Açıklama
What Is the DAXIN RM33 200kVA Modular Online UPS?
The DAXIN RM33 200kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.
Its modular cabinet architecture integrates power modules, system control, protection and service access within a scalable UPS platform. The reference configuration provides 200kW cabinet capacity and supports external battery packs for project-specific backup requirements.
The RM33 series supports 3 × 380/400/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.
Final installed capacity, power-module configuration, battery runtime, redundancy architecture, communications and project accessories should be confirmed against the approved DAXIN technical proposal.
| Parametre | RM33-200kVA |
|---|---|
| Model | RM33-200kVA |
| UPS Türü | Modüler Çevrimiçi UPS |
| Aşama | Üç Fazlı Giriş / Üç Fazlı Çıkış |
| Dolap Kapasitesi | 200kW |
| Pil Türü | Harici Pil Paketi |
| Pil Dolabı Kapasitesi | 20kVA / 20kW |
| İsteğe Bağlı Pil Dolapları | 10 |
| Giriş Gerilimi | 3 × 380/400/415 VAC (3 faz + N) |
| Giriş Frekansı | 50/60 Hz Otomatik Algılama |
| Giriş Frekans Aralığı | 40–70 Hz |
| Giriş Güç Faktörü | ≥0,99 @ 100% Yük |
| Giriş Akımı THDi | <2% @ 100% Yük |
| Çıkış Gerilimi | 3 × 380/400/415 VAC (3 faz + N) |
| Statik Gerilim Kararlılığı | ≤±0,31 TP3T Tipik Yük |
| Dinamik Gerilim Kararlılığı | ≤±3% Tipik Yük |
| Çıkış Frekansı | 50/60 Hz |
| Çıkış THD'si | ≤1% Doğrusal / ≤2% Doğrusal Olmayan |
| Verimlilik | En fazla 96,51 TP3T |
| Boyutlar | 1100 × 600 × 2010mm |
| Net Ağırlık | 282kg |
| Çalışma Sıcaklığı | 0–40 °C |
| Rakım | <1000m Rated Power |
| Koruma Sınıfı | IP20 |
| İletişim | RS-232 / USB |
| Ağ Yönetimi | İsteğe bağlı SNMP |

Başlıca Avantajlar
- Ölçeklenebilir Modüler Mimari: Modular UPS design supports flexible capacity planning and future system expansion.
- 200kW Cabinet Capacity: The RM33-200kVA reference cabinet is designed for large three-phase critical-power applications.
- Üç Fazlı Güç Koruması: Supports 3 × 380/400/415VAC three-phase input and output for data center, telecom and industrial electrical systems.
- Düşük Giriş Harmonik Bozulması: Tam yükte 2%’nin altındaki giriş akımı THDi değeri, yukarı akıştaki elektriksel etkiyi azaltmaya yardımcı olur.
- Yüksek Giriş Güç Katsayısı: 100% yükünde giriş güç faktörü en az 0,99’dur.
- Yüksek Verimlilik: Sistem verimliliği 96,51 TP3T’ye kadar belirtilmiştir.
- External Battery Configuration: Battery systems can be engineered according to required backup runtime and project requirements.
- Uzaktan İzleme: RS-232/USB iletişimi desteklenmektedir; isteğe bağlı SNMP ağ yönetimi de mevcuttur.
Modüler UPS Sistemi Nedir?
A modular UPS system uses multiple power modules within a common cabinet architecture instead of relying on a single fixed-capacity power stage.
This approach allows UPS capacity, maintenance strategy and redundancy architecture to be planned according to the critical load and future expansion requirements.
The DAXIN RM33 series combines modular power architecture with centralized control, external battery systems and network-management options for scalable critical-power applications.
Why Choose a 200kVA Modular UPS for a Data Center?
A modular UPS can help data center operators align installed power capacity with the actual critical load while preserving a path for future expansion and redundancy planning.
The DAXIN RM33-200kVA combines three-phase online power protection, modular system architecture, external battery configuration and optional network monitoring for data center and mission-critical infrastructure applications.
Final system sizing should consider the IT load in kW and kVA, power factor, redundancy target, expected expansion, required battery autonomy and upstream electrical architecture.
Tipik Uygulamalar
- Veri merkezleri ve sunucu odaları
- Telekom çekirdek tesisleri ve ağ altyapısı
- Endüstriyel otomasyon ve üretim tesisleri
- Finans ve bankacılık hizmetleri
- Sağlık hizmetleri ve tıbbi altyapı
- Ulaşım ve kamu altyapısı
- Kurumsal BT tesisleri
- Diğer ölçeklenebilir, görev açısından kritik güç sistemleri
Seçim ve Proje Planlaması
Sipariş vermeden önce, seçilen modele ve proje çizimlerine göre tam güç değerini, giriş/çıkış fazını, gerilimi, frekansı, güç faktörünü, akü gerilimini, çalışma süresini, baypas özelliğini, iletişim özelliklerini, boyutları, çevresel sınırları ve kurulum yöntemini teyit ediniz.
Sık Sorulan Sorular
Bu ürün belirli bir projeye göre özelleştirilebilir mi?
Evet. Elektrik konfigürasyonu, pil çalışma süresi, iletişim, baypas, kabin düzeni ve proje aksesuarları, tesisin gereksinimlerine göre gözden geçirilebilir.
Tüm teknik derecelendirmeler serinin tamamında ortak mıdır?
Hayır. Teknik özellikler ve işlevler modele ve yapılandırmaya göre değişiklik gösterir. Nihai referans olarak projeye özgü teknik veri sayfasını kullanın.
DAXIN ENERGY, sistem seçiminde destek sağlayabilir mi?
Evet. Yük listesini, faz ve gerilimi, gerekli çalışma süresini, yedeklilik hedefini, iletişim gereksinimlerini ve kurulum ortamını belirtin.
Proje Yapılandırması Talep Et
Özel olarak hazırlanmış bir UPS veya akü teklifi almak için yük verilerini, tek hat şemasını, gerekli yedekleme süresini ve saha koşullarını bize gönderin.
What is the DAXIN RM33-200kVA?
The DAXIN RM33-200kVA is a three-phase modular online UPS system designed for scalable critical-power applications.
What is the cabinet capacity?
The supplied RM33 series specification lists 200kW cabinet capacity for the RM33-200kVA configuration.
Hangi giriş ve çıkış gerilimlerini destekliyor?
Referans teknik özellik belgesinde 3 × 380/400/415 VAC üç fazlı giriş ve çıkış değerleri belirtilmiştir.
Giriş güç faktörü ve THDi değerleri nedir?
Referans teknik özelliklerinde, tam yükte en az 0,99 giriş güç faktörü ve 2%’nin altında bir giriş akımı THDi değeri belirtilmiştir.
RM33, uzaktan izleme özelliğini destekliyor mu?
Yes. RS-232/USB communication is supported, and SNMP network management is available as an option.
How should the RM33-200kVA system be configured?
Final configuration should consider the critical load, required redundancy, future expansion, battery runtime, electrical distribution, communication requirements and installation environment.







Yorumlar
Henüz herhangi bir yorum yok.