{"id":2270,"date":"2026-07-11T19:07:25","date_gmt":"2026-07-11T11:07:25","guid":{"rendered":"https:\/\/btrytech.com\/?post_type=product&#038;p=2270"},"modified":"2026-08-14T01:22:01","modified_gmt":"2026-08-13T17:22:01","slug":"daxin-energy-ex3c3-10kva-three-phase-online-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/tr\/product\/daxin-energy-ex3c3-10kva-three-phase-online-ups\/","title":{"rendered":"DAXIN ENERGY EX3C3 10 kVA \u00dc\u00e7 Fazl\u0131 \u00c7evrimi\u00e7i UPS"},"content":{"rendered":"<h2>EX3C3 10kVA Three-Phase Online UPS<\/h2>\n<p>The DAXIN ENERGY EX3C3 10kVA online UPS is designed for critical equipment that requires stable, clean and uninterrupted power. Its online double-conversion topology protects connected loads from voltage fluctuation, frequency variation, harmonic interference, electrical noise and unexpected power interruptions.<\/p>\n<h2>Temel \u00d6zellikler<\/h2>\n<h3>Reliable Online Double-Conversion Design<\/h3>\n<ul>\n<li>True online double-conversion topology provides clean sine wave output for sensitive equipment.<\/li>\n<li>Output frequency tracking, phase locking, voltage regulation and noise filtering help reduce the impact of unstable utility power.<\/li>\n<li>Advanced modular dual-CPU control improves UPS reliability, operating stability and overall system performance.<\/li>\n<li>Wide AC input voltage range reduces unnecessary battery discharge in areas with poor grid conditions.<\/li>\n<li>DC start function allows the UPS to start directly from battery when utility power is unavailable.<\/li>\n<\/ul>\n<h3>High Input Power Factor and Low Harmonic Interference<\/h3>\n<ul>\n<li>Advanced PFC technology keeps the input power factor close to 1 under different load and utility voltage conditions.<\/li>\n<li>Input harmonic filter design reduces feedback pollution to the utility grid.<\/li>\n<li>Input and output harmonic filters help minimize UPS interference with the power system.<\/li>\n<li>High-frequency filtering and synchronization technology improves generator compatibility.<\/li>\n<\/ul>\n<h3>Complete Protection Functions<\/h3>\n<ul>\n<li>Output overload protection.<\/li>\n<li>Output short-circuit protection.<\/li>\n<li>Inverter over-temperature protection.<\/li>\n<li>Battery low-voltage warning protection.<\/li>\n<li>Battery overcharge protection.<\/li>\n<li>Manual maintenance bypass switch supports easier service while keeping load power supplied through bypass.<\/li>\n<\/ul>\n<h3>LCD Display and Communication Management<\/h3>\n<ul>\n<li>LCD display shows UPS operating status, system parameters and alarm information in real time.<\/li>\n<li>RS232 \/ USB communication interfaces support local monitoring and computer communication.<\/li>\n<li>Optional SNMP network adapter enables remote UPS monitoring and centralized power management.<\/li>\n<li>Compatible UPS monitoring software provides clear visibility of system operating data.<\/li>\n<\/ul>\n<h3>Optional Intelligent Battery Monitoring<\/h3>\n<ul>\n<li>Supports single battery detection and monitoring.<\/li>\n<li>Provides over-voltage, under-voltage and voltage difference alarm functions.<\/li>\n<li>Battery fault information can be displayed on the screen to help administrators respond quickly.<\/li>\n<\/ul>\n<h3>Strong Environmental Adaptability<\/h3>\n<p>The circuit boards are installed in a fully enclosed structure and treated with conformal coating, improving reliability in harsh environments such as tunnels, plazas, industrial sites and demanding equipment rooms.<\/p>\n<h2>Tipik Uygulamalar<\/h2>\n<ul>\n<li>Small data centers and server rooms<\/li>\n<li>Telecom equipment rooms<\/li>\n<li>Industrial automation systems<\/li>\n<li>T\u0131bbi ve laboratuvar ekipmanlar\u0131<\/li>\n<li>G\u00fcvenlik ve izleme sistemleri<\/li>\n<li>Commercial buildings and office power backup<\/li>\n<li>Emergency backup power systems<\/li>\n<\/ul>\n<h2>Technical Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Model<\/th>\n<td>EX3C3-10kVA<\/td>\n<\/tr>\n<tr>\n<th>Kapasite<\/th>\n<td>10kVA \/ 9kW<\/td>\n<\/tr>\n<tr>\n<th>Topoloji<\/th>\n<td>Online double-conversion UPS<\/td>\n<\/tr>\n<tr>\n<th>Input Phase<\/th>\n<td>Three-phase grounded<\/td>\n<\/tr>\n<tr>\n<th>Input Voltage Range<\/th>\n<td>110VAC (Ph-N) +\/-3% at 50% load; 176VAC (Ph-N) +\/-3% at 100% load<\/td>\n<\/tr>\n<tr>\n<th>Giri\u015f Frekans\u0131<\/th>\n<td>45-55Hz at 50Hz; 56-65Hz at 60Hz<\/td>\n<\/tr>\n<tr>\n<th>Giri\u015f G\u00fc\u00e7 Fakt\u00f6r\u00fc<\/th>\n<td>&gt; 0.99 at 100% load<\/td>\n<\/tr>\n<tr>\n<th>\u00c7\u0131k\u0131\u015f Gerilimi<\/th>\n<td>3 x 360 \/ 380 \/ 400 \/ 415VAC, three-phase<\/td>\n<\/tr>\n<tr>\n<th>AC Gerilim D\u00fczenleme<\/th>\n<td>+\/-0.3%<\/td>\n<\/tr>\n<tr>\n<th>\u00c7\u0131k\u0131\u015f Frekans\u0131<\/th>\n<td>46-54Hz or 56-64Hz in synchronized mode; 50Hz +\/-0.1Hz or 60Hz +\/-0.1Hz in battery mode<\/td>\n<\/tr>\n<tr>\n<th>Tepe Fakt\u00f6r\u00fc<\/th>\n<td>3:1<\/td>\n<\/tr>\n<tr>\n<th>\u00c7\u0131k\u0131\u015f THD'si<\/th>\n<td>&lt;=1% with linear load; &lt;=2% with nonlinear load<\/td>\n<\/tr>\n<tr>\n<th>Transfer S\u00fcresi<\/th>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<th>Verimlilik<\/th>\n<td>&gt; 90.5% in AC mode; &gt; 87% in battery mode<\/td>\n<\/tr>\n<tr>\n<th>Pil Adedi<\/th>\n<td>16-20 pcs adjustable, preset 16 pcs<\/td>\n<\/tr>\n<tr>\n<th>\u015earj Ak\u0131m\u0131<\/th>\n<td>4.0A +\/-10%<\/td>\n<\/tr>\n<tr>\n<th>Boyutlar<\/th>\n<td>592 x 250 x 576 mm<\/td>\n<\/tr>\n<tr>\n<th>Net A\u011f\u0131rl\u0131k<\/th>\n<td>38 kg<\/td>\n<\/tr>\n<tr>\n<th>\u00c7al\u0131\u015fma S\u0131cakl\u0131\u011f\u0131<\/th>\n<td>0-40 deg C<\/td>\n<\/tr>\n<tr>\n<th>Ba\u011f\u0131l Nem<\/th>\n<td>&lt; 95%, non-condensing<\/td>\n<\/tr>\n<tr>\n<th>G\u00fcr\u00fclt\u00fc<\/th>\n<td>&lt; 60dB at 1m<\/td>\n<\/tr>\n<tr>\n<th>\u0130leti\u015fim<\/th>\n<td>RS232 \/ USB, optional SNMP<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure id=\"attachment_2275\" class=\"wp-caption aligncenter\" style=\"width: 2400px;\" aria-describedby=\"caption-attachment-2275\">\n<p><figure id=\"attachment_4867\" aria-describedby=\"caption-attachment-4867\" style=\"width: 970px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4867\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-20kva-three-phase-online-ups-technical-specifications-english.png.webp\" alt=\"DAXIN EX3C3 20kVA 3\/3 Phase Online UPS Technical Specifications\" width=\"970\" height=\"889\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-20kva-three-phase-online-ups-technical-specifications-english.png.webp 970w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-20kva-three-phase-online-ups-technical-specifications-english.png-300x275.webp 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-20kva-three-phase-online-ups-technical-specifications-english.png-768x704.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/07\/daxin-ex3c3-20kva-three-phase-online-ups-technical-specifications-english.png-13x12.webp 13w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" \/><figcaption id=\"caption-attachment-4867\" class=\"wp-caption-text\">Technical specifications for the DAXIN EX3C3 20kVA 3\/3 phase online UPS and EX3C3 series reference models.<\/figcaption><\/figure><figcaption id=\"caption-attachment-2275\" class=\"wp-caption-text\">Technical specifications for DAXIN ENERGY EX3C3 series three-phase online UPS, including the 10kVA model.<\/figcaption><\/figure>\n<figure id=\"attachment_2232\" class=\"wp-caption aligncenter\" style=\"width: 982px;\" aria-describedby=\"caption-attachment-2232\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2232\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2270-detail-02.webp\" alt=\"DAXIN ENERGY EX3C3 10kVA Three-Phase Online UPS technical detail 2 by DAXIN ENERGY\" width=\"982\" height=\"664\" \/><figcaption id=\"caption-attachment-2232\" class=\"wp-caption-text\">Key features of DAXIN ENERGY online UPS, including stable power, wide voltage range, energy saving and easy operation.<\/figcaption><\/figure>","protected":false},"excerpt":{"rendered":"<p>DAXIN ENERGY EX3C3 10kVA three-phase online UPS provides reliable double-conversion power protection for small data centers, telecom rooms, industrial control systems, medical equipment, security systems and commercial backup power applications. With pure sine wave output, high input power factor, wide AC input voltage range, LCD display, RS232 \/ USB communication and optional SNMP monitoring, it delivers stable and clean power for sensitive equipment.<\/p>","protected":false},"featured_media":4868,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[98,104],"product_tag":[],"class_list":["post-2270","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-high-frequency-ups","product_cat-hf-3-3-phase-ups","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product\/2270","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/comments?post=2270"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/media\/4868"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/media?parent=2270"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product_brand?post=2270"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product_cat?post=2270"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/tr\/wp-json\/wp\/v2\/product_tag?post=2270"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}