{"id":2903,"date":"2026-08-02T15:16:28","date_gmt":"2026-08-02T15:16:28","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=2903"},"modified":"2026-08-14T22:02:05","modified_gmt":"2026-08-14T14:02:05","slug":"60-kva-uc-fazli-cevrimici-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/tr\/product\/60kva-three-phase-online-ups\/","title":{"rendered":"DAXIN HR33-60KL 60 kVA \u00dc\u00e7 Fazl\u0131 \u00c7evrimi\u00e7i UPS"},"content":{"rendered":"<h3>DAXIN HR33-60KL 60 kVA \u00dc\u00e7 Fazl\u0131 \u00c7evrimi\u00e7i UPS Nedir?<\/h3>\n<p>DAXIN HR33-60KL, veri merkezleri, telekom tesisleri, sunucu odalar\u0131 ve di\u011fer g\u00f6rev a\u00e7\u0131s\u0131ndan kritik elektrik y\u00fckleri i\u00e7in kesintisiz g\u00fc\u00e7 korumas\u0131 sa\u011flamak \u00fczere tasarlanm\u0131\u015f, 60 kVA\/60 kW g\u00fcc\u00fcnde \u00fc\u00e7 fazl\u0131, y\u00fcksek frekansl\u0131 bir \u00e7evrimi\u00e7i UPS\u2019tir. Bu \u00fcr\u00fcn, zorlu kritik g\u00fc\u00e7 uygulamalar\u0131 i\u00e7in \u00e7evrimi\u00e7i g\u00fc\u00e7 d\u00f6n\u00fc\u015f\u00fcm\u00fc, y\u00fcksek giri\u015f g\u00fc\u00e7 fakt\u00f6r\u00fc, d\u00fc\u015f\u00fck \u00e7\u0131k\u0131\u015f harmonik bozulmas\u0131 ve yap\u0131land\u0131r\u0131labilir pil deste\u011fini bir araya getirir.<\/p>\n<h3>Ba\u015fl\u0131ca Avantajlar<\/h3>\n<ul>\n<li data-section-id=\"1wz3tw7\" data-start=\"2953\" data-end=\"3026\"><strong data-start=\"2955\" data-end=\"3026\">Zorlu kritik y\u00fck uygulamalar\u0131 i\u00e7in 60 kVA\/60 kW g\u00fc\u00e7 kapasitesi.<\/strong><\/li>\n<li data-section-id=\"1j953ye\" data-start=\"3027\" data-end=\"3146\"><strong data-start=\"3029\" data-end=\"3146\">\u00dc\u00e7 fazl\u0131 giri\u015f ve \u00fc\u00e7 fazl\u0131 \u00e7\u0131k\u0131\u015f mimarisi, veri merkezi, telekom ve end\u00fcstriyel g\u00fc\u00e7 sistemlerini destekler.<\/strong><\/li>\n<li data-section-id=\"1juw46k\" data-start=\"3147\" data-end=\"3251\"><strong data-start=\"3149\" data-end=\"3251\">\u00c7evrimi\u00e7i g\u00fc\u00e7 d\u00f6n\u00fc\u015ft\u00fcrme mimarisi, kritik ekipmanlara kesintisiz ve d\u00fczeltilmi\u015f g\u00fc\u00e7 sa\u011flar.<\/strong><\/li>\n<li data-section-id=\"1d0yywu\" data-start=\"3252\" data-end=\"3345\"><strong data-start=\"3254\" data-end=\"3345\">100% y\u00fck\u00fcnde \u22650,99 de\u011ferindeki giri\u015f g\u00fc\u00e7 fakt\u00f6r\u00fc, yukar\u0131 ak\u0131\u015fta verimli g\u00fc\u00e7 kullan\u0131m\u0131n\u0131 destekler.<\/strong><\/li>\n<li data-section-id=\"1mo1lla\" data-start=\"3346\" data-end=\"3434\"><strong data-start=\"3348\" data-end=\"3434\">Teknik \u00f6zellik belgesine g\u00f6re AC modunda verimlilik ,5%\u2019ye kadar \u00e7\u0131kmaktad\u0131r.<\/strong><\/li>\n<li data-section-id=\"1obqo3\" data-start=\"3435\" data-end=\"3534\"><strong data-start=\"3437\" data-end=\"3534\">RS-232\/USB ileti\u015fim aray\u00fczleri ve iste\u011fe ba\u011fl\u0131 SNMP deste\u011fi, hem yerel hem de a\u011f tabanl\u0131 g\u00fc\u00e7 y\u00f6netimini sa\u011flar.<\/strong><\/li>\n<li data-section-id=\"kmlmcl\" data-start=\"3535\" data-end=\"3633\"><strong data-start=\"3537\" data-end=\"3633\">Yap\u0131land\u0131r\u0131labilir pil ve \u015farj se\u00e7enekleri, projeye \u00f6zg\u00fc yedekleme s\u00fcresi gereksinimlerini kar\u015f\u0131lar.<\/strong><\/li>\n<\/ul>\n<h3>Teknik \u00d6zellikler<br \/>\nDAXIN HR33-60KL Teknik \u00d6zellikleri<\/h3>\n<table>\n<thead>\n<tr>\n<th>Parametre<\/th>\n<th>HR33-60KL<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Nominal Kapasite<\/strong><\/td>\n<td>60 kVA \/ 60 kW<\/td>\n<\/tr>\n<tr>\n<td><strong>A\u015fama Yap\u0131land\u0131rmas\u0131<\/strong><\/td>\n<td>\u00dc\u00e7 Faz + N\u00f6tr<\/td>\n<\/tr>\n<tr>\n<td><strong>\u00c7\u0131k\u0131\u015f Gerilimi<\/strong><\/td>\n<td>360\/380\/400\/415 VAC (faz-faz); 208\/220\/230\/240 VAC (faz-n\u00f6tr)<\/td>\n<\/tr>\n<tr>\n<td><strong>AC Gerilim D\u00fczenleme<\/strong><\/td>\n<td>\u00b11%<\/td>\n<\/tr>\n<tr>\n<td><strong>Giri\u015f G\u00fc\u00e7 Fakt\u00f6r\u00fc<\/strong><\/td>\n<td>100% y\u00fck\u00fcnde \u22650,99<\/td>\n<\/tr>\n<tr>\n<td><strong>Tepe Fakt\u00f6r\u00fc<\/strong><\/td>\n<td>3:1 (Maks.)<\/td>\n<\/tr>\n<tr>\n<td><strong>AC Modunda Verimlilik<\/strong><\/td>\n<td>95.5%<\/td>\n<\/tr>\n<tr>\n<td><strong>Pil Modunda Verimlilik<\/strong><\/td>\n<td>94.5%<\/td>\n<\/tr>\n<tr>\n<td><strong>Boyutlar<\/strong><\/td>\n<td>797 \u00d7 438 \u00d7 176 mm (4U)<\/td>\n<\/tr>\n<tr>\n<td><strong>Net A\u011f\u0131rl\u0131k<\/strong><\/td>\n<td>45 kg<\/td>\n<\/tr>\n<tr>\n<td><strong>Koruma Seviyesi<\/strong><\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0130leti\u015fim<\/strong><\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td><strong>\u0130ste\u011fe Ba\u011fl\u0131 Y\u00f6netim<\/strong><\/td>\n<td>SNMP \/ Web \u00dczerinden Y\u00f6netim<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u00dcr\u00fcn G\u00f6r\u00fcn\u00fcmleri ve Teknik Referans<\/h3>\n<figure class=\"wp-block-image size-full\"><figcaption>DAXIN HR33 60KL Y\u00fcksek Frekansl\u0131 Raf\/Kule Tipi D\u00f6n\u00fc\u015ft\u00fcr\u00fclebilir UPS \u00dcr\u00fcn Sayfas\u0131.<\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\"><\/figure>\n<h3>Tipik Uygulamalar<\/h3>\n<p>DAXIN HR33-60KL 60 kVA \u00fc\u00e7 fazl\u0131 \u00e7evrimi\u00e7i UPS, veri merkezleri, telekom tesisleri, sunucu odalar\u0131, a\u011f altyap\u0131s\u0131, end\u00fcstriyel kontrol sistemleri ve g\u00fcvenilir ve kesintisiz g\u00fc\u00e7 korumas\u0131 gerektiren di\u011fer g\u00f6rev a\u00e7\u0131s\u0131ndan kritik elektrik y\u00fckleri dahil olmak \u00fczere kritik g\u00fc\u00e7 uygulamalar\u0131 i\u00e7in tasarlanm\u0131\u015ft\u0131r.<\/p>\n<h3>Se\u00e7im ve Proje Planlamas\u0131<\/h3>\n<p>DAXIN HR33-60KL modelini se\u00e7meden \u00f6nce, toplam kritik y\u00fck\u00fc, giri\u015f\/\u00e7\u0131k\u0131\u015f gerilimini, \u00fc\u00e7 fazl\u0131 sistem gereksinimlerini, gerekli yedek \u00e7al\u0131\u015fma s\u00fcresini, ak\u00fc konfig\u00fcrasyonunu, baypas d\u00fczenini, ileti\u015fim aray\u00fcz\u00fcn\u00fc, yedeklilik gereksinimlerini ve kurulum ortam\u0131n\u0131 teyit ediniz. DAXIN ENERGY, UPS ve ak\u00fc sistemi se\u00e7imine destek olmak \u00fczere proje y\u00fck verilerini ve elektriksel gereksinimleri inceleyebilir.<\/p>\n<h3>S\u0131k Sorulan Sorular<\/h3>\n<p><strong>Bu \u00fcr\u00fcn belirli bir projeye g\u00f6re \u00f6zelle\u015ftirilebilir mi?<\/strong><\/p>\n<p>Evet. Elektrik konfig\u00fcrasyonu, pil \u00e7al\u0131\u015fma s\u00fcresi, ileti\u015fim, baypas, kabin d\u00fczeni ve proje aksesuarlar\u0131, tesisin gereksinimlerine g\u00f6re g\u00f6zden ge\u00e7irilebilir.<\/p>\n<p><strong>T\u00fcm teknik derecelendirmeler serinin tamam\u0131nda ortak m\u0131d\u0131r?<\/strong><\/p>\n<p>Hay\u0131r. Teknik \u00f6zellikler ve i\u015flevler modele ve yap\u0131land\u0131rmaya g\u00f6re de\u011fi\u015fiklik g\u00f6sterir. Nihai referans olarak projeye \u00f6zg\u00fc teknik veri sayfas\u0131n\u0131 kullan\u0131n.<\/p>\n<p><strong>DAXIN ENERGY, sistem se\u00e7iminde destek sa\u011flayabilir mi?<\/strong><\/p>\n<p>Evet. Y\u00fck listesini, faz ve gerilimi, gerekli \u00e7al\u0131\u015fma s\u00fcresini, yedeklilik hedefini, ileti\u015fim gereksinimlerini ve kurulum ortam\u0131n\u0131 belirtin.<\/p>\n<h3>Proje Yap\u0131land\u0131rmas\u0131 Talep Et<\/h3>\n<p>\u00d6zel olarak haz\u0131rlanm\u0131\u015f bir UPS veya ak\u00fc teklifi almak i\u00e7in y\u00fck verilerini, tek hat \u015femas\u0131n\u0131, gerekli yedekleme s\u00fcresini ve saha ko\u015fullar\u0131n\u0131 bize g\u00f6nderin.<\/p>\n<p><strong>DAXIN HR33-60KL modelinin g\u00fc\u00e7 kapasitesi nedir?<\/strong><\/p>\n<p data-start=\"6129\" data-end=\"6236\">DAXIN HR33-60KL, 60 kVA\/60 kW nominal g\u00fcce sahiptir ve \u00fc\u00e7 fazl\u0131 kritik g\u00fc\u00e7 uygulamalar\u0131 i\u00e7in tasarlanm\u0131\u015ft\u0131r.<\/p>\n<h3 data-section-id=\"z86mev\" data-start=\"6238\" data-end=\"6277\">HR33-60KL \u00fc\u00e7 fazl\u0131 bir UPS mi?<\/h3>\n<p data-start=\"6279\" data-end=\"6443\">Evet. HR33-60KL, \u00fc\u00e7 fazl\u0131 bir sistem mimarisi kullan\u0131r ve zorlu veri merkezi, telekom, sunucu odas\u0131 ve di\u011fer kritik g\u00fc\u00e7 uygulamalar\u0131 i\u00e7in tasarlanm\u0131\u015ft\u0131r.<\/p>\n<h3 data-section-id=\"ydk15w\" data-start=\"6445\" data-end=\"6503\">60 kVA\u2019l\u0131k bir \u00e7evrimi\u00e7i UPS hangi uygulamalar i\u00e7in uygundur?<\/h3>\n<p data-start=\"6505\" data-end=\"6837\">60 kVA\u2019l\u0131k bir \u00e7evrimi\u00e7i UPS, veri merkezleri, telekom tesisleri, sunucu odalar\u0131, a\u011f altyap\u0131s\u0131, end\u00fcstriyel kontrol sistemleri ve kesintisiz koruma alt\u0131nda g\u00fc\u00e7 gerektiren di\u011fer uygulamalarda uygun boyutland\u0131r\u0131lm\u0131\u015f kritik y\u00fckleri destekleyebilir. Nihai UPS boyutland\u0131rmas\u0131, ger\u00e7ek y\u00fck, yedeklilik hedefi ve gerekli yedek \u00e7al\u0131\u015fma s\u00fcresine g\u00f6re belirlenmelidir.<\/p>\n<h3 data-section-id=\"ooksra\" data-start=\"6839\" data-end=\"6889\">HR33-60KL, a\u011f izleme \u00f6zelli\u011fini destekliyor mu?<\/h3>\n<p data-start=\"6891\" data-end=\"7026\">Teknik \u00f6zellikler listesinde RS-232\/USB ileti\u015fim aray\u00fczleri ve a\u011f tabanl\u0131 g\u00fc\u00e7 y\u00f6netimi i\u00e7in iste\u011fe ba\u011fl\u0131 SNMP deste\u011fi yer almaktad\u0131r.<\/p>","protected":false},"excerpt":{"rendered":"<p>DAXIN HR33-60KL, veri merkezleri, telekom tesisleri, sunucu odalar\u0131 ve di\u011fer kritik sistemler i\u00e7in g\u00fcvenilir g\u00fc\u00e7 korumas\u0131 sa\u011flamak \u00fczere tasarlanm\u0131\u015f, 60 kVA\/60 kW g\u00fcc\u00fcnde \u00fc\u00e7 fazl\u0131, y\u00fcksek frekansl\u0131 bir \u00e7evrimi\u00e7i UPS\u2019tir. Pil, \u00e7al\u0131\u015fma s\u00fcresi, ileti\u015fim ve projeye \u00f6zg\u00fc elektriksel konfig\u00fcrasyonlar, uygulama gereksinimlerine g\u00f6re se\u00e7ilebilir.<\/p>","protected":false},"featured_media":4890,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[106,98,97],"product_tag":[],"class_list":["post-2903","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-high-frequency-rack-tower-convertible-ups","product_cat-high-frequency-ups","product_cat-ups-solutions","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product\/2903","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/comments?post=2903"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/media\/4890"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/media?parent=2903"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2903"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2903"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2903"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}