{"id":2314,"date":"2026-07-17T20:12:07","date_gmt":"2026-07-17T12:12:07","guid":{"rendered":"https:\/\/btrytech.com\/?post_type=product&#038;p=2314"},"modified":"2026-08-13T22:07:06","modified_gmt":"2026-08-13T14:07:06","slug":"ex3c3-100kva-online-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/th\/product\/ex3c3-100kva-online-ups\/","title":{"rendered":"EX3C3 100kVA UPS \u0e41\u0e1a\u0e1a\u0e2d\u0e2d\u0e19\u0e44\u0e25\u0e19\u0e4c | UPS \u0e2a\u0e32\u0e21\u0e40\u0e1f\u0e2a \u2013 DAXIN ENERGY"},"content":{"rendered":"<p><!-- DAXIN-HF-SEO-GEO-04-START --><\/p>\n<section class=\"daxin-customer-selection-guide\">\n<h2>UPS \u0e19\u0e35\u0e49\u0e40\u0e2b\u0e21\u0e32\u0e30\u0e2a\u0e21\u0e01\u0e31\u0e1a\u0e42\u0e04\u0e23\u0e07\u0e01\u0e32\u0e23\u0e02\u0e2d\u0e07\u0e04\u0e38\u0e13\u0e2b\u0e23\u0e37\u0e2d\u0e44\u0e21\u0e48?<\/h2>\n<p>The DAXIN EX3C3 100kVA is a true online double-conversion UPS for critical three-phase loads that require stable voltage, low output distortion and seamless battery transition.<\/p>\n<p>It provides a practical capacity point for facilities that have outgrown smaller UPS systems but do not require a 120kVA or larger platform.<\/p>\n<h2>\u0e01\u0e32\u0e23\u0e43\u0e0a\u0e49\u0e07\u0e32\u0e19\u0e17\u0e31\u0e48\u0e27\u0e44\u0e1b<\/h2>\n<ul>\n<li>Data centers and server facilities<\/li>\n<li>Industrial automation<\/li>\n<li>Healthcare and laboratories<\/li>\n<li>Telecommunications and financial services<\/li>\n<\/ul>\n<h2>\u0e2a\u0e34\u0e48\u0e07\u0e17\u0e35\u0e48\u0e04\u0e27\u0e23\u0e15\u0e23\u0e27\u0e08\u0e2a\u0e2d\u0e1a\u0e01\u0e48\u0e2d\u0e19\u0e2a\u0e31\u0e48\u0e07\u0e0b\u0e37\u0e49\u0e2d<\/h2>\n<ul>\n<li>Load level and overload behavior<\/li>\n<li>Input\/output voltage and frequency<\/li>\n<li>Battery autonomy and charging current<\/li>\n<li>Monitoring, bypass and service requirements<\/li>\n<\/ul>\n<h2>\u0e04\u0e33\u0e16\u0e32\u0e21\u0e17\u0e35\u0e48\u0e21\u0e31\u0e01\u0e16\u0e39\u0e01\u0e16\u0e32\u0e21<\/h2>\n<h3>\u0e04\u0e27\u0e23\u0e40\u0e25\u0e37\u0e2d\u0e01\u0e04\u0e27\u0e32\u0e21\u0e08\u0e38\u0e02\u0e2d\u0e07 UPS \u0e2d\u0e22\u0e48\u0e32\u0e07\u0e44\u0e23?<\/h3>\n<p>\u0e40\u0e23\u0e34\u0e48\u0e21\u0e15\u0e49\u0e19\u0e08\u0e32\u0e01\u0e1b\u0e23\u0e34\u0e21\u0e32\u0e13\u0e42\u0e2b\u0e25\u0e14\u0e15\u0e48\u0e2d\u0e40\u0e19\u0e37\u0e48\u0e2d\u0e07\u0e17\u0e35\u0e48\u0e27\u0e31\u0e14\u0e44\u0e14\u0e49 \u0e1b\u0e23\u0e34\u0e21\u0e32\u0e13\u0e42\u0e2b\u0e25\u0e14\u0e43\u0e19\u0e0a\u0e48\u0e27\u0e07\u0e40\u0e23\u0e34\u0e48\u0e21\u0e15\u0e49\u0e19\u0e23\u0e30\u0e1a\u0e1a \u0e2b\u0e23\u0e37\u0e2d\u0e04\u0e27\u0e32\u0e21\u0e15\u0e49\u0e2d\u0e07\u0e01\u0e32\u0e23\u0e2a\u0e39\u0e07\u0e2a\u0e38\u0e14 \u0e41\u0e25\u0e30\u0e41\u0e1c\u0e19\u0e01\u0e32\u0e23\u0e02\u0e22\u0e32\u0e22\u0e15\u0e31\u0e27\u0e17\u0e35\u0e48\u0e04\u0e32\u0e14\u0e01\u0e32\u0e23\u0e13\u0e4c\u0e44\u0e27\u0e49 DAXIN ENERGY \u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e15\u0e23\u0e27\u0e08\u0e2a\u0e2d\u0e1a\u0e23\u0e32\u0e22\u0e0a\u0e37\u0e48\u0e2d\u0e42\u0e2b\u0e25\u0e14\u0e41\u0e25\u0e30\u0e40\u0e2a\u0e19\u0e2d\u0e41\u0e19\u0e30\u0e02\u0e2d\u0e1a\u0e40\u0e02\u0e15\u0e01\u0e32\u0e23\u0e14\u0e33\u0e40\u0e19\u0e34\u0e19\u0e07\u0e32\u0e19\u0e17\u0e35\u0e48\u0e40\u0e2b\u0e21\u0e32\u0e30\u0e2a\u0e21.<\/p>\n<h3>\u0e23\u0e30\u0e22\u0e30\u0e40\u0e27\u0e25\u0e32\u0e01\u0e32\u0e23\u0e43\u0e0a\u0e49\u0e07\u0e32\u0e19\u0e02\u0e2d\u0e07\u0e41\u0e1a\u0e15\u0e40\u0e15\u0e2d\u0e23\u0e35\u0e48\u0e16\u0e39\u0e01\u0e01\u0e33\u0e2b\u0e19\u0e14\u0e2d\u0e22\u0e48\u0e32\u0e07\u0e44\u0e23?<\/h3>\n<p>\u0e40\u0e27\u0e25\u0e32\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19\u0e02\u0e36\u0e49\u0e19\u0e2d\u0e22\u0e39\u0e48\u0e01\u0e31\u0e1a\u0e1b\u0e23\u0e34\u0e21\u0e32\u0e13\u0e42\u0e2b\u0e25\u0e14 \u0e04\u0e27\u0e32\u0e21\u0e15\u0e36\u0e07\u0e02\u0e2d\u0e07\u0e41\u0e1a\u0e15\u0e40\u0e15\u0e2d\u0e23\u0e35\u0e48 \u0e04\u0e27\u0e32\u0e21\u0e08\u0e38\u0e02\u0e2d\u0e07\u0e41\u0e1a\u0e15\u0e40\u0e15\u0e2d\u0e23\u0e35\u0e48 \u0e2d\u0e32\u0e22\u0e38\u0e02\u0e2d\u0e07\u0e41\u0e1a\u0e15\u0e40\u0e15\u0e2d\u0e23\u0e35\u0e48 \u0e2d\u0e38\u0e13\u0e2b\u0e20\u0e39\u0e21\u0e34 \u0e41\u0e25\u0e30\u0e1b\u0e23\u0e30\u0e2a\u0e34\u0e17\u0e18\u0e34\u0e20\u0e32\u0e1e\u0e02\u0e2d\u0e07\u0e2d\u0e34\u0e19\u0e40\u0e27\u0e2d\u0e23\u0e4c\u0e40\u0e15\u0e2d\u0e23\u0e4c \u0e42\u0e1b\u0e23\u0e14\u0e41\u0e08\u0e49\u0e07\u0e23\u0e30\u0e22\u0e30\u0e40\u0e27\u0e25\u0e32\u0e2a\u0e33\u0e23\u0e2d\u0e07\u0e17\u0e35\u0e48\u0e08\u0e33\u0e40\u0e1b\u0e47\u0e19\u0e41\u0e25\u0e30\u0e1b\u0e23\u0e34\u0e21\u0e32\u0e13\u0e42\u0e2b\u0e25\u0e14\u0e1b\u0e01\u0e15\u0e34 \u0e40\u0e1e\u0e37\u0e48\u0e2d\u0e43\u0e0a\u0e49\u0e43\u0e19\u0e01\u0e32\u0e23\u0e04\u0e33\u0e19\u0e27\u0e13\u0e42\u0e04\u0e23\u0e07\u0e01\u0e32\u0e23.<\/p>\n<h3>UPS \u0e19\u0e35\u0e49\u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e17\u0e33\u0e07\u0e32\u0e19\u0e23\u0e48\u0e27\u0e21\u0e01\u0e31\u0e1a\u0e40\u0e04\u0e23\u0e37\u0e48\u0e2d\u0e07\u0e01\u0e33\u0e40\u0e19\u0e34\u0e14\u0e44\u0e1f\u0e1f\u0e49\u0e32\u0e2b\u0e23\u0e37\u0e2d\u0e23\u0e30\u0e1a\u0e1a\u0e15\u0e34\u0e14\u0e15\u0e32\u0e21\u0e23\u0e30\u0e22\u0e30\u0e44\u0e01\u0e25\u0e44\u0e14\u0e49\u0e2b\u0e23\u0e37\u0e2d\u0e44\u0e21\u0e48?<\/h3>\n<p>\u0e04\u0e27\u0e32\u0e21\u0e40\u0e02\u0e49\u0e32\u0e01\u0e31\u0e19\u0e44\u0e14\u0e49\u0e23\u0e30\u0e2b\u0e27\u0e48\u0e32\u0e07\u0e40\u0e04\u0e23\u0e37\u0e48\u0e2d\u0e07\u0e01\u0e33\u0e40\u0e19\u0e34\u0e14\u0e44\u0e1f\u0e1f\u0e49\u0e32\u0e41\u0e25\u0e30\u0e23\u0e30\u0e1a\u0e1a\u0e15\u0e34\u0e14\u0e15\u0e32\u0e21\u0e02\u0e36\u0e49\u0e19\u0e2d\u0e22\u0e39\u0e48\u0e01\u0e31\u0e1a\u0e23\u0e38\u0e48\u0e19\u0e41\u0e25\u0e30\u0e23\u0e39\u0e1b\u0e41\u0e1a\u0e1a\u0e01\u0e32\u0e23\u0e15\u0e31\u0e49\u0e07\u0e04\u0e48\u0e32\u0e17\u0e35\u0e48\u0e40\u0e25\u0e37\u0e2d\u0e01 \u0e42\u0e1b\u0e23\u0e14\u0e15\u0e23\u0e27\u0e08\u0e2a\u0e2d\u0e1a\u0e04\u0e27\u0e32\u0e21\u0e08\u0e38\u0e02\u0e2d\u0e07\u0e40\u0e04\u0e23\u0e37\u0e48\u0e2d\u0e07\u0e01\u0e33\u0e40\u0e19\u0e34\u0e14\u0e44\u0e1f\u0e1f\u0e49\u0e32 \u0e04\u0e27\u0e32\u0e21\u0e40\u0e2a\u0e16\u0e35\u0e22\u0e23\u0e02\u0e2d\u0e07\u0e04\u0e27\u0e32\u0e21\u0e16\u0e35\u0e48 \u0e41\u0e25\u0e30\u0e2d\u0e34\u0e19\u0e40\u0e17\u0e2d\u0e23\u0e4c\u0e40\u0e1f\u0e0b\u0e17\u0e35\u0e48\u0e08\u0e33\u0e40\u0e1b\u0e47\u0e19 \u0e40\u0e0a\u0e48\u0e19 RS-232, RS-485, USB, Modbus \u0e2b\u0e23\u0e37\u0e2d SNMP \u0e01\u0e48\u0e2d\u0e19\u0e2a\u0e31\u0e48\u0e07\u0e0b\u0e37\u0e49\u0e2d.<\/p>\n<h2>\u0e02\u0e2d\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e01\u0e32\u0e23\u0e15\u0e31\u0e49\u0e07\u0e04\u0e48\u0e32\u0e42\u0e04\u0e23\u0e07\u0e01\u0e32\u0e23<\/h2>\n<p>\u0e2a\u0e48\u0e07\u0e23\u0e32\u0e22\u0e0a\u0e37\u0e48\u0e2d\u0e42\u0e2b\u0e25\u0e14 \u0e41\u0e23\u0e07\u0e14\u0e31\u0e19\u0e44\u0e1f\u0e1f\u0e49\u0e32\u0e17\u0e35\u0e48\u0e44\u0e0b\u0e15\u0e4c \u0e40\u0e27\u0e25\u0e32\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19\u0e17\u0e35\u0e48\u0e15\u0e49\u0e2d\u0e07\u0e01\u0e32\u0e23 \u0e2a\u0e20\u0e32\u0e1e\u0e41\u0e27\u0e14\u0e25\u0e49\u0e2d\u0e21\u0e01\u0e32\u0e23\u0e15\u0e34\u0e14\u0e15\u0e31\u0e49\u0e07 \u0e23\u0e27\u0e21\u0e16\u0e36\u0e07\u0e02\u0e49\u0e2d\u0e01\u0e33\u0e2b\u0e19\u0e14\u0e14\u0e49\u0e32\u0e19\u0e01\u0e32\u0e23\u0e2a\u0e37\u0e48\u0e2d\u0e2a\u0e32\u0e23\u0e41\u0e25\u0e30\u0e04\u0e27\u0e32\u0e21\u0e2a\u0e33\u0e23\u0e2d\u0e07\u0e43\u0e2b\u0e49\u0e01\u0e31\u0e1a DAXIN ENERGY \u0e01\u0e32\u0e23\u0e01\u0e33\u0e2b\u0e19\u0e14\u0e04\u0e48\u0e32\u0e2a\u0e38\u0e14\u0e17\u0e49\u0e32\u0e22\u0e08\u0e30\u0e02\u0e36\u0e49\u0e19\u0e2d\u0e22\u0e39\u0e48\u0e01\u0e31\u0e1a\u0e02\u0e49\u0e2d\u0e40\u0e2a\u0e19\u0e2d\u0e17\u0e32\u0e07\u0e40\u0e17\u0e04\u0e19\u0e34\u0e04\u0e17\u0e35\u0e48\u0e44\u0e14\u0e49\u0e23\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e2d\u0e19\u0e38\u0e21\u0e31\u0e15\u0e34.<\/p>\n<\/section>\n<p><!-- DAXIN-HF-SEO-GEO-04-END --><\/p>\n<p><!-- DAXIN-HF-VIDEO-04-START --><\/p>\n<section class=\"daxin-product-video\">\n<h2>\u0e27\u0e34\u0e14\u0e35\u0e42\u0e2d\u0e1c\u0e25\u0e34\u0e15\u0e20\u0e31\u0e13\u0e11\u0e4c UPS \u0e04\u0e27\u0e32\u0e21\u0e16\u0e35\u0e48\u0e2a\u0e39\u0e07 DAXIN \u0e40\u0e1e\u0e34\u0e48\u0e21\u0e40\u0e15\u0e34\u0e21<\/h2>\n<p>\u0e14\u0e39\u0e27\u0e34\u0e14\u0e35\u0e42\u0e2d\u0e2a\u0e32\u0e18\u0e34\u0e15\u0e1c\u0e25\u0e34\u0e15\u0e20\u0e31\u0e13\u0e11\u0e4c\u0e40\u0e1e\u0e37\u0e48\u0e2d\u0e15\u0e23\u0e27\u0e08\u0e2a\u0e2d\u0e1a\u0e23\u0e39\u0e1b\u0e41\u0e1a\u0e1a\u0e02\u0e2d\u0e07 UPS, \u0e2b\u0e19\u0e49\u0e32\u0e15\u0e48\u0e32\u0e07\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19 \u0e41\u0e25\u0e30\u0e15\u0e33\u0e41\u0e2b\u0e19\u0e48\u0e07\u0e01\u0e32\u0e23\u0e15\u0e34\u0e14\u0e15\u0e31\u0e49\u0e07\u0e02\u0e2d\u0e07\u0e23\u0e30\u0e1a\u0e1a \u0e01\u0e32\u0e23\u0e01\u0e33\u0e2b\u0e19\u0e14\u0e04\u0e48\u0e32\u0e17\u0e32\u0e07\u0e44\u0e1f\u0e1f\u0e49\u0e32\u0e02\u0e31\u0e49\u0e19\u0e2a\u0e38\u0e14\u0e17\u0e49\u0e32\u0e22\u0e08\u0e30\u0e02\u0e36\u0e49\u0e19\u0e2d\u0e22\u0e39\u0e48\u0e01\u0e31\u0e1a\u0e02\u0e49\u0e2d\u0e40\u0e2a\u0e19\u0e2d\u0e17\u0e32\u0e07\u0e40\u0e17\u0e04\u0e19\u0e34\u0e04\u0e17\u0e35\u0e48\u0e44\u0e14\u0e49\u0e23\u0e31\u0e1a\u0e01\u0e32\u0e23\u0e2d\u0e19\u0e38\u0e21\u0e31\u0e15\u0e34.<\/p>\n<div class=\"daxin-product-video-item\">\n<h3>Professional-Grade 100KVA UPS System with True Online Double Conversion Technology<\/h3>\n<figure class=\"wp-block-video\"><video src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-high-frequency-ups-befadb703763.mp4\" poster=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2314-gallery-01.webp?wsr\" preload=\"metadata\" controls=\"controls\" width=\"306\" height=\"306\">\u0e40\u0e1a\u0e23\u0e32\u0e27\u0e4c\u0e40\u0e0b\u0e2d\u0e23\u0e4c\u0e02\u0e2d\u0e07\u0e04\u0e38\u0e13\u0e44\u0e21\u0e48\u0e23\u0e2d\u0e07\u0e23\u0e31\u0e1a\u0e41\u0e17\u0e47\u0e01\u0e27\u0e34\u0e14\u0e35\u0e42\u0e2d.<\/video><figcaption>Professional-Grade 100KVA UPS System with True Online Double Conversion Technology &#8211; DAXIN ENERGY.<\/figcaption><\/figure>\n<\/div>\n<\/section>\n<p><!-- DAXIN-HF-VIDEO-04-END --><\/p>\n<h2>DAXIN ENERGY EX3C3 100kVA Three-Phase Online UPS<\/h2>\n<p>DAXIN ENERGY EX3C3 100kVA three-phase online UPS is designed for data centers,<br \/>\ntelecom facilities, industrial production lines, commercial buildings and critical<br \/>\ninfrastructure that require stable, continuous and clean power protection. With true<br \/>\nonline double-conversion topology, high input power factor, wide AC input voltage<br \/>\nrange and intelligent monitoring options, it delivers reliable 100kW backup power<br \/>\nfor mission-critical equipment.<\/p>\n<h3>\u0e04\u0e38\u0e13\u0e2a\u0e21\u0e1a\u0e31\u0e15\u0e34\u0e2b\u0e25\u0e31\u0e01<\/h3>\n<ul>\n<li>True online double-conversion UPS topology for stable output voltage and frequency.<\/li>\n<li>100kVA \/ 100kW power capacity for high-demand critical power applications.<\/li>\n<li>Pure sine wave output protects servers, telecom equipment, industrial systems and precision devices.<\/li>\n<li>Wide AC input voltage range reduces unnecessary battery discharge in unstable grid environments.<\/li>\n<li>Advanced PFC technology provides high input power factor and reduces harmonic pollution.<\/li>\n<li>Generator-compatible design; recommended generator capacity is 2 times the UPS capacity.<\/li>\n<li>Zero transfer time ensures continuous power protection during grid failure or voltage fluctuation.<\/li>\n<li>RS232, RS485 and optional SNMP enable remote UPS monitoring and intelligent power management.<\/li>\n<\/ul>\n<h3>Applications<\/h3>\n<ul>\n<li>\u0e28\u0e39\u0e19\u0e22\u0e4c\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e41\u0e25\u0e30\u0e2b\u0e49\u0e2d\u0e07\u0e40\u0e0b\u0e34\u0e23\u0e4c\u0e1f\u0e40\u0e27\u0e2d\u0e23\u0e4c<\/li>\n<li>Telecom base stations and communication rooms<\/li>\n<li>Industrial automation and manufacturing equipment<\/li>\n<li>Commercial buildings and facility backup power<\/li>\n<li>Control rooms, security systems and critical infrastructure<\/li>\n<\/ul>\n<h3>\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25\u0e17\u0e32\u0e07\u0e40\u0e17\u0e04\u0e19\u0e34\u0e04<\/h3>\n<table>\n<tbody>\n<tr>\n<th>\u0e41\u0e1a\u0e1a<\/th>\n<td>EX3C3-100kVA<\/td>\n<\/tr>\n<tr>\n<th>\u0e04\u0e27\u0e32\u0e21\u0e08\u0e38<\/th>\n<td>100kVA \/ 100kW<\/td>\n<\/tr>\n<tr>\n<th>UPS Topology<\/th>\n<td>True online double-conversion UPS<\/td>\n<\/tr>\n<tr>\n<th>\u0e02\u0e31\u0e49\u0e19\u0e15\u0e2d\u0e19\u0e01\u0e32\u0e23\u0e1b\u0e49\u0e2d\u0e19\u0e02\u0e49\u0e2d\u0e21\u0e39\u0e25<\/th>\n<td>\u0e2a\u0e32\u0e21\u0e40\u0e1f\u0e2a + \u0e2a\u0e32\u0e22\u0e01\u0e25\u0e32\u0e07<\/td>\n<\/tr>\n<tr>\n<th>\u0e0a\u0e48\u0e27\u0e07\u0e41\u0e23\u0e07\u0e14\u0e31\u0e19\u0e44\u0e1f\u0e1f\u0e49\u0e32\u0e40\u0e02\u0e49\u0e32<\/th>\n<td>110VAC (Ph-N) \u00b13% \u0e17\u0e35\u0e48\u0e42\u0e2b\u0e25\u0e14 50%; 176VAC (Ph-N) \u00b13% \u0e17\u0e35\u0e48\u0e42\u0e2b\u0e25\u0e14 100%<\/td>\n<\/tr>\n<tr>\n<th>High Input Voltage Transfer<\/th>\n<td>300VAC (L-N) \u00b13% at 50% load; 276VAC (L-N) \u00b13% at 100% load<\/td>\n<\/tr>\n<tr>\n<th>Input Frequency Range<\/th>\n<td>50 \/ 60Hz \u0e2a\u0e32\u0e21\u0e32\u0e23\u0e16\u0e40\u0e25\u0e37\u0e2d\u0e01\u0e2d\u0e31\u0e15\u0e42\u0e19\u0e21\u0e31\u0e15\u0e34\u0e44\u0e14\u0e49<\/td>\n<\/tr>\n<tr>\n<th>\u0e1b\u0e31\u0e08\u0e08\u0e31\u0e22\u0e01\u0e33\u0e25\u0e31\u0e07\u0e44\u0e1f\u0e1f\u0e49\u0e32\u0e02\u0e32\u0e40\u0e02\u0e49\u0e32<\/th>\n<td>&gt;0.99 at 100% load<\/td>\n<\/tr>\n<tr>\n<th>\u0e41\u0e23\u0e07\u0e14\u0e31\u0e19\u0e44\u0e1f\u0e1f\u0e49\u0e32\u0e02\u0e32\u0e2d\u0e2d\u0e01<\/th>\n<td>380 \/ 400 \/ 415VAC, phase-to-phase<\/td>\n<\/tr>\n<tr>\n<th>\u0e01\u0e32\u0e23\u0e04\u0e27\u0e1a\u0e04\u0e38\u0e21\u0e41\u0e23\u0e07\u0e14\u0e31\u0e19\u0e44\u0e1f\u0e1f\u0e49\u0e32 AC<\/th>\n<td>\u00b10.3%<\/td>\n<\/tr>\n<tr>\n<th>Synchronized Frequency<\/th>\n<td>46Hz-54Hz or 56Hz-64Hz<\/td>\n<\/tr>\n<tr>\n<th>Battery Mode Frequency<\/th>\n<td>50 Hz \u00b10.1 Hz \u0e2b\u0e23\u0e37\u0e2d 60 Hz \u00b10.1 Hz<\/td>\n<\/tr>\n<tr>\n<th>Current Crest Ratio<\/th>\n<td>3:1 max<\/td>\n<\/tr>\n<tr>\n<th>THD \u0e02\u0e2d\u0e07\u0e2a\u0e31\u0e0d\u0e0d\u0e32\u0e13\u0e2d\u0e2d\u0e01<\/th>\n<td>THD \u22641% \u0e40\u0e21\u0e37\u0e48\u0e2d\u0e43\u0e0a\u0e49\u0e42\u0e2b\u0e25\u0e14\u0e41\u0e1a\u0e1a\u0e40\u0e0a\u0e34\u0e07\u0e40\u0e2a\u0e49\u0e19; THD \u22642% \u0e40\u0e21\u0e37\u0e48\u0e2d\u0e43\u0e0a\u0e49\u0e42\u0e2b\u0e25\u0e14\u0e41\u0e1a\u0e1a\u0e44\u0e21\u0e48\u0e40\u0e0a\u0e34\u0e07\u0e40\u0e2a\u0e49\u0e19<\/td>\n<\/tr>\n<tr>\n<th>\u0e40\u0e27\u0e25\u0e32\u0e42\u0e2d\u0e19<\/th>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<th>Overload Capability<\/th>\n<td>100%-110%: 60 min; 110%-125%: 10 min; 125%-150%: 1 min; &gt;150%: immediate protection<\/td>\n<\/tr>\n<tr>\n<th>\u0e1b\u0e23\u0e30\u0e2a\u0e34\u0e17\u0e18\u0e34\u0e20\u0e32\u0e1e<\/th>\n<td>&gt;96.5% in AC mode; &gt;96.5% in battery mode<\/td>\n<\/tr>\n<tr>\n<th>\u0e08\u0e33\u0e19\u0e27\u0e19\u0e41\u0e1a\u0e15\u0e40\u0e15\u0e2d\u0e23\u0e35\u0e48<\/th>\n<td>32-40 batteries, adjustable<\/td>\n<\/tr>\n<tr>\n<th>Max Charging Current<\/th>\n<td>2-36A \u00b110%, \u0e15\u0e31\u0e49\u0e07\u0e04\u0e48\u0e32\u0e25\u0e48\u0e27\u0e07\u0e2b\u0e19\u0e49\u0e32 2A<\/td>\n<\/tr>\n<tr>\n<th>\u0e02\u0e19\u0e32\u0e14<\/th>\n<td>1000 \u00d7 430 \u00d7 1200 \u0e21\u0e21.<\/td>\n<\/tr>\n<tr>\n<th>\u0e19\u0e49\u0e33\u0e2b\u0e19\u0e31\u0e01\u0e2a\u0e38\u0e17\u0e18\u0e34<\/th>\n<td>200 \u0e01\u0e34\u0e42\u0e25\u0e01\u0e23\u0e31\u0e21<\/td>\n<\/tr>\n<tr>\n<th>\u0e2d\u0e38\u0e13\u0e2b\u0e20\u0e39\u0e21\u0e34\u0e01\u0e32\u0e23\u0e17\u0e33\u0e07\u0e32\u0e19<\/th>\n<td>0\u00b0C-40\u00b0C<\/td>\n<\/tr>\n<tr>\n<th>\u0e04\u0e27\u0e32\u0e21\u0e0a\u0e37\u0e49\u0e19\u0e2a\u0e31\u0e21\u0e1e\u0e31\u0e17\u0e18\u0e4c<\/th>\n<td>&lt;95%, non-condensing<\/td>\n<\/tr>\n<tr>\n<th>\u0e40\u0e2a\u0e35\u0e22\u0e07\u0e23\u0e1a\u0e01\u0e27\u0e19<\/th>\n<td>&lt;70dB @ 1m<\/td>\n<\/tr>\n<tr>\n<th>Altitude<\/th>\n<td>&lt;1000m<\/td>\n<\/tr>\n<tr>\n<th>\u0e2d\u0e34\u0e19\u0e40\u0e17\u0e2d\u0e23\u0e4c\u0e40\u0e1f\u0e0b\u0e01\u0e32\u0e23\u0e2a\u0e37\u0e48\u0e2d\u0e2a\u0e32\u0e23<\/th>\n<td>RS232 \/ USB; optional SNMP management support<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u0e04\u0e33\u0e16\u0e32\u0e21\u0e17\u0e35\u0e48\u0e1e\u0e1a\u0e1a\u0e48\u0e2d\u0e22<\/h3>\n<h4>What is the DAXIN ENERGY EX3C3 100kVA online UPS used for?<\/h4>\n<p>The DAXIN ENERGY EX3C3 100kVA online UPS is used for data centers, telecom rooms,<br \/>\nindustrial facilities, commercial buildings and critical infrastructure that require<br \/>\nstable three-phase backup power and continuous power protection.<\/p>\n<h4>Is the EX3C3 100kVA UPS a true online double-conversion UPS?<\/h4>\n<p>Yes. The EX3C3 100kVA UPS uses true online double-conversion technology to provide<br \/>\nstable voltage, stable frequency and clean sine wave output for sensitive equipment.<\/p>\n<h4>Does the EX3C3 100kVA UPS support generator input?<\/h4>\n<p>Yes. The UPS is compatible with generator input. For stable operation, the generator<br \/>\ncapacity is recommended to be at least 2 times the UPS capacity.<\/p>\n<h4>Can the EX3C3 100kVA UPS be monitored remotely?<\/h4>\n<p>Yes. The UPS supports RS232 and USB communication, with optional SNMP network<br \/>\nmanagement for remote monitoring, alarm notification and power management.<\/p>\n<h4>What applications are suitable for a 100kVA three-phase online UPS?<\/h4>\n<p>A 100kVA three-phase online UPS is suitable for data centers, server rooms, telecom<br \/>\nsystems, manufacturing equipment, control rooms, security systems and other<br \/>\nmission-critical electrical loads.<\/p>\n<h4>What is the output capacity of the EX3C3 100kVA UPS?<\/h4>\n<p>The EX3C3 100kVA model provides 100kVA \/ 100kW output capacity, making it suitable<br \/>\nfor high-power industrial and commercial backup power applications.<\/p>\n<h4>Does the UPS provide zero transfer time?<\/h4>\n<p>Yes. As a true online UPS, the EX3C3 100kVA provides 0ms transfer time, helping<br \/>\nprotect critical loads from power interruption, voltage fluctuation and grid instability.<\/p>\n<h4>What battery configuration does the EX3C3 100kVA UPS support?<\/h4>\n<p>The EX3C3 100kVA UPS supports 32-40 batteries, adjustable according to project<br \/>\nrequirements and backup time needs.<\/p>\n<figure id=\"attachment_2232\" class=\"wp-caption aligncenter\" style=\"width: 982px;\" aria-describedby=\"caption-attachment-2232\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-2232\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/daxin-sitewide-p2314-detail-01.webp\" alt=\"EX3C3 100kVA Online UPS | Three-Phase UPS - DAXIN ENERGY technical detail 1 by DAXIN ENERGY\" width=\"982\" height=\"664\" \/><figcaption id=\"caption-attachment-2232\" class=\"wp-caption-text\">\u0e04\u0e38\u0e13\u0e2a\u0e21\u0e1a\u0e31\u0e15\u0e34\u0e2b\u0e25\u0e31\u0e01\u0e02\u0e2d\u0e07 UPS \u0e2d\u0e2d\u0e19\u0e44\u0e25\u0e19\u0e4c DAXIN ENERGY \u0e44\u0e14\u0e49\u0e41\u0e01\u0e48 \u0e41\u0e2b\u0e25\u0e48\u0e07\u0e08\u0e48\u0e32\u0e22\u0e44\u0e1f\u0e17\u0e35\u0e48\u0e40\u0e2a\u0e16\u0e35\u0e22\u0e23 \u0e0a\u0e48\u0e27\u0e07\u0e41\u0e23\u0e07\u0e14\u0e31\u0e19\u0e44\u0e1f\u0e1f\u0e49\u0e32\u0e17\u0e35\u0e48\u0e01\u0e27\u0e49\u0e32\u0e07 \u0e1b\u0e23\u0e30\u0e2b\u0e22\u0e31\u0e14\u0e1e\u0e25\u0e31\u0e07\u0e07\u0e32\u0e19 \u0e41\u0e25\u0e30\u0e43\u0e0a\u0e49\u0e07\u0e32\u0e19\u0e07\u0e48\u0e32\u0e22.<\/figcaption><\/figure>","protected":false},"excerpt":{"rendered":"<p>DAXIN ENERGY EX3C3 100kVA three-phase online UPS provides 100kW true double-conversion backup power for data centers, telecom facilities, industrial equipment and commercial buildings. It features high efficiency, wide input voltage range, 0ms transfer time, generator compatibility and optional SNMP remote monitoring.<\/p>","protected":false},"featured_media":4089,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[98,104],"product_tag":[],"class_list":["post-2314","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-high-frequency-ups","product_cat-hf-3-3-phase-ups","first","instock","downloadable","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/th\/wp-json\/wp\/v2\/product\/2314","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/th\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/th\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/th\/wp-json\/wp\/v2\/comments?post=2314"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/th\/wp-json\/wp\/v2\/media\/4089"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/th\/wp-json\/wp\/v2\/media?parent=2314"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/th\/wp-json\/wp\/v2\/product_brand?post=2314"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/th\/wp-json\/wp\/v2\/product_cat?post=2314"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/th\/wp-json\/wp\/v2\/product_tag?post=2314"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}