{"id":766,"date":"2026-05-05T09:47:33","date_gmt":"2026-05-05T09:47:33","guid":{"rendered":"http:\/\/btrytech.com\/?post_type=product&#038;p=766"},"modified":"2026-05-05T09:47:33","modified_gmt":"2026-05-05T09:47:33","slug":"11-h-2kva-online-ups-standard-model-power-supply-double-conversion-uninterruptible-power-system","status":"publish","type":"product","link":"https:\/\/btrytech.com\/id\/product\/11-h-2kva-online-ups-standard-model-power-supply-double-conversion-uninterruptible-power-system\/","title":{"rendered":"11-H 2kVA UPS Online (Model Standar) Catu Daya | Sistem Catu Daya Tak Terputus Konversi Ganda"},"content":{"rendered":"<p>The 11-H 2kVA Online UPS uses advanced double-conversion technology to provide stable, clean, and uninterrupted power for critical equipment. With high reliability and performance, it is an ideal power protection solution for small to medium-scale applications.<\/p>\n<p data-start=\"884\" data-end=\"1053\">Widely used in government, finance, telecommunications, education, transportation, meteorology, broadcasting, taxation, healthcare, and energy industries.<\/p>\n<ul data-start=\"1384\" data-end=\"1990\">\n<li data-section-id=\"2z246h\" data-start=\"1384\" data-end=\"1452\">True double-conversion online technology with zero transfer time<\/li>\n<li data-section-id=\"10854km\" data-start=\"1453\" data-end=\"1500\">Microprocessor control for high reliability<\/li>\n<li data-section-id=\"149750u\" data-start=\"1501\" data-end=\"1540\">Input Power Factor Correction (PFC)<\/li>\n<li data-section-id=\"1rtebr0\" data-start=\"1541\" data-end=\"1574\">Output power factor up to 0.9<\/li>\n<li data-section-id=\"1gxaktw\" data-start=\"1575\" data-end=\"1614\">Wide input voltage range (90V\u2013300V)<\/li>\n<li data-section-id=\"1tiqybn\" data-start=\"1615\" data-end=\"1660\">High-efficiency frequency conversion mode<\/li>\n<li data-section-id=\"10lve4d\" data-start=\"1661\" data-end=\"1685\">Generator compatible<\/li>\n<li data-section-id=\"h518v5\" data-start=\"1686\" data-end=\"1738\">Optional SNMP card with USB and RS232 monitoring<\/li>\n<li data-section-id=\"bra2oy\" data-start=\"1739\" data-end=\"1768\">User-friendly LCD display<\/li>\n<li data-section-id=\"19bn38f\" data-start=\"1769\" data-end=\"1799\">ECO mode for energy saving<\/li>\n<li data-section-id=\"1bt8fca\" data-start=\"1800\" data-end=\"1829\">Emergency Power Off (EPO)<\/li>\n<li data-section-id=\"1333d7s\" data-start=\"1830\" data-end=\"1870\">DSP-based digital control technology<\/li>\n<li data-section-id=\"1xb7hgc\" data-start=\"1871\" data-end=\"1913\">Built-in maintenance bypass (optional)<\/li>\n<li data-section-id=\"gr0z1w\" data-start=\"1914\" data-end=\"1955\">Intelligent battery management system<\/li>\n<li data-section-id=\"1grgsk9\" data-start=\"1956\" data-end=\"1990\">Optional isolation transformer<br \/>\nNotes<\/p>\n<ul data-start=\"2156\" data-end=\"2372\">\n<li data-section-id=\"1vep5yd\" data-start=\"2156\" data-end=\"2226\">For 1\u20133kVA UPS in frequency conversion mode, output derates to 80%<\/li>\n<li data-section-id=\"erhgvt\" data-start=\"2227\" data-end=\"2269\">At 208VAC output, power derates to 80%<\/li>\n<li data-section-id=\"4vgcrf\" data-start=\"2270\" data-end=\"2310\">Parallel redundancy is not supported<\/li>\n<li data-section-id=\"ak2n3a\" data-start=\"2311\" data-end=\"2372\">200\/208\/220\/230\/240VAC applies only to long backup models<\/li>\n<\/ul>\n<table>\n<thead>\n<tr>\n<th align=\"left\"><strong>Parameter<\/strong><\/th>\n<th align=\"left\"><strong>11-H1kVA<\/strong><\/th>\n<th align=\"left\"><strong>11-H2kVA<\/strong><\/th>\n<th align=\"left\"><strong>11-H3kVA<\/strong><\/th>\n<th align=\"left\"><strong>11-H6kVA<\/strong><\/th>\n<th align=\"left\"><strong>11-H10kVA<\/strong><\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td align=\"left\"><strong>Model<\/strong><\/td>\n<td align=\"left\">11-H1kVA<\/td>\n<td align=\"left\">11-H2kVA<\/td>\n<td align=\"left\">11-H3kVA<\/td>\n<td align=\"left\">11-H6kVA<\/td>\n<td align=\"left\">11-H10kVA<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Capacity<\/strong><\/td>\n<td align=\"left\">1000VA\/900W<\/td>\n<td align=\"left\">2000VA\/1800W<\/td>\n<td align=\"left\">3000VA\/2700W<\/td>\n<td align=\"left\">6000VA\/5400W<\/td>\n<td align=\"left\">10000VA\/9000W<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Input<\/strong><\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Phase<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{Single-phase, grounded}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{Single-phase, grounded}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Voltage Range<\/strong><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Lowest Transfer Voltage<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{160\/140\/120\/110VAC \u00b15% (Ambient temp &lt;35\u00b0C)<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>(Adjustable load ratio: 100%-80% \/ 80%-70% \/ 70%-60% \/ 60%-0)}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{50% load: 110VAC \u00b13%<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>100% load: 176VAC \u00b13%}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Lowest Restore Voltage<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{195\/175\/155\/135VAC \u00b15% (Ambient temp &lt;35\u00b0C)<\/p>\n<div class=\"container-Uxvbjy md-box-line-break wrapper-GYqxgQ undefined\"><\/div>\n<p>(Adjustable load ratio: 100%-80% \/ 80%-70% \/ 70%-60% \/ 60%-0)}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{Lowest transfer voltage +10V}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Highest Transfer Voltage<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{300VAC \u00b15%}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{300VAC \u00b13%}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Highest Restore Voltage<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{290VAC \u00b15%}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{Highest transfer voltage -10V}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Frequency Range<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{40Hz~70Hz}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{46Hz~54Hz @ 50Hz system; 56Hz~64Hz @ 60Hz system}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Power Specifications<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{\u22640.99 @ 220-230VAC (input voltage)}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{N\/A}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Output<\/strong><\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Output Voltage<\/td>\n<td align=\"left\">\\multicolumn{5}{c}{208\/220\/230\/240VAC \u00b11%}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Mains Voltage Range (Battery Mode)<\/td>\n<td align=\"left\">\\multicolumn{5}{c}{\u00b11%}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Frequency Range (Synchronization Range)<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{47-53Hz or 57-63Hz}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{46-54Hz or 56-64Hz}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Frequency Range (Battery Mode)<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{50\u00b10.25Hz or 60\u00b10.3Hz}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{50\u00b10.1Hz or 60\u00b10.1Hz}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Crest Factor<\/td>\n<td align=\"left\">\\multicolumn{5}{c}{3:1}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Harmonic Distortion<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{\u22643% THD (linear load); \u22646% THD (non-linear load)}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{\u22643% THD (linear load); \u22645% THD (non-linear load)}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Overload Capacity<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{Ambient temp &lt;35\u00b0C: 105%-110%: UPS shuts down after 10s in battery mode; transfers to bypass when mains is restored. 110%-130%: UPS shuts down after 3s in battery mode; transfers to bypass when mains is restored. &gt;150%: UPS shuts down immediately.}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{100%-110%: 30 minutes; 110%-130%: 5 minutes; &gt;130%: 10 seconds}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Transfer Time<\/strong><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Mains to Battery<\/td>\n<td align=\"left\">\\multicolumn{5}{c}{0ms}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Inverter to Bypass<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{4ms (standard conditions)}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{0ms}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Waveform (Battery Mode)<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{Pure sine wave}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{N\/A}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Efficiency<\/strong><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Mains Mode<\/td>\n<td align=\"left\">88%<\/td>\n<td align=\"left\">89%<\/td>\n<td align=\"left\">90%<\/td>\n<td align=\"left\">92%<\/td>\n<td align=\"left\">93%<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Battery Mode<\/td>\n<td align=\"left\">83%<\/td>\n<td align=\"left\">87%<\/td>\n<td align=\"left\">88%<\/td>\n<td align=\"left\">90%<\/td>\n<td align=\"left\">91%<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Battery<\/strong><\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Standard Model (S)<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Battery Model<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{12V\/7Ah}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{12V\/7Ah}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Quantity<\/td>\n<td align=\"left\">2<\/td>\n<td align=\"left\">4<\/td>\n<td align=\"left\">6<\/td>\n<td align=\"left\">12<\/td>\n<td align=\"left\">16<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Charging Current<\/td>\n<td align=\"left\">1.0A<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\">\\multicolumn{2}{c}{Preset: 1.0A \u00b110%, Max: 1A\/2A}<\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Long Backup Model (L)<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Battery Model<\/td>\n<td align=\"left\">\\multicolumn{5}{c}{12V\/AH (varies by application)}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Quantity<\/td>\n<td align=\"left\">3<\/td>\n<td align=\"left\">6<\/td>\n<td align=\"left\">8<\/td>\n<td align=\"left\">16<\/td>\n<td align=\"left\">16<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Charging Current<\/td>\n<td align=\"left\">1A\/2A\/4A\/6A<\/td>\n<td align=\"left\">1A\/2A\/4A\/6A<\/td>\n<td align=\"left\">1A\/2A\/4A\/6A<\/td>\n<td align=\"left\">1A\/2A\/4A\/6A (adjustable; 6A only for 16-section batteries)<\/td>\n<td align=\"left\">1A\/2A\/4A\/6A (adjustable; 6A only for 16-section batteries)<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Physical Performance<\/strong><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Standard Model<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Dimensions: D\u00d7W\u00d7H (mm)<\/td>\n<td align=\"left\">282\u00d7145\u00d7220<\/td>\n<td align=\"left\">397\u00d7145\u00d7220<\/td>\n<td align=\"left\">421\u00d7190\u00d7318<\/td>\n<td align=\"left\">369\u00d7190\u00d7688<\/td>\n<td align=\"left\">442\u00d7190\u00d7688<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Net Weight (kg)<\/td>\n<td align=\"left\">9.8<\/td>\n<td align=\"left\">17<\/td>\n<td align=\"left\">26.2<\/td>\n<td align=\"left\">51<\/td>\n<td align=\"left\">55<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Long Backup Model<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Dimensions: D\u00d7W\u00d7H (mm)<\/td>\n<td align=\"left\">282\u00d7145\u00d7220<\/td>\n<td align=\"left\">397\u00d7145\u00d7220<\/td>\n<td align=\"left\">421\u00d7190\u00d7318<\/td>\n<td align=\"left\">369\u00d7190\u00d7318<\/td>\n<td align=\"left\">442\u00d7190\u00d7318<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Net Weight (kg)<\/td>\n<td align=\"left\">4.4<\/td>\n<td align=\"left\">6.8<\/td>\n<td align=\"left\">7.4<\/td>\n<td align=\"left\">12<\/td>\n<td align=\"left\">15<\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Operating Environment<\/strong><\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Operating Humidity<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{20-90% RH, 0-40\u00b0C (non-condensing)}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{&lt;95% RH, non-condensing}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Noise<\/td>\n<td align=\"left\">&lt;50dB @ 1m<\/td>\n<td align=\"left\">&lt;50dB @ 1m<\/td>\n<td align=\"left\">&lt;50dB @ 1m<\/td>\n<td align=\"left\">&lt;55dB @ 1m<\/td>\n<td align=\"left\">&lt;58dB @ 1m<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Operating Temperature<\/td>\n<td align=\"left\">\\multicolumn{3}{c}{N\/A}<\/td>\n<td align=\"left\">\\multicolumn{2}{c}{0~40\u00b0C (battery life shortened above 25\u00b0C)}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\"><strong>Control &amp; Management<\/strong><\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<td align=\"left\">&#8212;<\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Smart RS-232\/USB<\/td>\n<td align=\"left\">\\multicolumn{5}{c}{Supports Windows 2000\/2003\/XP\/Vista\/2008, Windows 7\/8, Linux and MAC}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<tr>\n<td align=\"left\">Optional SNMP Card<\/td>\n<td align=\"left\">\\multicolumn{5}{c}{Supports SNMP and network management}<\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<td align=\"left\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-175\" src=\"http:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205.jpg\" alt=\"\" width=\"925\" height=\"591\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205.jpg 925w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-600x383.jpg 600w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-300x192.jpg 300w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/04\/editor_1777281398205-768x491.jpg 768w\" sizes=\"auto, (max-width: 925px) 100vw, 925px\" \/><\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>The 11-H 2kVA Online UPS features double conversion technology to deliver reliable power protection for office equipment, telecom systems, and small data centers. It offers high efficiency and intelligent battery management.<\/p>","protected":false},"featured_media":173,"comment_status":"open","ping_status":"closed","template":"","meta":{"_crdt_document":""},"product_brand":[46],"product_cat":[102,98,97],"product_tag":[473,477,118,117,481,475,465,479],"class_list":["post-766","product","type-product","status-publish","has-post-thumbnail","product_brand-szdxzh","product_cat-hf-1-1-phase-ups","product_cat-high-frequency-ups","product_cat-ups-solutions","product_tag-2kva-ups","product_tag-backup-power-supply","product_tag-double-conversion-ups","product_tag-online-ups","product_tag-power-protection","product_tag-small-ups-system","product_tag-uninterruptible-power-supply","product_tag-ups-for-office","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/id\/wp-json\/wp\/v2\/product\/766","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/id\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/id\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/id\/wp-json\/wp\/v2\/comments?post=766"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/id\/wp-json\/wp\/v2\/media\/173"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/id\/wp-json\/wp\/v2\/media?parent=766"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/id\/wp-json\/wp\/v2\/product_brand?post=766"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/id\/wp-json\/wp\/v2\/product_cat?post=766"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/id\/wp-json\/wp\/v2\/product_tag?post=766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}