{"id":2960,"date":"2026-08-02T15:23:02","date_gmt":"2026-08-02T15:23:02","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=2960"},"modified":"2026-08-15T21:42:09","modified_gmt":"2026-08-15T13:42:09","slug":"daxin-3h3-80kva-lf33-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/pt\/product\/daxin-3h3-80kva-lf33-ups\/","title":{"rendered":"80kVA Low-Frequency Online UPS | DAXIN 3H3"},"content":{"rendered":"<h2>What Is the DAXIN 3H3 80kVA 3\/3 Phase Online UPS?<\/h2>\n<p>The DAXIN 3H3 80kVA is an 80kVA\/64kW low-frequency online UPS designed for critical applications requiring three-phase input and three-phase output power protection.<\/p>\n<p>Sua arquitetura trif\u00e1sica 3\/3 destina-se a instala\u00e7\u00f5es nas quais tanto o fornecimento de energia el\u00e9trica de entrada quanto as cargas cr\u00edticas protegidas operam com energia trif\u00e1sica.<\/p>\n<p>A configura\u00e7\u00e3o de refer\u00eancia suporta entrada e sa\u00edda trif\u00e1sicas de 380\/400\/415 VCA, transfer\u00eancia da rede el\u00e9trica para a bateria em 0 ms e efici\u00eancia superior a 90%.<\/p>\n<p>A configura\u00e7\u00e3o da bateria, o circuito de desvio, as comunica\u00e7\u00f5es, os requisitos de redund\u00e2ncia e outros par\u00e2metros do projeto devem ser confirmados de acordo com a carga conectada, o tempo de backup necess\u00e1rio e a proposta t\u00e9cnica aprovada da DAXIN.<\/p>\n<h2>Principais benef\u00edcios<\/h2>\n<ul>\n<li><strong>80kVA \/ 64kW Capacity:<\/strong>\u00a0Designed for high-capacity critical three-phase loads in industrial and infrastructure applications.<\/li>\n<li><strong>Arquitetura trif\u00e1sica:<\/strong>\u00a0Three-phase input and three-phase output support large three-phase electrical systems.<\/li>\n<li><strong>Projeto de UPS de baixa frequ\u00eancia:<\/strong>\u00a0Intended for demanding industrial and infrastructure critical-power applications.<\/li>\n<li><strong>Prote\u00e7\u00e3o de energia online:<\/strong>\u00a0Fornece energia tratada para cargas sens\u00edveis e essenciais \u00e0 opera\u00e7\u00e3o.<\/li>\n<li><strong>Transfer\u00eancia da rede el\u00e9trica para a bateria em 0 ms:<\/strong>\u00a0Mant\u00e9m a pot\u00eancia de sa\u00edda durante a transi\u00e7\u00e3o da rede el\u00e9trica para a bateria, de acordo com as especifica\u00e7\u00f5es de refer\u00eancia.<\/li>\n<li><strong>Sistema de bateria configur\u00e1vel:<\/strong>\u00a0Battery configuration and runtime can be engineered according to load and backup-time requirements.<\/li>\n<li><strong>Monitoramento e prote\u00e7\u00e3o:<\/strong>\u00a0As fun\u00e7\u00f5es de exibi\u00e7\u00e3o, alarme, prote\u00e7\u00e3o e comunica\u00e7\u00e3o auxiliam na opera\u00e7\u00e3o e manuten\u00e7\u00e3o do sistema.<\/li>\n<li><strong>Configura\u00e7\u00e3o baseada em projeto:<\/strong>\u00a0\u00c9 necess\u00e1rio verificar se a configura\u00e7\u00e3o selecionada possui recursos de paralelismo, redund\u00e2ncia, desvio e comunica\u00e7\u00e3o.<\/li>\n<\/ul>\n<h2>O que significa \u201c3\/3 fases\u201d em um no-break?<\/h2>\n<p>Um no-break trif\u00e1sico 3\/3 utiliza energia CA trif\u00e1sica na entrada e fornece energia CA trif\u00e1sica na sa\u00edda.<\/p>\n<p>This configuration is commonly used for medium- and high-capacity critical loads in data centers, industrial facilities, telecom infrastructure, healthcare systems and other facilities operating three-phase electrical equipment.<\/p>\n<p>The DAXIN 3H3 80kVA uses this three-phase input and three-phase output architecture for critical-power applications requiring 80kVA-class UPS capacity.<\/p>\n<h2>What Loads Can an 80kVA UPS Support?<\/h2>\n<p>The DAXIN 3H3 80kVA reference model is rated at 80kVA \/ 64kW. The actual equipment that can be supported depends on the combined active power, power factor, startup or peak demand and required operating margin of the connected loads.<\/p>\n<p>UPS sizing should be based on measured or calculated load data rather than equipment quantity alone. Future expansion and required battery runtime should also be considered during system design.<\/p>\n<h2>\nEspecifica\u00e7\u00f5es principais<br \/>\nDAXIN 3H3 80kVA Key Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Par\u00e2metro<\/th>\n<th>3H3-80kVA<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Capacidade nominal<\/strong><\/td>\n<td><strong>80kVA \/ 64kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Fase<\/td>\n<td>Three-Phase Input \/ Three-Phase Output<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o de entrada<\/td>\n<td>3\u00d7380 \/ 400 \/ 415VAC<\/td>\n<\/tr>\n<tr>\n<td>Faixa de tens\u00e3o de entrada<\/td>\n<td>285\u2013475VAC<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia de entrada<\/td>\n<td>46\u201354Hz @ 50Hz; 56\u201364Hz @ 60Hz<\/td>\n<\/tr>\n<tr>\n<td>Tens\u00e3o de sa\u00edda<\/td>\n<td>380 \/ 400 \/ 415VAC<\/td>\n<\/tr>\n<tr>\n<td>Frequ\u00eancia no modo de bateria<\/td>\n<td>50\/60Hz \u00b10.1Hz<\/td>\n<\/tr>\n<tr>\n<td>THD de sa\u00edda<\/td>\n<td>&lt;3% Linear \/ &lt;5% Non-linear<\/td>\n<\/tr>\n<tr>\n<td>Transfer\u00eancia da rede el\u00e9trica para a bateria<\/td>\n<td>0 ms<\/td>\n<\/tr>\n<tr>\n<td>Efici\u00eancia<\/td>\n<td>&gt;90%<\/td>\n<\/tr>\n<tr>\n<td>Tipo de bateria<\/td>\n<td>Sealed Lead-Acid, Maintenance-Free<\/td>\n<\/tr>\n<tr>\n<td>Quantidade de baterias<\/td>\n<td>29 \/ 30 \/ 31 \/ 32 pcs, 12V Series<\/td>\n<\/tr>\n<tr>\n<td>Dimens\u00f5es<\/td>\n<td><strong>975 \u00d7 554 \u00d7 1286 mm<\/strong>*<\/td>\n<\/tr>\n<tr>\n<td>Peso l\u00edquido<\/td>\n<td><strong>400 kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Temperatura de opera\u00e7\u00e3o<\/td>\n<td>0\u201355\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Umidade relativa<\/td>\n<td>&lt;95%, sem condensa\u00e7\u00e3o<\/td>\n<\/tr>\n<tr>\n<td>Altitude de opera\u00e7\u00e3o<\/td>\n<td>&lt;1.000 m<\/td>\n<\/tr>\n<tr>\n<td>Comunica\u00e7\u00e3o<\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td>SNMP<\/td>\n<td>Opcional<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\nVis\u00f5es do produto e refer\u00eancia t\u00e9cnica<\/h2>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4909\" aria-describedby=\"caption-attachment-4909\" style=\"width: 970px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4909\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS.webp\" alt=\"Especifica\u00e7\u00f5es t\u00e9cnicas do no-break online DAXIN 3H3-60 kVA, trif\u00e1sico 3\/3 fases\" width=\"970\" height=\"914\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS.webp 970w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS-300x283.webp 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS-768x724.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/3H3-60kVA-CS-13x12.webp 13w\" sizes=\"auto, (max-width: 970px) 100vw, 970px\" \/><figcaption id=\"caption-attachment-4909\" class=\"wp-caption-text\">Especifica\u00e7\u00f5es t\u00e9cnicas do no-break online DAXIN 3H3-60kVA trif\u00e1sico 3\/3.<\/figcaption><\/figure><\/figure>\n<figure class=\"wp-block-image size-full\"><figcaption>Control Panel and Front Detail for DAXIN 3H3 80kVA Low-Frequency 3\/3 Phase UPS.<\/figcaption><\/figure>\n<h2>Aplica\u00e7\u00f5es t\u00edpicas<\/h2>\n<ul>\n<li>Centros de dados e instala\u00e7\u00f5es de servidores<\/li>\n<li>Industrial plants and manufacturing systems<\/li>\n<li>Power and utility infrastructure<\/li>\n<li>Telecom core facilities<\/li>\n<li>Hospitals and critical healthcare systems<\/li>\n<li>Transportation and tunnel infrastructure<\/li>\n<li>Commercial and public infrastructure<\/li>\n<li>Other high-capacity three-phase critical loads<\/li>\n<\/ul>\n<h2>How to Select an 80kVA Three-Phase UPS<\/h2>\n<p>Selecione o no-break de acordo com a carga real conectada em kW e kVA, a tens\u00e3o de entrada e sa\u00edda, o fator de pot\u00eancia, a demanda de partida ou de pico, o tempo de autonomia necess\u00e1rio, a configura\u00e7\u00e3o da bateria, os requisitos de bypass, a arquitetura de redund\u00e2ncia, as interfaces de comunica\u00e7\u00e3o e o ambiente de instala\u00e7\u00e3o.<\/p>\n<p>No caso de um no-break trif\u00e1sico (3\/3), verifique se tanto a rede el\u00e9trica do local quanto as cargas cr\u00edticas protegidas exigem alimenta\u00e7\u00e3o trif\u00e1sica.<\/p>\n<p>Forne\u00e7a \u00e0 DAXIN ENERGY a lista de carga, o diagrama unifilar, a tens\u00e3o no local, o tempo de opera\u00e7\u00e3o necess\u00e1rio, os requisitos de redund\u00e2ncia, as interfaces de comunica\u00e7\u00e3o e as condi\u00e7\u00f5es de instala\u00e7\u00e3o para a configura\u00e7\u00e3o do projeto.<\/p>\n<h2>\nSele\u00e7\u00e3o e Planejamento do Projeto<\/h2>\n<p>Antes de fazer o pedido, verifique se a pot\u00eancia nominal exata, a fase de entrada\/sa\u00edda, a tens\u00e3o, a frequ\u00eancia, o fator de pot\u00eancia, a tens\u00e3o da bateria, o tempo de opera\u00e7\u00e3o, o bypass, os recursos de comunica\u00e7\u00e3o, as dimens\u00f5es, os limites ambientais e o m\u00e9todo de instala\u00e7\u00e3o correspondem ao modelo selecionado e aos desenhos do projeto.<\/p>\n<h2>Perguntas frequentes<\/h2>\n<h3>Esse produto pode ser configurado para um projeto espec\u00edfico?<\/h3>\n<p>Sim. A configura\u00e7\u00e3o el\u00e9trica, a autonomia da bateria, os sistemas de comunica\u00e7\u00e3o, o desvio, a disposi\u00e7\u00e3o dos gabinetes e os acess\u00f3rios do projeto podem ser analisados em fun\u00e7\u00e3o dos requisitos do local.<\/p>\n<h3>Todas as classifica\u00e7\u00f5es t\u00e9cnicas s\u00e3o v\u00e1lidas para toda a s\u00e9rie?<\/h3>\n<p>N\u00e3o. As especifica\u00e7\u00f5es e fun\u00e7\u00f5es variam de acordo com o modelo e a configura\u00e7\u00e3o. Utilize a ficha t\u00e9cnica espec\u00edfica do projeto como refer\u00eancia definitiva.<\/p>\n<h3>A DAXIN ENERGY pode oferecer suporte na sele\u00e7\u00e3o de sistemas?<\/h3>\n<p>Sim. Forne\u00e7a a lista de cargas, a fase e a tens\u00e3o, o tempo de opera\u00e7\u00e3o necess\u00e1rio, a meta de redund\u00e2ncia, os requisitos de comunica\u00e7\u00e3o e o ambiente de instala\u00e7\u00e3o.<\/p>\n<h2>Solicitar uma configura\u00e7\u00e3o de projeto<\/h2>\n<p>Envie os dados de carga, o esquema unifilar, o tempo de backup necess\u00e1rio e as condi\u00e7\u00f5es do local para receber uma proposta personalizada de UPS ou bateria.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"4zmkr8\" data-start=\"8543\" data-end=\"8597\">What is the rated capacity of the DAXIN 3H3 80kVA?<\/h3>\n<p data-start=\"8599\" data-end=\"8648\">The reference model is rated at 80kVA \/ 64kW.<\/p>\n<h3 data-section-id=\"1qek9s9\" data-start=\"8650\" data-end=\"8679\">O que significa \u201c3\/3 fases\u201d?<\/h3>\n<p data-start=\"8681\" data-end=\"8757\">Isso significa que o no-break utiliza entrada trif\u00e1sica e fornece sa\u00edda trif\u00e1sica.<\/p>\n<h3 data-section-id=\"1gp3azk\" data-start=\"8759\" data-end=\"8806\">Qual \u00e9 o tempo de transi\u00e7\u00e3o da rede el\u00e9trica para a bateria?<\/h3>\n<p data-start=\"8808\" data-end=\"8876\">A especifica\u00e7\u00e3o de refer\u00eancia indica um tempo de transfer\u00eancia da rede el\u00e9trica para a bateria de 0 ms.<\/p>\n<h3 data-section-id=\"1b2caab\" data-start=\"8878\" data-end=\"8923\">Qual \u00e9 a tens\u00e3o de sa\u00edda compat\u00edvel com o no-break?<\/h3>\n<p data-start=\"8925\" data-end=\"9000\">A configura\u00e7\u00e3o de refer\u00eancia suporta sa\u00edda trif\u00e1sica de 380\/400\/415 VCA.<\/p>\n<h3 data-section-id=\"1f4wgjv\" data-start=\"9002\" data-end=\"9039\">How should an 80kVA UPS be sized?<\/h3>\n<p data-start=\"9041\" data-end=\"9199\">UPS sizing should consider actual load in kW and kVA, power factor, peak demand, future expansion, required operating margin and backup-time requirements.<\/p>\n<h3 data-section-id=\"11nrlqr\" data-start=\"9201\" data-end=\"9251\">Can the 80kVA UPS support parallel redundancy?<\/h3>\n<p data-start=\"9253\" data-end=\"9419\">Os recursos de paralelismo e redund\u00e2ncia dependem da configura\u00e7\u00e3o selecionada e devem ser verificados em rela\u00e7\u00e3o \u00e0s especifica\u00e7\u00f5es t\u00e9cnicas aprovadas antes do projeto do sistema.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN 3H3 80kVA is an 80kVA\/64kW low-frequency 3\/3 phase online UPS designed for high-capacity critical power applications requiring three-phase input and three-phase output. Featuring online power protection, 0ms mains-to-battery transfer and project-configurable battery, bypass and monitoring options, it is suitable for data centers, industrial facilities, power infrastructure, transportation, healthcare and other critical three-phase loads.<\/p>","protected":false},"featured_media":4908,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[109,99,97],"product_tag":[],"class_list":["post-2960","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-low-frequency-3-3-phase-ups","product_cat-low-frequency-ups","product_cat-ups-solutions","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product\/2960","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/comments?post=2960"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/media\/4908"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/media?parent=2960"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product_brand?post=2960"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product_cat?post=2960"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/pt\/wp-json\/wp\/v2\/product_tag?post=2960"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}