrimi\u00e7i UPS<\/td>\n<\/tr>\n<tr>\n<td>A\u015fama<\/td>\n<td>\u00dc\u00e7 Fazl\u0131 Giri\u015f \/ \u00dc\u00e7 Fazl\u0131 \u00c7\u0131k\u0131\u015f<\/td>\n<\/tr>\n<tr>\n<td>Dolap Kapasitesi<\/td>\n<td><strong>200kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Pil T\u00fcr\u00fc<\/td>\n<td>Harici Pil Paketi<\/td>\n<\/tr>\n<tr>\n<td>Pil Dolab\u0131 Kapasitesi<\/td>\n<td>20kVA \/ 20kW<\/td>\n<\/tr>\n<tr>\n<td>\u0130ste\u011fe Ba\u011fl\u0131 Pil Dolaplar\u0131<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Giri\u015f Gerilimi<\/td>\n<td>3 \u00d7 380\/400\/415 VAC (3 faz + N)<\/td>\n<\/tr>\n<tr>\n<td>Giri\u015f Frekans\u0131<\/td>\n<td>50\/60 Hz Otomatik Alg\u0131lama<\/td>\n<\/tr>\n<tr>\n<td>Giri\u015f Frekans Aral\u0131\u011f\u0131<\/td>\n<td>40\u201370 Hz<\/td>\n<\/tr>\n<tr>\n<td>Giri\u015f G\u00fc\u00e7 Fakt\u00f6r\u00fc<\/td>\n<td>\u22650,99 @ 100% Y\u00fck<\/td>\n<\/tr>\n<tr>\n<td>Giri\u015f Ak\u0131m\u0131 THDi<\/td>\n<td>&lt;2% @ 100% Y\u00fck<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015f Gerilimi<\/td>\n<td>3 \u00d7 380\/400\/415 VAC (3 faz + N)<\/td>\n<\/tr>\n<tr>\n<td>Statik Gerilim Kararl\u0131l\u0131\u011f\u0131<\/td>\n<td>\u2264\u00b10,31 TP3T Tipik Y\u00fck<\/td>\n<\/tr>\n<tr>\n<td>Dinamik Gerilim Kararl\u0131l\u0131\u011f\u0131<\/td>\n<td>\u2264\u00b13% Tipik Y\u00fck<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015f Frekans\u0131<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>\u00c7\u0131k\u0131\u015f THD'si<\/td>\n<td>\u22641% Do\u011frusal \/ \u22642% Do\u011frusal Olmayan<\/td>\n<\/tr>\n<tr>\n<td>Verimlilik<\/td>\n<td><strong>En fazla 96,51 TP3T<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Boyutlar<\/td>\n<td><strong>1100 \u00d7 600 \u00d7 2010mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Net A\u011f\u0131rl\u0131k<\/td>\n<td><strong>282kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>\u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131<\/td>\n<td>0\u201340 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Rak\u0131m<\/td>\n<td>&lt;1000m Rated Power<\/td>\n<\/tr>\n<tr>\n<td>Koruma S\u0131n\u0131f\u0131<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>\u0130leti\u015fim<\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td>A\u011f Y\u00f6netimi<\/td>\n<td>\u0130ste\u011fe ba\u011fl\u0131 SNMP<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4939\" aria-describedby=\"caption-attachment-4939\" style=\"width: 812px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4939\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp\" alt=\"DAXIN RM33 Modular Online UPS Technical Specifications\" width=\"812\" height=\"1935\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp 812w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-126x300.webp 126w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-430x1024.webp 430w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-768x1830.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-645x1536.webp 645w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-5x12.webp 5w\" sizes=\"auto, (max-width: 812px) 100vw, 812px\" \/><figcaption id=\"caption-attachment-4939\" class=\"wp-caption-text\">Technical specifications for the DAXIN RM33 three-phase modular online UPS series.<\/figcaption><\/figure><figcaption>Product View for DAXIN RM33-200kVA Modular UPS System Cabinet.<\/figcaption><\/figure>\n<h2>Ba\u015fl\u0131ca Avantajlar<\/h2>\n<ul>\n<li><strong>\u00d6l\u00e7eklenebilir Mod\u00fcler Mimari:<\/strong>\u00a0Modular UPS design supports flexible capacity planning and future system expansion.<\/li>\n<li><strong>200kW Cabinet Capacity:<\/strong>\u00a0The RM33-200kVA reference cabinet is designed for large three-phase critical-power applications.<\/li>\n<li><strong>\u00dc\u00e7 Fazl\u0131 G\u00fc\u00e7 Korumas\u0131:<\/strong>\u00a0Supports 3 \u00d7 380\/400\/415VAC three-phase input and output for data center, telecom and industrial electrical systems.<\/li>\n<li><strong>D\u00fc\u015f\u00fck Giri\u015f Harmonik Bozulmas\u0131:<\/strong>\u00a0Tam y\u00fckte 2%\u2019nin alt\u0131ndaki giri\u015f ak\u0131m\u0131 THDi de\u011feri, yukar\u0131 ak\u0131\u015ftaki elektriksel etkiyi azaltmaya yard\u0131mc\u0131 olur.<\/li>\n<li><strong>Y\u00fcksek Giri\u015f G\u00fc\u00e7 Katsay\u0131s\u0131:<\/strong>\u00a0100% y\u00fck\u00fcnde giri\u015f g\u00fc\u00e7 fakt\u00f6r\u00fc en az 0,99\u2019dur.<\/li>\n<li><strong>Y\u00fcksek Verimlilik:<\/strong>\u00a0Sistem verimlili\u011fi 96,51 TP3T\u2019ye kadar belirtilmi\u015ftir.<\/li>\n<li><strong>External Battery Configuration:<\/strong>\u00a0Battery systems can be engineered according to required backup runtime and project requirements.<\/li>\n<li><strong>Uzaktan \u0130zleme:<\/strong>\u00a0RS-232\/USB ileti\u015fimi desteklenmektedir; iste\u011fe ba\u011fl\u0131 SNMP a\u011f y\u00f6netimi de mevcuttur.<\/li>\n<\/ul>\n<h2><\/h2>\n<h2>Mod\u00fcler UPS Sistemi Nedir?<\/h2>\n<p>A modular UPS system uses multiple power modules within a common cabinet architecture instead of relying on a single fixed-capacity power stage.<\/p>\n<p>This approach allows UPS capacity, maintenance strategy and redundancy architecture to be planned according to the critical load and future expansion requirements.<\/p>\n<p>The DAXIN RM33 series combines modular power architecture with centralized control, external battery systems and network-management options for scalable critical-power applications.<\/p>\n<h2>Why Choose a 200kVA Modular UPS for a Data Center?<\/h2>\n<p>A modular UPS can help data center operators align installed power capacity with the actual critical load while preserving a path for future expansion and redundancy planning.<\/p>\n<p>The DAXIN RM33-200kVA combines three-phase online power protection, modular system architecture, external battery configuration and optional network monitoring for data center and mission-critical infrastructure applications.<\/p>\n<p>Final system sizing should consider the IT load in kW and kVA, power factor, redundancy target, expected expansion, required battery autonomy and upstream electrical architecture.<\/p>\n<h2>Tipik Uygulamalar<\/h2>\n<ul>\n<li>Veri merkezleri ve sunucu odalar\u0131<\/li>\n<li>Telekom \u00e7ekirdek tesisleri ve a\u011f altyap\u0131s\u0131<\/li>\n<li>End\u00fcstriyel otomasyon ve \u00fcretim tesisleri<\/li>\n<li>Finans ve bankac\u0131l\u0131k hizmetleri<\/li>\n<li>Sa\u011fl\u0131k hizmetleri ve t\u0131bbi altyap\u0131<\/li>\n<li>Ula\u015f\u0131m ve kamu altyap\u0131s\u0131<\/li>\n<li>Kurumsal BT tesisleri<\/li>\n<li>Di\u011fer \u00f6l\u00e7eklenebilir, g\u00f6rev a\u00e7\u0131s\u0131ndan kritik g\u00fc\u00e7 sistemleri<\/li>\n<\/ul>\n<h2>Se\u00e7im ve Proje Planlamas\u0131<\/h2>\n<p>Sipari\u015f vermeden \u00f6nce, se\u00e7ilen modele ve proje \u00e7izimlerine g\u00f6re tam g\u00fc\u00e7 de\u011ferini, giri\u015f\/\u00e7\u0131k\u0131\u015f faz\u0131n\u0131, gerilimi, frekans\u0131, g\u00fc\u00e7 fakt\u00f6r\u00fcn\u00fc, ak\u00fc gerilimini, \u00e7al\u0131\u015fma s\u00fcresini, baypas \u00f6zelli\u011fini, ileti\u015fim \u00f6zelliklerini, boyutlar\u0131, \u00e7evresel s\u0131n\u0131rlar\u0131 ve kurulum y\u00f6ntemini teyit ediniz.<\/p>\n<h2>S\u0131k Sorulan Sorular<\/h2>\n<h3>Bu \u00fcr\u00fcn belirli bir projeye g\u00f6re \u00f6zelle\u015ftirilebilir mi?<\/h3>\n<p>Evet. Elektrik konfig\u00fcrasyonu, pil \u00e7al\u0131\u015fma s\u00fcresi, ileti\u015fim, baypas, kabin d\u00fczeni ve proje aksesuarlar\u0131, tesisin gereksinimlerine g\u00f6re g\u00f6zden ge\u00e7irilebilir.<\/p>\n<h3>T\u00fcm teknik derecelendirmeler serinin tamam\u0131nda ortak m\u0131d\u0131r?<\/h3>\n<p>Hay\u0131r. Teknik \u00f6zellikler ve i\u015flevler modele ve yap\u0131land\u0131rmaya g\u00f6re de\u011fi\u015fiklik g\u00f6sterir. Nihai referans olarak projeye \u00f6zg\u00fc teknik veri sayfas\u0131n\u0131 kullan\u0131n.<\/p>\n<h3>DAXIN ENERGY, sistem se\u00e7iminde destek sa\u011flayabilir mi?<\/h3>\n<p>Evet. Y\u00fck listesini, faz ve gerilimi, gerekli \u00e7al\u0131\u015fma s\u00fcresini, yedeklilik hedefini, ileti\u015fim gereksinimlerini ve kurulum ortam\u0131n\u0131 belirtin.<\/p>\n<h2>Proje Yap\u0131land\u0131rmas\u0131 Talep Et<\/h2>\n<p>\u00d6zel olarak haz\u0131rlanm\u0131\u015f bir UPS veya ak\u00fc teklifi almak i\u00e7in y\u00fck verilerini, tek hat \u015femas\u0131n\u0131, gerekli yedekleme s\u00fcresini ve saha ko\u015fullar\u0131n\u0131 bize g\u00f6nderin.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"5difiu\" data-start=\"8307\" data-end=\"8341\">What is the DAXIN RM33-200kVA?<\/h3>\n<blockquote data-start=\"8343\" data-end=\"8460\">\n<p data-start=\"8345\" data-end=\"8460\">The DAXIN RM33-200kVA is a three-phase modular online UPS system designed for scalable critical-power applications.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"152my1e\" data-start=\"8462\" data-end=\"8495\">What is the cabinet capacity?<\/h3>\n<blockquote data-start=\"8497\" data-end=\"8601\">\n<p data-start=\"8499\" data-end=\"8601\">The supplied RM33 series specification lists 200kW cabinet capacity for the RM33-200kVA configuration.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"zp921o\" data-start=\"8603\" data-end=\"8653\">Hangi giri\u015f ve \u00e7\u0131k\u0131\u015f gerilimlerini destekliyor?<\/h3>\n<blockquote data-start=\"8655\" data-end=\"8739\">\n<p data-start=\"8657\" data-end=\"8739\">Referans teknik \u00f6zellik belgesinde 3 \u00d7 380\/400\/415 VAC \u00fc\u00e7 fazl\u0131 giri\u015f ve \u00e7\u0131k\u0131\u015f de\u011ferleri belirtilmi\u015ftir.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"18hlpeq\" data-start=\"8741\" data-end=\"8786\">Giri\u015f g\u00fc\u00e7 fakt\u00f6r\u00fc ve THDi de\u011ferleri nedir?<\/h3>\n<blockquote data-start=\"8788\" data-end=\"8908\">\n<p data-start=\"8790\" data-end=\"8908\">Referans teknik \u00f6zelliklerinde, tam y\u00fckte en az 0,99 giri\u015f g\u00fc\u00e7 fakt\u00f6r\u00fc ve 2%\u2019nin alt\u0131nda bir giri\u015f ak\u0131m\u0131 THDi de\u011feri belirtilmi\u015ftir.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"1xhhnr9\" data-start=\"8910\" data-end=\"8954\">RM33, uzaktan izleme \u00f6zelli\u011fini destekliyor mu?<\/h3>\n<blockquote data-start=\"8956\" data-end=\"9056\">\n<p data-start=\"8958\" data-end=\"9056\">Yes. RS-232\/USB communication is supported, and SNMP network management is available as an option.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"16gc40b\" data-start=\"9058\" data-end=\"9110\">How should the RM33-200kVA system be configured?<\/h3>\n<blockquote data-start=\"9112\" data-end=\"9306\">\n<p data-start=\"9114\" data-end=\"9306\">Final configuration should consider the critical load, required redundancy, future expansion, battery runtime, electrical distribution, communication requirements and installation environment.<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p>The DAXIN RM33 200kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom and industrial facilities. Its modular architecture supports flexible capacity planning, centralized control, external battery configurations and optional SNMP monitoring, with efficiency up to 96.5%.<\/p>","protected":false},"featured_media":4936,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,100],"product_tag":[],"class_list":["post-3015","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-ups-system-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product\/3015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/comments?post=3015"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/media\/4936"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/media?parent=3015"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product_brand?post=3015"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product_cat?post=3015"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product_tag?post=3015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}