{"id":3015,"date":"2026-08-02T15:28:12","date_gmt":"2026-08-02T15:28:12","guid":{"rendered":"https:\/\/btrytech.com\/en\/?post_type=product&#038;p=3015"},"modified":"2026-08-17T17:17:25","modified_gmt":"2026-08-17T09:17:25","slug":"daxin-rm33-200kva-system-ups","status":"publish","type":"product","link":"https:\/\/btrytech.com\/fr\/product\/daxin-rm33-200kva-system-ups\/","title":{"rendered":"200kVA Modular Online UPS | DAXIN RM33"},"content":{"rendered":"<h2>What Is the DAXIN RM33 200kVA Modular Online UPS?<\/h2>\n<p>The DAXIN RM33 200kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom facilities, industrial plants and other mission-critical applications.<\/p>\n<p>Its modular cabinet architecture integrates power modules, system control, protection and service access within a scalable UPS platform. The reference configuration provides 200kW cabinet capacity and supports external battery packs for project-specific backup requirements.<\/p>\n<p>The RM33 series supports 3 \u00d7 380\/400\/415VAC three-phase input and output, an input power factor of at least 0.99 at full load, input current THDi below 2% and system efficiency up to 96.5%.<\/p>\n<p>Final installed capacity, power-module configuration, battery runtime, redundancy architecture, communications and project accessories should be confirmed against the approved DAXIN technical proposal.<\/p>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tre<\/th>\n<th>RM33-200kVA<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Mod\u00e8le<\/td>\n<td><strong>RM33-200kVA<\/strong><\/td>\n<\/tr>\n<tr>\n<td>UPS Type<\/td>\n<td>Modular Online UPS<\/td>\n<\/tr>\n<tr>\n<td>Phase<\/td>\n<td>Three-Phase Input \/ Three-Phase Output<\/td>\n<\/tr>\n<tr>\n<td>Cabinet Capacity<\/td>\n<td><strong>200kW<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Type de batterie<\/td>\n<td>External Battery Pack<\/td>\n<\/tr>\n<tr>\n<td>Battery Cabinet Capacity<\/td>\n<td>20kVA \/ 20kW<\/td>\n<\/tr>\n<tr>\n<td>Optional Battery Cabinets<\/td>\n<td>10<\/td>\n<\/tr>\n<tr>\n<td>Tension d'entr\u00e9e<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Fr\u00e9quence d'entr\u00e9e<\/td>\n<td>50\/60Hz Auto-Detect<\/td>\n<\/tr>\n<tr>\n<td>Plage de fr\u00e9quences d'entr\u00e9e<\/td>\n<td>40\u201370Hz<\/td>\n<\/tr>\n<tr>\n<td>Facteur de puissance d'entr\u00e9e<\/td>\n<td>\u22650.99 @ 100% Load<\/td>\n<\/tr>\n<tr>\n<td>Input Current THDi<\/td>\n<td>&lt;2% @ 100% Load<\/td>\n<\/tr>\n<tr>\n<td>Tension de sortie<\/td>\n<td>3 \u00d7 380\/400\/415VAC (3PH+N)<\/td>\n<\/tr>\n<tr>\n<td>Static Voltage Stability<\/td>\n<td>\u2264\u00b10.3% Typical Load<\/td>\n<\/tr>\n<tr>\n<td>Dynamic Voltage Stability<\/td>\n<td>\u2264\u00b13% Typical Load<\/td>\n<\/tr>\n<tr>\n<td>Fr\u00e9quence de sortie<\/td>\n<td>50\/60 Hz<\/td>\n<\/tr>\n<tr>\n<td>THD de sortie<\/td>\n<td>\u22641% Linear \/ \u22642% Non-linear<\/td>\n<\/tr>\n<tr>\n<td>Efficacit\u00e9<\/td>\n<td><strong>Jusqu'\u00e0 96,51 TP3T<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td><strong>1100 \u00d7 600 \u00d7 2010mm<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Poids net<\/td>\n<td><strong>282kg<\/strong><\/td>\n<\/tr>\n<tr>\n<td>Temp\u00e9rature de fonctionnement<\/td>\n<td>0 \u00e0 40 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Altitude<\/td>\n<td>&lt;1000m Rated Power<\/td>\n<\/tr>\n<tr>\n<td>Indice de protection<\/td>\n<td>IP20<\/td>\n<\/tr>\n<tr>\n<td>Communication<\/td>\n<td>RS-232 \/ USB<\/td>\n<\/tr>\n<tr>\n<td>Gestion du r\u00e9seau<\/td>\n<td>SNMP (en option)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<figure class=\"wp-block-image size-full\">\n<p><figure id=\"attachment_4939\" aria-describedby=\"caption-attachment-4939\" style=\"width: 812px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4939\" src=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp\" alt=\"DAXIN RM33 Modular Online UPS Technical Specifications\" width=\"812\" height=\"1935\" srcset=\"https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1.webp 812w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-126x300.webp 126w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-430x1024.webp 430w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-768x1830.webp 768w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-645x1536.webp 645w, https:\/\/btrytech.com\/wp-content\/uploads\/2026\/08\/RM33-210kVA-CX-1-5x12.webp 5w\" sizes=\"auto, (max-width: 812px) 100vw, 812px\" \/><figcaption id=\"caption-attachment-4939\" class=\"wp-caption-text\">Technical specifications for the DAXIN RM33 three-phase modular online UPS series.<\/figcaption><\/figure><figcaption>Product View for DAXIN RM33-200kVA Modular UPS System Cabinet.<\/figcaption><\/figure>\n<h2>Principaux avantages<\/h2>\n<ul>\n<li><strong>Scalable Modular Architecture:<\/strong>\u00a0Modular UPS design supports flexible capacity planning and future system expansion.<\/li>\n<li><strong>200kW Cabinet Capacity:<\/strong>\u00a0The RM33-200kVA reference cabinet is designed for large three-phase critical-power applications.<\/li>\n<li><strong>Three-Phase Power Protection:<\/strong>\u00a0Supports 3 \u00d7 380\/400\/415VAC three-phase input and output for data center, telecom and industrial electrical systems.<\/li>\n<li><strong>Low Input Harmonic Distortion:<\/strong>\u00a0Input current THDi below 2% at full load helps reduce upstream electrical impact.<\/li>\n<li><strong>High Input Power Factor:<\/strong>\u00a0Input power factor is at least 0.99 at 100% load.<\/li>\n<li><strong>High Efficiency:<\/strong>\u00a0System efficiency is specified at up to 96.5%.<\/li>\n<li><strong>External Battery Configuration:<\/strong>\u00a0Battery systems can be engineered according to required backup runtime and project requirements.<\/li>\n<li><strong>Remote Monitoring:<\/strong>\u00a0RS-232\/USB communication is supported, with optional SNMP network management.<\/li>\n<\/ul>\n<h2><\/h2>\n<h2>What Is a Modular UPS System?<\/h2>\n<p>A modular UPS system uses multiple power modules within a common cabinet architecture instead of relying on a single fixed-capacity power stage.<\/p>\n<p>This approach allows UPS capacity, maintenance strategy and redundancy architecture to be planned according to the critical load and future expansion requirements.<\/p>\n<p>The DAXIN RM33 series combines modular power architecture with centralized control, external battery systems and network-management options for scalable critical-power applications.<\/p>\n<h2>Why Choose a 200kVA Modular UPS for a Data Center?<\/h2>\n<p>A modular UPS can help data center operators align installed power capacity with the actual critical load while preserving a path for future expansion and redundancy planning.<\/p>\n<p>The DAXIN RM33-200kVA combines three-phase online power protection, modular system architecture, external battery configuration and optional network monitoring for data center and mission-critical infrastructure applications.<\/p>\n<p>Final system sizing should consider the IT load in kW and kVA, power factor, redundancy target, expected expansion, required battery autonomy and upstream electrical architecture.<\/p>\n<h2>Applications typiques<\/h2>\n<ul>\n<li>Centres de donn\u00e9es et salles de serveurs<\/li>\n<li>Telecom core facilities and network infrastructure<\/li>\n<li>Industrial automation and manufacturing plants<\/li>\n<li>Financial and banking facilities<\/li>\n<li>Healthcare and medical infrastructure<\/li>\n<li>Transportation and public infrastructure<\/li>\n<li>Enterprise IT facilities<\/li>\n<li>Other scalable mission-critical power systems<\/li>\n<\/ul>\n<h2>S\u00e9lection et planification du projet<\/h2>\n<p>Avant de passer commande, v\u00e9rifiez que la puissance nominale exacte, la phase d'entr\u00e9e\/sortie, la tension, la fr\u00e9quence, le facteur de puissance, la tension de la batterie, l'autonomie, le contournement, les communications, les dimensions, les limites environnementales et la m\u00e9thode d'installation correspondent bien au mod\u00e8le s\u00e9lectionn\u00e9 et aux plans du projet.<\/p>\n<h2>Foire aux questions<\/h2>\n<h3>Ce produit peut-il \u00eatre configur\u00e9 pour un projet sp\u00e9cifique ?<\/h3>\n<p>Oui. La configuration \u00e9lectrique, l'autonomie de la batterie, les syst\u00e8mes de communication, le contournement, la disposition des armoires et les accessoires du projet peuvent \u00eatre examin\u00e9s en fonction des exigences du site.<\/p>\n<h3>Les notes techniques sont-elles toutes communes \u00e0 l'ensemble de la s\u00e9rie ?<\/h3>\n<p>Non. Les caract\u00e9ristiques techniques et les fonctions varient selon le mod\u00e8le et la configuration. Veuillez vous r\u00e9f\u00e9rer \u00e0 la fiche technique sp\u00e9cifique au projet comme r\u00e9f\u00e9rence d\u00e9finitive.<\/p>\n<h3>DAXIN ENERGY peut-elle vous aider \u00e0 choisir un syst\u00e8me ?<\/h3>\n<p>Oui. Veuillez nous fournir la liste des charges, la phase et la tension, la dur\u00e9e de fonctionnement requise, l'objectif de redondance, les exigences en mati\u00e8re de communication et l'environnement d'installation.<\/p>\n<h2>Demander une configuration de projet<\/h2>\n<p>Envoyez-nous les donn\u00e9es de charge, le sch\u00e9ma unifilaire, le temps de secours requis et les conditions sur site afin de recevoir une proposition sur mesure concernant un onduleur ou une batterie.<\/p>\n<h3 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"5difiu\" data-start=\"8307\" data-end=\"8341\">What is the DAXIN RM33-200kVA?<\/h3>\n<blockquote data-start=\"8343\" data-end=\"8460\">\n<p data-start=\"8345\" data-end=\"8460\">The DAXIN RM33-200kVA is a three-phase modular online UPS system designed for scalable critical-power applications.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"152my1e\" data-start=\"8462\" data-end=\"8495\">What is the cabinet capacity?<\/h3>\n<blockquote data-start=\"8497\" data-end=\"8601\">\n<p data-start=\"8499\" data-end=\"8601\">The supplied RM33 series specification lists 200kW cabinet capacity for the RM33-200kVA configuration.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"zp921o\" data-start=\"8603\" data-end=\"8653\">What input and output voltage does it support?<\/h3>\n<blockquote data-start=\"8655\" data-end=\"8739\">\n<p data-start=\"8657\" data-end=\"8739\">The reference specification lists 3 \u00d7 380\/400\/415VAC three-phase input and output.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"18hlpeq\" data-start=\"8741\" data-end=\"8786\">What are the input power factor and THDi?<\/h3>\n<blockquote data-start=\"8788\" data-end=\"8908\">\n<p data-start=\"8790\" data-end=\"8908\">The reference specification lists an input power factor of at least 0.99 at full load and input current THDi below 2%.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"1xhhnr9\" data-start=\"8910\" data-end=\"8954\">Does the RM33 support remote monitoring?<\/h3>\n<blockquote data-start=\"8956\" data-end=\"9056\">\n<p data-start=\"8958\" data-end=\"9056\">Yes. RS-232\/USB communication is supported, and SNMP network management is available as an option.<\/p>\n<\/blockquote>\n<h3 data-section-id=\"16gc40b\" data-start=\"9058\" data-end=\"9110\">How should the RM33-200kVA system be configured?<\/h3>\n<blockquote data-start=\"9112\" data-end=\"9306\">\n<p data-start=\"9114\" data-end=\"9306\">Final configuration should consider the critical load, required redundancy, future expansion, battery runtime, electrical distribution, communication requirements and installation environment.<\/p>\n<\/blockquote>","protected":false},"excerpt":{"rendered":"<p>The DAXIN RM33 200kVA is a three-phase modular online UPS system designed for scalable critical-power protection in data centers, telecom and industrial facilities. Its modular architecture supports flexible capacity planning, centralized control, external battery configurations and optional SNMP monitoring, with efficiency up to 96.5%.<\/p>","protected":false},"featured_media":4936,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[622,46],"product_cat":[97,100],"product_tag":[],"class_list":["post-3015","product","type-product","status-publish","has-post-thumbnail","product_brand-daxin-energy","product_brand-szdxzh","product_cat-ups-solutions","product_cat-ups-system-cabinets","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product\/3015","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/comments?post=3015"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media\/4936"}],"wp:attachment":[{"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/media?parent=3015"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_brand?post=3015"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_cat?post=3015"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/btrytech.com\/fr\/wp-json\/wp\/v2\/product_tag?post=3015"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}