{"id":3020,"date":"2026-08-02T15:28:46","date_gmt":"2026-08-02T15:28:46","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=3020"},"modified":"2026-08-17T20:02:47","modified_gmt":"2026-08-17T12:02:47","slug":"daxin-rm33-90kva-system-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/fr\/product\/daxin-rm33-90kva-system-ups\/","title":{"rendered":"90kVA Modular Online UPS | DAXIN RM33"},"content":{"rendered":"<h2>What Is the DAXIN RM33 90kVA Modular Online UPS?<\/h2>\n<p>The DAXIN RM33 90kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.<\/p>\n<p>Its modular architecture integrates power modules, centralized control, protection and service access within a scalable UPS platform, allowing system capacity and battery configuration to be planned according to project requirements.<\/p>\n<p>The RM33 platform supports 3 \u00d7 380\/400\/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.<\/p>\n<p>Final power-module configuration, battery runtime, redundancy, bypass, communications and project accessories should be confirmed according to the connected load and approved DAXIN technical proposal.<\/p>\n<h2>DAXIN RM33-90kVA Key Specifications<\/h2>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tre<\/th>\n<th>Caract\u00e9ristiques techniques<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td><strong>Mod\u00e8le<\/strong><\/td>\n<td><strong>RM33-90kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>UPS Type<\/td>\n<td>Modular Online UPS<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td>Three-Phase Input \/ Three-Phase Output<\/td>\n<\/tr>\n<tr>\n<td>Cabinet Capacity<\/td>\n<td><strong>90kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Type de batterie<\/td>\n<td>External Battery Pack<\/td>\n<\/tr>\n<tr>\n<td>Battery Cabinet Capacity<\/td>\n<td><strong>30 kVA \/ 30 kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Optional Battery Cabinets<\/td>\n<td>Up to 3<\/td>\n<\/tr>\n<tr>\n<td>Parallel Battery Cabinets<\/td>\n<td>Up to 3<\/td>\n<\/tr>\n<tr>\n<td>Tension d'entr\u00e9e<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Fr\u00e9quence d'entr\u00e9e<\/td>\n<td>50\/60Hz Auto-Detect<\/td>\n<\/tr>\n<tr>\n<td>Plage de fr\u00e9quences d'entr\u00e9e<\/td>\n<td>40\u201370Hz<\/td>\n<\/tr>\n<tr>\n<td>Facteur de puissance d'entr\u00e9e<\/td>\n<td>\u22650.99 @ 100% Load<\/td>\n<\/tr>\n<tr>\n<td>Input Current THDi<\/td>\n<td>&lt;2% @ 100% Load<\/td>\n<\/tr>\n<tr>\n<td>Tension de sortie<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Static Voltage Stability<\/td>\n<td>\u2264\u00b10.3% Typical Load<\/td>\n<\/tr>\n<tr>\n<td>Dynamic Voltage Stability<\/td>\n<td>\u2264\u00b13% Typical Load<\/td>\n<\/tr>\n<tr>\n<td>Fr\u00e9quence de sortie<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>Gamme de fr\u00e9quences<\/td>\n<td>46\u201354Hz or 56\u201364Hz<\/td>\n<\/tr>\n<tr>\n<td>THD de sortie<\/td>\n<td>\u22641% Linear \/ \u22642% Non-linear<\/td>\n<\/tr>\n<tr>\n<td>Efficacit\u00e9<\/td>\n<td><strong>Jusqu'\u00e0 96,51 TP3T<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Max. Charge Current<\/td>\n<td><strong>8A<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td><strong>1100 \u00d7 514 \u00d7 763mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Poids net<\/td>\n<td><strong>73kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de fonctionnement<\/td>\n<td>0 \u00e0 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Humidit\u00e9 relative<\/td>\n<td>0\u201395%, Non-Condensing<\/td>\n<\/tr>\n<tr>\n<td>Altitude<\/td>\n<td>&lt;1000m at Rated Power<\/td>\n<\/tr>\n<tr>\n<td>Indice de protection<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td>Gestion du r\u00e9seau<\/td>\n<td>SNMP (en option)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><\/h2>\n<h2>Principaux avantages<\/h2>\n<ul>\n<li><strong>90kVA Modular UPS Platform:<\/strong>\u00a0Designed for scalable three-phase critical-power applications in data centers, telecom and industrial facilities.<\/li>\n<li><strong>Scalable Modular Architecture:<\/strong>\u00a0System configuration can be planned according to current critical load, redundancy requirements and future expansion.<\/li>\n<li><strong>Three-Phase Power Protection:<\/strong>\u00a0Supports 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/li>\n<li><strong>Low Input Harmonic Distortion:<\/strong>\u00a0Input current THDi below 2% at full load helps reduce upstream electrical impact.<\/li>\n<li><strong>High Input Power Factor:<\/strong>\u00a0Input power factor is at least 0.99 at 100% load.<\/li>\n<li><strong>High Efficiency:<\/strong>\u00a0System efficiency is specified at up to 96.5%.<\/li>\n<li><strong>Flexible Battery Configuration:<\/strong>\u00a0External battery systems can be engineered according to required backup runtime.<\/li>\n<li><strong>Remote Monitoring:<\/strong>\u00a0RS-232\/USB communication is supported, with optional SNMP network management.<\/li>\n<\/ul>\n<h2>What Is a Modular UPS System?<\/h2>\n<p>A modular UPS system uses multiple power modules within a common UPS architecture instead of relying on a single fixed-capacity power stage.<\/p>\n<p>This approach allows capacity, redundancy and maintenance strategy to be planned according to the critical load, required availability and future expansion.<\/p>\n<p>The DAXIN RM33 series combines modular power architecture, centralized control, external battery configurations and network-management options for scalable critical-power applications.<\/p>\n<h2>Who Needs a 90kVA Modular UPS?<\/h2>\n<p>A 90kVA-class modular UPS may be suitable for medium-sized critical-power applications that require three-phase online protection, scalable system architecture and external battery backup.<\/p>\n<p>Typical projects include data rooms, telecom facilities, industrial automation systems, enterprise IT infrastructure and other critical loads where future expansion or redundancy may need to be considered.<\/p>\n<p>Final UPS selection should be based on the actual load in kW and kVA, power factor, required redundancy, future expansion and battery autonomy rather than nominal UPS capacity alone.<\/p>\n<h2>90kVA vs 120kVA Modular UPS: Which Should You Choose?<\/h2>\n<p>Choose between a 90kVA and 120kVA modular UPS according to the actual critical load, required operating margin, redundancy architecture, expected future expansion and battery backup requirements.<\/p>\n<p>A 90kVA system may suit lower critical-load requirements, while a 120kVA-class system can provide additional capacity for larger loads or future growth. DAXIN ENERGY can review the load list and single-line diagram before recommending the appropriate RM33 configuration.<\/p>\n<h2>\nPr\u00e9sentations des produits et documentation technique<\/h2>\n<figure id=\"attachment_4953\" aria-describedby=\"caption-attachment-4953\" style=\"width: 836px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4953\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3.webp\" alt=\"DAXIN RM33 60-600kVA Modular Online UPS Technical Specifications\" width=\"836\" height=\"1880\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3.webp 836w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-133x300.webp 133w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-455x1024.webp 455w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-768x1727.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-683x1536.webp 683w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/CS-3-5x12.webp 5w\" sizes=\"auto, (max-width: 836px) 100vw, 836px\" \/><figcaption id=\"caption-attachment-4953\" class=\"wp-caption-text\">Technical specifications for the DAXIN RM33 60-600kVA three-phase modular online UPS series.<\/figcaption><\/figure>\n<figure class=\"wp-block-image size-full\"><figcaption>Product Close-Up for DAXIN RM33-90kVA Modular UPS System Cabinet.<\/figcaption><\/figure>\n<h2>Applications typiques<\/h2>\n<ul>\n<li>Centres de donn\u00e9es et salles de serveurs<\/li>\n<li>Telecom core facilities and network infrastructure<\/li>\n<li>Industrial automation and manufacturing plants<\/li>\n<li>Financial and banking facilities<\/li>\n<li>Healthcare and medical infrastructure<\/li>\n<li>Transportation and public infrastructure<\/li>\n<li>Enterprise IT facilities<\/li>\n<li>Other scalable mission-critical power systems<\/li>\n<\/ul>\n<h2>S\u00e9lection et planification du projet<\/h2>\n<p>Avant de passer commande, v\u00e9rifiez que la puissance nominale exacte, la phase d'entr\u00e9e\/sortie, la tension, la fr\u00e9quence, le facteur de puissance, la tension de la batterie, l'autonomie, le contournement, les communications, les dimensions, les limites environnementales et la m\u00e9thode d'installation correspondent bien au mod\u00e8le s\u00e9lectionn\u00e9 et aux plans du projet.<\/p>\n<h2>Foire aux questions<\/h2>\n<h3>Ce produit peut-il \u00eatre configur\u00e9 pour un projet sp\u00e9cifique ?<\/h3>\n<p>Oui. La configuration \u00e9lectrique, l'autonomie de la batterie, les syst\u00e8mes de communication, le contournement, la disposition des armoires et les accessoires du projet peuvent \u00eatre examin\u00e9s en fonction des exigences du site.<\/p>\n<h3>Les notes techniques sont-elles toutes communes \u00e0 l'ensemble de la s\u00e9rie ?<\/h3>\n<p>Non. Les caract\u00e9ristiques techniques et les fonctions varient selon le mod\u00e8le et la configuration. Veuillez vous r\u00e9f\u00e9rer \u00e0 la fiche technique sp\u00e9cifique au projet comme r\u00e9f\u00e9rence d\u00e9finitive.<\/p>\n<h3>DAXIN ENERGY peut-elle vous aider \u00e0 choisir un syst\u00e8me ?<\/h3>\n<p>Oui. Veuillez nous fournir la liste des charges, la phase et la tension, la dur\u00e9e de fonctionnement requise, l'objectif de redondance, les exigences en mati\u00e8re de communication et l'environnement d'installation.<\/p>\n<h2>Demander une configuration de projet<\/h2>\n<p>Envoyez-nous les donn\u00e9es de charge, le sch\u00e9ma unifilaire, le temps de secours requis et les conditions sur site afin de recevoir une proposition sur mesure concernant un onduleur ou une batterie.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"1ke6u8w\" data-start=\"8522\" data-end=\"8555\">What is the DAXIN RM33 90kVA?<\/h3>\n<p data-start=\"8557\" data-end=\"8675\">The DAXIN RM33 90kVA is a three-phase modular online UPS system designed for scalable critical-power applications.<\/p>\n<h3 data-section-id=\"zp921o\" data-start=\"8677\" data-end=\"8727\">What input and output voltage does it support?<\/h3>\n<p data-start=\"8729\" data-end=\"8815\">The reference specification lists 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/p>\n<h3 data-section-id=\"18hlpeq\" data-start=\"8817\" data-end=\"8862\">What are the input power factor and THDi?<\/h3>\n<p data-start=\"8864\" data-end=\"8986\">The reference specification lists an input power factor of at least 0.99 at full load and input current THDi below 2%.<\/p>\n<h3 data-section-id=\"1mnbhsg\" data-start=\"8988\" data-end=\"9033\">What is the efficiency of the RM33-90kVA?<\/h3>\n<p data-start=\"9035\" data-end=\"9145\">System efficiency is specified at up to 96.5%. Actual efficiency depends on load and system configuration.<\/p>\n<h3 data-section-id=\"1xhhnr9\" data-start=\"9147\" data-end=\"9191\">Does the RM33 support remote monitoring?<\/h3>\n<p data-start=\"9193\" data-end=\"9279\">Yes. RS-232\/USB communication is supported, with optional SNMP network management.<\/p>\n<h3 data-section-id=\"1sqk2ns\" data-start=\"9281\" data-end=\"9329\">Can the RM33-90kVA support future expansion?<\/h3>\n<p data-start=\"9331\" data-end=\"9512\">The modular architecture supports scalable system planning. Final expansion capacity, redundancy and battery configuration should be confirmed according to project requirements.<\/p>","protected":false},"excerpt":{"rendered":"<p>The DAXIN RM33 90kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom and industrial facilities. It supports 380\/400\/415VAC three-phase operation, external battery configurations, centralized control and optional SNMP monitoring, with system efficiency up to 96.5%.<\/p>","protected":false},"featured_media":4957,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,100],"product_tag":[],"class_list":["post-3020","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-ups-system-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product\/3020","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/comments?post=3020"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media\/4957"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media?parent=3020"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_brand?post=3020"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_cat?post=3020"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_tag?post=3020"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}