{"id":3015,"date":"2026-08-02T15:28:12","date_gmt":"2026-08-02T15:28:12","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=3015"},"modified":"2026-08-17T17:17:25","modified_gmt":"2026-08-17T09:17:25","slug":"daxin-rm33-200kva-system-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/pt\/product\/daxin-rm33-200kva-system-ups\/","title":{"rendered":"200kVA Modular Online UPS | DAXIN RM33"},"content":{"rendered":"<h2>What Is the DAXIN RM33 200kVA Modular Online UPS?<\/h2>\n<p>The DAXIN RM33 200kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.<\/p>\n<p>Its modular cabinet architecture integrates power modules, system control, protection and service access within a scalable UPS platform. The reference configuration provides 200kW cabinet capacity and supports external battery packs for project-specific backup requirements.<\/p>\n<p>The RM33 series supports 3 \u00d7 380\/400\/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.<\/p>\n<p>Final installed capacity, power-module configuration, battery runtime, redundancy architecture, communications and project accessories should be confirmed against the approved DAXIN technical proposal.<\/p>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>RM33-200kVA<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Modelo<\/td>\n<td><strong>RM33-200kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>UPS Type<\/td>\n<td>Modular Online UPS<\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>Three-Phase Input \/ Three-Phase Output<\/td>\n<\/tr>\n<tr>\n<td>Cabinet Capacity<\/td>\n<td><strong>200kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Tipo de bateria<\/td>\n<td>External Battery Pack<\/td>\n<\/tr>\n<tr>\n<td>Battery Cabinet Capacity<\/td>\n<td>20kVA \/ 20kW<\/td>\n<\/tr>\n<tr>\n<td>Optional Battery Cabinets<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o de entrada<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia de entrada<\/td>\n<td>50\/60Hz Auto-Detect<\/td>\n<\/tr>\n<tr>\n<td>Faixa de frequ\u00eancia de entrada<\/td>\n<td>40\u201370Hz<\/td>\n<\/tr>\n<tr>\n<td>Fator de pot\u00eancia de entrada<\/td>\n<td>\u22650.99 @ 100% Load<\/td>\n<\/tr>\n<tr>\n<td>Input Current THDi<\/td>\n<td>&lt;2% @ 100% Load<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o de sa\u00edda<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Static Voltage Stability<\/td>\n<td>\u2264\u00b10.3% Typical Load<\/td>\n<\/tr>\n<tr>\n<td>Dynamic Voltage Stability<\/td>\n<td>\u2264\u00b13% Typical Load<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia de sa\u00edda<\/td>\n<td>50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>THD de sa\u00edda<\/td>\n<td>\u22641% Linear \/ \u22642% Non-linear<\/td>\n<\/tr>\n<tr>\n<td>Efici\u00eancia<\/td>\n<td><strong>Up to 96.5%<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Dimens\u00f5es<\/td>\n<td><strong>1100 \u00d7 600 \u00d7 2010mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Peso l\u00edquido<\/td>\n<td><strong>282kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Temperatura de opera\u00e7\u00e3o<\/td>\n<td>0\u201340\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Altitude<\/td>\n<td>&lt;1000m Rated Power<\/td>\n<\/tr>\n<tr>\n<td>\u00cdndice de prote\u00e7\u00e3o<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Comunica\u00e7\u00e3o<\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td>Network Management<\/td>\n<td>SNMP opcional<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4939\" aria-describedby=\"caption-attachment-4939\" style=\"width: 812px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4939\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp\" alt=\"DAXIN RM33 Modular Online UPS Technical Specifications\" width=\"812\" height=\"1935\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp 812w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-126x300.webp 126w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-430x1024.webp 430w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-768x1830.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-645x1536.webp 645w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-5x12.webp 5w\" sizes=\"auto, (max-width: 812px) 100vw, 812px\" \/><figcaption id=\"caption-attachment-4939\" class=\"wp-caption-text\">Technical specifications for the DAXIN RM33 three-phase modular online UPS series.<\/figcaption><\/figure><figcaption>Product View for DAXIN RM33-200kVA Modular UPS System Cabinet.<\/figcaption><\/figure>\n<h2>Principais benef\u00edcios<\/h2>\n<ul>\n<li><strong>Scalable Modular Architecture:<\/strong>\u00a0Modular UPS design supports flexible capacity planning and future system expansion.<\/li>\n<li><strong>200kW Cabinet Capacity:<\/strong>\u00a0The RM33-200kVA reference cabinet is designed for large three-phase critical-power applications.<\/li>\n<li><strong>Three-Phase Power Protection:<\/strong>\u00a0Supports 3 \u00d7 380\/400\/415VAC three-phase input and output for data center, telecom and industrial electrical systems.<\/li>\n<li><strong>Low Input Harmonic Distortion:<\/strong>\u00a0Input current THDi below 2% at full load helps reduce upstream electrical impact.<\/li>\n<li><strong>High Input Power Factor:<\/strong>\u00a0Input power factor is at least 0.99 at 100% load.<\/li>\n<li><strong>High Efficiency:<\/strong>\u00a0System efficiency is specified at up to 96.5%.<\/li>\n<li><strong>External Battery Configuration:<\/strong>\u00a0Battery systems can be engineered according to required backup runtime and project requirements.<\/li>\n<li><strong>Monitoramento remoto:<\/strong>\u00a0RS-232\/USB communication is supported, with optional SNMP network management.<\/li>\n<\/ul>\n<h2><\/h2>\n<h2>What Is a Modular UPS System?<\/h2>\n<p>A modular UPS system uses multiple power modules within a common cabinet architecture instead of relying on a single fixed-capacity power stage.<\/p>\n<p>This approach allows UPS capacity, maintenance strategy and redundancy architecture to be planned according to the critical load and future expansion requirements.<\/p>\n<p>The DAXIN RM33 series combines modular power architecture with centralized control, external battery systems and network-management options for scalable critical-power applications.<\/p>\n<h2>Why Choose a 200kVA Modular UPS for a Data Center?<\/h2>\n<p>A modular UPS can help data center operators align installed power capacity with the actual critical load while preserving a path for future expansion and redundancy planning.<\/p>\n<p>The DAXIN RM33-200kVA combines three-phase online power protection, modular system architecture, external battery configuration and optional network monitoring for data center and mission-critical infrastructure applications.<\/p>\n<p>Final system sizing should consider the IT load in kW and kVA, power factor, redundancy target, expected expansion, required battery autonomy and upstream electrical architecture.<\/p>\n<h2>Aplica\u00e7\u00f5es t\u00edpicas<\/h2>\n<ul>\n<li>Centros de dados e salas de servidores<\/li>\n<li>Telecom core facilities and network infrastructure<\/li>\n<li>Industrial automation and manufacturing plants<\/li>\n<li>Financial and banking facilities<\/li>\n<li>Healthcare and medical infrastructure<\/li>\n<li>Transportation and public infrastructure<\/li>\n<li>Enterprise IT facilities<\/li>\n<li>Other scalable mission-critical power systems<\/li>\n<\/ul>\n<h2>Sele\u00e7\u00e3o e Planejamento do Projeto<\/h2>\n<p>Antes de fazer o pedido, verifique se a pot\u00eancia nominal exata, a fase de entrada\/sa\u00edda, a tens\u00e3o, a frequ\u00eancia, o fator de pot\u00eancia, a tens\u00e3o da bateria, o tempo de opera\u00e7\u00e3o, o bypass, os recursos de comunica\u00e7\u00e3o, as dimens\u00f5es, os limites ambientais e o m\u00e9todo de instala\u00e7\u00e3o correspondem ao modelo selecionado e aos desenhos do projeto.<\/p>\n<h2>Perguntas frequentes<\/h2>\n<h3>Esse produto pode ser configurado para um projeto espec\u00edfico?<\/h3>\n<p>Sim. A configura\u00e7\u00e3o el\u00e9trica, a autonomia da bateria, os sistemas de comunica\u00e7\u00e3o, o desvio, a disposi\u00e7\u00e3o dos gabinetes e os acess\u00f3rios do projeto podem ser analisados em fun\u00e7\u00e3o dos requisitos do local.<\/p>\n<h3>Todas as classifica\u00e7\u00f5es t\u00e9cnicas s\u00e3o v\u00e1lidas para toda a s\u00e9rie?<\/h3>\n<p>N\u00e3o. As especifica\u00e7\u00f5es e fun\u00e7\u00f5es variam de acordo com o modelo e a configura\u00e7\u00e3o. Utilize a ficha t\u00e9cnica espec\u00edfica do projeto como refer\u00eancia definitiva.<\/p>\n<h3>A DAXIN ENERGY pode oferecer suporte na sele\u00e7\u00e3o de sistemas?<\/h3>\n<p>Sim. Forne\u00e7a a lista de cargas, a fase e a tens\u00e3o, o tempo de opera\u00e7\u00e3o necess\u00e1rio, a meta de redund\u00e2ncia, os requisitos de comunica\u00e7\u00e3o e o ambiente de instala\u00e7\u00e3o.<\/p>\n<h2>Solicitar uma configura\u00e7\u00e3o de projeto<\/h2>\n<p>Envie os dados de carga, o esquema unifilar, o tempo de backup necess\u00e1rio e as condi\u00e7\u00f5es do local para receber uma proposta personalizada de UPS ou bateria.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"5difiu\" data-start=\"8307\" data-end=\"8341\">What is the DAXIN RM33-200kVA?<\/h3>\n<blockquote data-start=\"8343\" data-end=\"8460\">\n<p data-start=\"8345\" data-end=\"8460\">The DAXIN RM33-200kVA is a three-phase modular online UPS system designed for scalable critical-power applications.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"152my1e\" data-start=\"8462\" data-end=\"8495\">What is the cabinet capacity?<\/h3>\n<blockquote data-start=\"8497\" data-end=\"8601\">\n<p data-start=\"8499\" data-end=\"8601\">The supplied RM33 series specification lists 200kW cabinet capacity for the RM33-200kVA configuration.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"zp921o\" data-start=\"8603\" data-end=\"8653\">What input and output voltage does it support?<\/h3>\n<blockquote data-start=\"8655\" data-end=\"8739\">\n<p data-start=\"8657\" data-end=\"8739\">The reference specification lists 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"18hlpeq\" data-start=\"8741\" data-end=\"8786\">What are the input power factor and THDi?<\/h3>\n<blockquote data-start=\"8788\" data-end=\"8908\">\n<p data-start=\"8790\" data-end=\"8908\">The reference specification lists an input power factor of at least 0.99 at full load and input current THDi below 2%.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"1xhhnr9\" data-start=\"8910\" data-end=\"8954\">Does the RM33 support remote monitoring?<\/h3>\n<blockquote data-start=\"8956\" data-end=\"9056\">\n<p data-start=\"8958\" data-end=\"9056\">Yes. RS-232\/USB communication is supported, and SNMP network management is available as an option.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"16gc40b\" data-start=\"9058\" data-end=\"9110\">How should the RM33-200kVA system be configured?<\/h3>\n<blockquote data-start=\"9112\" data-end=\"9306\">\n<p data-start=\"9114\" data-end=\"9306\">Final configuration should consider the critical load, required redundancy, future expansion, battery runtime, electrical distribution, communication requirements and installation environment.<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p>The DAXIN RM33 200kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom and industrial facilities. Its modular architecture supports flexible capacity planning, centralized control, external battery configurations and optional SNMP monitoring, with efficiency up to 96.5%.<\/p>","protected":false},"featured_media":4936,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,100],"product_tag":[],"class_list":["post-3015","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-ups-system-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product\/3015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/comments?post=3015"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/media\/4936"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/media?parent=3015"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product_brand?post=3015"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product_cat?post=3015"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product_tag?post=3015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}